Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 49 for “"Impressed current"”
-
Concrete Resistivity Impact on the Design of Impressed Current Cathodic Protection Systems
… development of guidelines and additions of the current Standard for the measurement of concrete resistivity via the Wenner probe in atmospheric conditions. Experiment 4 assesses the level of concrete resistivity increase over time for four commonly used repair mortars used in conjunction with …
-
Grout Acidification of Ribbon Anode in Impressed Current Cathodic Protection Systems in Concrete
Impressed current cathodic protection (ICCP) technology has been used for the corrosion protection of chloride contaminated reinforced concrete structures in Australia and globally for the past 30 - 40 years. Mixed Metal Oxide (MMO) Coated Titanium ribbon anode mesh has been the most widely used …
-
Copper load to the marine environment from Impressed Current Anti-Fouling (ICAF) systems
… methods to use, and one of the most common is Impressed Current Anti Fouling (ICAF). ICAF relies on electrolytic release of copper ions into the sea chest and seawater pipework. As mussel larvae are very sensitive to copper ions, the method is efficient to prevent growth inside the pipes. This …
-
Effectiveness of impressed current cathodic protection system on underground steel Engen refinery transfer lines system
… investigated to determine the effectiveness of impressed current cathodic protection (ICCP) on protecting Engen underground steel transfer lines from corrosion. These lines have a history of leaks aggravated by stray currents from a direct current (DC) traction system. The main challenge facing …
-
Intermittent impressed current corrosion protection of reinforced concrete using solar power to mitigate corrosion of reinforced concrete
… thesis investigates whether intermittent impressed current corrosion protection provides the same level of protection as a continuous impressed current system. A laboratory experiment evaluated four different impressed current levels (ranging from cathodic prevention to cathodic protection …
-
Design and testing of solar-powered impressed current cathodic protection devices for sustainable reinforcement steel corrosion mitigation in concrete structures
… prototyping, and testing of solar-powered impressed current cathodic protection (ICCP) devices integrating supercapacitors for efficient charge storage to combat corrosion of reinforcement steel in concrete structures. Alongside this focus, the study also emphasized the design and testing …
-
MECHANISM OF CONCRETE CRACKING IN SEAWATER DUE TO EMBEDDED METAL CORROSION
… and pH distribution within reinforced, impressed current specimens. Metal-concrete systems investigated included iron, molybdenum, cadmium, zinc, aluminum, copper, and nickel. Simplified models of the rebar corrosion process are presented in conjunction with electrochemical analysis of …
-
Feasibility of Cathodic Protection in Grouted Post Tensioned Tendons - Exploratory Model Calculations
… model is presented to explore feasibility of impressed current cathodic protection of strand in grouted tendons. The model examines polarization evolution as function of service time and includes consideration of anode placement and size, grout porosity, pore water alkalinity, electrochemical …
-
Galvanic cathodic protection of steel reinforcement using metallized zinc coatings.
… rate. This is accomplished by either an impressed current anode or a sacrificial anode in the system. The impressed current anode system, with metallized zinc as the anode material, has been used with success on a number of bridges. The sacrificial anode system has been used on a limited …
-
Cathodic polarization response of simulated prestressed concrete piles exposed to natural sea water
… to facilitate measurement of cathodic protection current. Conductive rubber in an impressed current system was used as the anode material. The specimens were initially freely corroded and then cathodically polarized at a constant current ranging from 0.5 to 1 mA/m$\sp2$ which corresponded to …
-
Correlation between Electrochemical Impedance Spectroscopy and LCR parameter meter in the corrosion processes of steel-reinforced mortars
… accelerated corrosion processes such as the impressed current method (6 and 12 hours) and carbonation chamber exposure (15 and 30 days), with some specimens subjected to both methods. EIS was used to measure the specimens, with results adjusted by the chosen equivalent circuit. Additionally, …
-
Data Analysis of the Long-Term Residual Effect of Cathodic Protection on Reinforced Concrete Structures
The application of impressed current cathodic protection (CP) is a well-established technology for the corrosion protection of reinforced concrete structures situated in marine environments. While the protective benefits of cathodic protection are well known, the after-effects following long …
-
CORROSION INDUCED CRACKING IN CONCRETE
… of steel embedded in mortar/concrete by impressed current. An attempt was made through this accelerated corrosion test to determine the inter-relationship between mortar quality, cover thickness and bar size on the intensity of corrosion to cause cracking. Other parameters such as the …
-
PROPERTIES OF CALCAREOUS DEPOSITS FORMED ON METAL SURFACE IN SEA WATER UNDER CATHODIC PROTECTION AT DIFFERENT POTENTIALS AND CURRENT DENSITIES
The influence of impressed current density and potential upon the nature of calcareous deposits formed . on a cathodic steel surface has been investigated. The experiments included potentiostatic, galvanostatic and mixed mode combined galvanostatic and potentiostatic techniques for affecting …
-
Dual function carbon fibre reinforced anode system for concrete structures.
… of CP by utilising the carbon fibre (CF) as an impressed current cathodic protection (ICCP) anode.The effect of anodic current density on the simulation of corrosion of steel in concrete has been investigated to allow specimens to be pre-corroded to a defined level prior to receiving the new …
-
Μελέτη της επίδρασης της βλάβης διάβρωσης στη μηχανική συμπεριφορά του χάλυβα οπλισμού σκυροδέματος
… The methods used were salt spray chamber and impressed current density technique. Exposure conditions XS1, according to EN206 standard, were simulated for both corrosion methods. Bare and semi-embedded specimens were exposed to the corrosive media. The aim was to study the effect of the …
-
Cathodic Protection of Corroded Pre-stressed Tendons
… of pre-stressed steel tendon exposed to an impressed current cathodic protection (ICCP) at varying potentials on a long-term basis to establish its effect on strength and establish optimised criteria for CP that can be safely applied to deteriorated pre-stressed structures. Twelve timber …
-
Metallic Coatings as Peripheral Barriers to Diminish the Adverse Effects of Cathodic Protection on Prestressing Members
… initiation of corrosion pits. But, the use of an impressed current system can cause hydrogen evolution at extreme negative potentials leading to brittle cracks in high-strength steel wires. Herein is documented a history of the utilization of cathodic protection in reinforced and prestressed …