Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 72 for “"Index Matching"”.

  1. Improved Reconstruction techniques with the Aid of Ray Tracing for Refractive Index Matching Free Optical Projection Tomography

    … target object in a material with a refractive index closely matched to that of the object. Nevertheless, the index-matching materials used for diamonds are often toxic, complicating operational procedures and limiting the wider application of OPT within the industry. Therefore, this study aimed …

    anu Repository record for Improved Reconstruction techniques with the Aid of Ray Tracing for Refractive Index Matching Free Optical Projection Tomography (opens in a new tab)

  2. Turbulent interactions between stream flow and near-subsurface flow: a laboratory approach using particle image velocimetry and refractive index matching

    … particle image velocimetry (PIV) and refractive index matching (RIM). This combination allows for detailed examination of flow fields both in the near-bed region and within the pore spaces at two flow Reynolds numbers. In additional experiments, a channel-spanning cylinder and a single spherical …

    uiuc Repository record for Turbulent interactions between stream flow and near-subsurface flow: a laboratory approach using particle image velocimetry and refractive index matching (opens in a new tab)

  3. Electrooptic light modulator with improved response linearity using optical feedback

    … level was altered by applying refractive index-matching liquid to one or both ends of the waveguide at the edges of the crystal. It was found that a high degree of response linearity in the presence of feedback was achievable at certain substrate temperatures. The spurious-free dynamic …

    tamu Repository record for Electrooptic light modulator with improved response linearity using optical feedback (opens in a new tab)

  4. Scalable Volumetric Three-dimensional Up-conversion Display Medium

    … earth doped fluoride crystals in a refractive index-matched polymer matrix. Detailed experiments are described to prepare such a scalable display medium using a wide variety of polymers. The scattering problem in such a medium was greatly reduced by index-matching the polymer to the crystalline …

    ucf Repository record for Scalable Volumetric Three-dimensional Up-conversion Display Medium (opens in a new tab)

  5. OLEDs: Improved light extraction through patterned plastics

    … when the substrate losses were extracted with index matching fluid. Pitches of 2.8µm and 7.8µm were patterned into PET/CAB substrates and EQEs of >30% were found for blue OLEDs on these substrates. We also studied the effect of high index planarization of various corrugations on device …

    iastate Repository record for OLEDs: Improved light extraction through patterned plastics (opens in a new tab)

  6. Left Ventricle Assist Device

    … further emphasized the importance of refractive index matching to perform particle image velocity. Matching the refractive index of the phantom with the medium is critical to avoid distortion and refraction of the light. Glycerol water was found to be an effective medium for refractive index …

    vt Repository record for Left Ventricle Assist Device (opens in a new tab)

  7. Design of a solid tank prototype optical computed tomography scanner

    … to address artifacts related to color and index matching baths that are often found with OCT for gel dosimeters. As a result of the solid tank design there is lensing that the fan-beam experiences while passing through a gel dosimeter, this lensing makes filtered back projection (FBP) less …

    ubc Repository record for Design of a solid tank prototype optical computed tomography scanner (opens in a new tab) Download PDF for Design of a solid tank prototype optical computed tomography scanner (opens in a new tab)

  8. Optofluidics for microscopy and sensing

    … plasmon resonance (SPR) sensor that exploits the index matching and coating capabilities of fluids. Conventional SPR sensor are implemented using an external light source, optical components to polarize incident light and guide light to and from a metal surface, a coupling device (such as a prism) …

    ubc Repository record for Optofluidics for microscopy and sensing (opens in a new tab) Download PDF for Optofluidics for microscopy and sensing (opens in a new tab)

  9. An integrated multiple capillary array electrophoresis system for high-throughput DNA sequencing

    … good focusing and immersing capillary array into index matching fluid. A side-entry excitation scheme with orthogonal detection was established for large capillary array. Two 100 capillary array formats were used for DNA sequencing. One format is cylindrical capillary with 150 [mu]m o.d., 75 [mu]m …

    iastate Repository record for An integrated multiple capillary array electrophoresis system for high-throughput DNA sequencing (opens in a new tab)

  10. Measurement of optical refractive index for 3d microcomponents /

    … where the understanding of the refractive index (RI) ofthe material is fundamental. Different techniques allows the measurements of the RI of thematerial but they limit the dimension of the structures to 2D. Two techniques are presentedfor RI measurements of 3D microelements fabricated by …

    vilnius Repository record for Measurement of optical refractive index for 3d microcomponents / (opens in a new tab)

  11. Study of transport and dissolution of a nonaqueous phase liquid in porous media: effects of low-frequency pulsations and surfactants

    … pore-scale in three dimensions using refractive index matching techniques along with planar laser induced fluorescence. The results yielded pore-scale information regarding ganglia volume, surface area, and position over time at various Capillary numbers. We found that with increasing Capillary …

    iastate Repository record for Study of transport and dissolution of a nonaqueous phase liquid in porous media: effects of low-frequency pulsations and surfactants (opens in a new tab)

  12. Computational Modeling of Optical Projection Tomographic Microscopy

    … such as degree of specimen staining, refractive index matching, and objective scanning. The computer simulation is used in conjunction with experimental methods to refine conclusions and improve system design in a robust methodology. While this work is currently driving improved microscope …

    washington Repository record for Computational Modeling of Optical Projection Tomographic Microscopy (opens in a new tab)

  13. On the modulation of low-order roughnesses on the flow over low-order topographies

    … particle image velocimetry in a refractive-index-matching channel at Reynolds numbers Re = 40,000, based on the channel half height and the bulk velocity. The topographies consisted on 2D and 3D sinusoidal waves, which spanned most of the test section. The roughnesses also consisted on the …

    uiuc Repository record for On the modulation of low-order roughnesses on the flow over low-order topographies (opens in a new tab)

  14. Multi-Modal Volumetric Imaging For Gemstone Inclusion Mapping

    … no special preparation is the high refractive index of diamonds. Optical methods such as optical coherence tomography are able to identify the various internal inclusions in rough diamonds, but they are unable to accurately locate their position due to the high refractive index of diamond. …

    anu Repository record for Multi-Modal Volumetric Imaging For Gemstone Inclusion Mapping (opens in a new tab)

  15. Transepidermal delivery and diffusion of optical skin clearing agents for reduction of light scattering in biological tissue and its clinical applications

    … believed to be a combination of dehydration and index matching. In order to capitalize on the non-invasive nature of light-tissue interactions for diagnostic and therapeutic purposes, hyper-osmotic optical clearing agents need to be delivered transepidermally. The first part of this dissertation …

    texas Repository record for Transepidermal delivery and diffusion of optical skin clearing agents for reduction of light scattering in biological tissue and its clinical applications (opens in a new tab)

  16. Building plasmonic crystals from plasmonic metamolecules /

    … environment as well as array geometry. While the index-matching has resulted in a sharper resonance, the redshift of the resonances have resulted in a lower energy confinement. We have also experimentally reported the angular dispersion of the surface lattice resonance in both square and …

    vilnius Repository record for Building plasmonic crystals from plasmonic metamolecules / (opens in a new tab)

  17. Integration of plasmonic nanostructures on waveguides

    … a symmetric organic cladding with a refractive index matching that of water, which increases the sensitivity by minimizing the stray light background and allows for the label-free detection of single nanoparticles. A protocol for the integration of plasmonic nanostructures on this waveguide was …

    chalmers Repository record for Integration of plasmonic nanostructures on waveguides (opens in a new tab)

  18. Turbulent Flows Generated by Multi-scale Structures - from a Fractal Tree to a Fractal Canopy

    … of an array of fractal tree models. An index-matching technique is utilized based on matching the refractive indices of the tree elements and the working fluid. Such index matching provides optical paths for both light illuminations and camera recordings. As a result, the flow fields …

    jhu Repository record for Turbulent Flows Generated by Multi-scale Structures - from a Fractal Tree to a Fractal Canopy (opens in a new tab)

  19. Novel encapsulation technologies for small size-scale self-healing applications

    … capsules scatter minimal light as a result of index matching. The capsules are capable of partially healing sub-micron damage in 100 μm PMMA films that have been mechanically damaged. The healed material scatters minimal light and retains the protective capabilities of the original PMMA …

    uiuc Repository record for Novel encapsulation technologies for small size-scale self-healing applications (opens in a new tab)

  20. AFM-based measurement of the mechanical properties of thin polymer films and determination of the optical path length of nearly index-matched cavities

    … optical path length within the gap of a nearly index-matching cavity based on coherent broadband interference was developed. In this method, the spectrum reflected for a cavity illuminated with a modelocked Ti:Sapphire laser was collected and analyzed using Fourier techniques. It was found that …

    texas Repository record for AFM-based measurement of the mechanical properties of thin polymer films and determination of the optical path length of nearly index-matched cavities (opens in a new tab)

Page 1 of 4