Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 138 for “"Indirect detection"”.
-
Constraining dark matter signals through indirect detection
… consider a specific candidate and describe the detection strategies for this case. In particular, we investigate the indirect detection method using gamma-ray lines produced by dark matter annihilation, which are one of the most robust and distinct signals of dark matter, providing a direct …
-
The Muon-Induced Neutron Indirect Detection EXperiment, MINIDEX
… The design of the Muon-Induced Neutron Indirect Detection EXperiment, MINIDEX, is presented and its installation and commissioning in the Tueubingen Shallow Underground Laboratory are described. Results from its first data taking period, run I, are presented. Muon-induced neutrons are …
-
Cosmic ray backgrounds for dark matter indirect detection
… is a key challenge for astroparticle physics. Indirect methods for their detection using high energy astro- physical probes such as cosmic rays have been much discussed. In particular, recent ‘excesses’ in cosmic ray electron and positron fluxes, as well as in microwave sky maps, have been …
-
Indirect detection of dark matter using gamma rays
… Massive Particle. Specifically, we analyze the indirect detection of Dark Matter through gamma-ray signals produced by particle annihilation. We discuss the key physical quantities governing this detection method, including the thermally averaged cross section, Dark Matter mass, energy spectrum, …
-
Indirect detection signals beyond the simplest supersymmetric dark matter
Indirect detection of gamma rays, neutrinos and charged cosmic rays from dark matter annihilation sheds light on the identity of dark matter and compliments direct detection and collider dark matter searches. By testing for the annihilation rate as well as the elastic scattering cross section of …
-
Indirect Detection of Axonal Architecture With Q-Space Imaging
Evaluating axon morphology would provide insights into connectivity, maturation, and disease pathology. Conventional diffusion MRI can provide metrics that are related to axon morphology, but cannot measure specific parameters such as mean axon diameter (MAD) and intracellular fraction (ICF). …
-
Novel techniques and prospects for the indirect detection of dark matter
… particle physics, and astrophysics. The indirect detection of dark matter through its annihilation products is sensitive to the dark matter mass, annihilation cross section, and coupling properties to the standard model. Notably, secondary gamma rays are expected from annihilating thermal …
-
Indirect detection of Bacillus anthracis (anthrax) using amplified gamma phage-based assays
Includes bibliographical references (pages 130-136).
-
Indirect Detection of Explosive Vapours by Thermal Dissociation Cavity Ring-Down Spectroscopy
This thesis describes two explosive detection methods capable of detecting explosives indirectly in ambient air. The first of the explosive detection methods utilizes a platinum catalyst heated to 350 °C to catalyze the thermal dissociation of nitroaromatic explosives, such as 2,4,6 trinitrotolune …
-
Gamma-ray emission from Galactic millisecond pulsars: Implications for dark matter indirect detection
The Fermi Large Area Telescope has observed a gamma-ray excess toward the center of the Galaxy at ~ GeV energies. The spectrum and intensity of the excess are consistent with the annihilation of dark matter with a mass of ~100 GeV and a velocity-averaged cross section of ~ 1e-26 cubic centimeter …
-
Indirect detection of selenium-77, tin-119, and tellurium-125 by nuclear magnetic resonance spectroscopy
… time on these compounds. In all cases the use of indirect detection substantially increased the sensitivity of observing these nuclei. Coupling constants between 9.4 and 54.2 Hz were successful on selenium compounds and coupling constants between 14.3 and 102.5 Hz were successful on model …
-
Automated Detection of Incomplete Exhalation as an Indirect Detection of Auto-PEEP on Mechanically Ventilated Adults
… of this dissertation is to develop an automated detection system of auto-PEEP through incomplete exhalation as revealed by ventilator graphics for mechanically ventilated adults. Auto-PEEP can cause adverse effects if allowed to linger and if not quickly identified. An automated detection system …
-
Neutron stars as laboratories for the nuclear matter equation of state and indirect detection of axions
Neutron stars are extreme objects that act as great cosmic laboratories for models of dense cold matter. The discovery of neutron stars with masses larger than two times that of our sun, combined with results about the nuclear equation of state below saturation, suggests that that the speed of …
-
A Novel SCP-RICM Assay Application: Indirect Detection of Analytes by Modulation of Protein-Protein Interactions
… interaction, here presented for the copper (Cu) detection. The detection of Cu was chosen as a proof-of-concept system. However, detecting metal ions is an essential endeavor because, in excessive amounts, they present a severe threat to health and the environment. The copper-dependent …
-
Pesticide Exposure Studies: Direct and Indirect Detection of Absorption of 2,4-D and Pronamide Herbicides in the Guinea Pig and Occupationally Exposed Workers
A simple high pressure liquid chromatography procedure was used to determine 2,4-D and pronamide exposure in spraymen and their dermal absorption and excretion in guinea pigs. Results of dermal application of these herbicides to guinea pigs demonstrated a strong correlation between the applied …
-
The impact of non-perturbative effects in dark matter production and detection
… matter as well as their impact on direct and indirect detection to attain insight on its fundamental nature. Specifically, we focus on Sommerfeld enhancement and the formation of dark matter bound states both of which can alter the total dark matter annihilation cross section and thus modify …
-
Dark Matter Annihilation and the Observed Positron Excess
… dark matter using two different methods: direct detection, in which a WIMP-like particle interacts with a detector in the laboratory, and indirect detection, in which products of dark matter annihilations such as neutrinos, gamma rays, and antimatter are detected. Recent results from two indirect …
-
Detection of Scalar Singlet Dark Matter
… results. Signals of the model from direct detection methods, indirect detection methods and from collider searches are all computed. Direct nuclear recoil signals are calculated and compared with current experimental bounds. Indirect cosmic ray annihilation signals in the form of gamma …
-
Indirect conductivity detection in size exclusion chromatography of small molecules
… a homogeneous response for all samples. Indirect detection methods have demonstrated to supply an alternative way to obtain a universal, sensitive and mass response in liquid chromatography. This research evaluated the indirect conductivity detection method for the size exclusion …
-
PPR imuninis jutiklis specifinių antikūnų prieš SARS-CoV-2 viruso RBD baltymą nustatymui /
… work was to develop a SPR immunosensor for the detection of specific antibodies against SARS-COV2-RBD protein using different detection formats. The applicability of SPR immunosensors of direct and two types of indirect detection formats for analyte detection was demonstrated. In the case of the …
Page 1 of 7