Results 1 to 11 of 11 for “"Indirect evaporative cooling"”

  1. The design evaluation of an improved indirect evaporative cooling system

    Energy efficient cooling systems are of particular interest in domestic and industrial applications today. The cost of energy has risen drastically in recent years and will probably continue to do so. To reduce cooling costs, conventional equipment must be made more efficient or new systems …

    ttu Repository record for The design evaluation of an improved indirect evaporative cooling system (opens in a new tab)

  2. Heat and Mass Transfer Characteristics of Indirect Evaporative Cooling System

    Indirect evaporative air coolers show good promise in extending the energy savings (compared with compression air conditioning system) from arid, low humidity areas to more widespread climatic conditions. However, no systematic experiment had been done concerning the effect of the wettability of …

    marquette Repository record for Heat and Mass Transfer Characteristics of Indirect Evaporative Cooling System (opens in a new tab)

  3. Applications of Maisotsenko cycle based indirect evaporative cooling technology in gas turbine power plants

    … are actively investigating a range of pre-cooling technologies with the objective of reducing intake air temperatures and enhancing GT performance. The objective of this research is to gain a deeper insight into the potential of M-cycle cooling technology to enhance the performance of a GT …

    adelaide Repository record for Applications of Maisotsenko cycle based indirect evaporative cooling technology in gas turbine power plants (opens in a new tab)

  4. Optimizing Produced Water Treatment in the Permian Basin: The Role of Indirect Evaporative Cooling in Hydraulic Fracturing

    This study investigates the novel application of Indirect Evaporative Cooling (IEC) for treating produced water in hydraulic fracturing operations within the Permian Basin. Utilizing a lab-scale IEC system, we conducted fifteen experiments to assess Total Dissolved Solids (TDS) and volume reduction …

    tamu Repository record for Optimizing Produced Water Treatment in the Permian Basin: The Role of Indirect Evaporative Cooling in Hydraulic Fracturing (opens in a new tab)

  5. Thermal Analysis of a Wet Plate Crossflow Heat Exchanger in an Air Conditioning Application

    … of crossflow heat exchangers, in the form of an indirect evaporative cooling (IEC). Based on the literature review, all studies concerning performance predictions have simplified the governing relationships of heat and mass transfer, which are interconnected by a Lewis factor (Lef). This research …

    unsw Repository record for Thermal Analysis of a Wet Plate Crossflow Heat Exchanger in an Air Conditioning Application (opens in a new tab) Embargoed

  6. COMPRESSOR-LESS WATER-BASED GREEN AIR-CONDITIONING SYSTEM

    … THE KEY COMPONENT IS A REGENERATIVE INDIRECT EVAPORATIVE HEAT EXCHANGER (IEHX). FIRST, AN EXPERIMENTAL STUDY WAS CONDUCTED AND EMPLOYED AS A BASIS FOR FURTHER MODEL VALIDATION AND SYSTEM OPTIMIZATION. NEXT, MATHEMATICAL MODELS HAVE BEEN DEVELOPED FOR EXPLORING THE FUNDAMENTAL CONCEPTS …

    nus Repository record for COMPRESSOR-LESS WATER-BASED GREEN AIR-CONDITIONING SYSTEM (opens in a new tab)

  7. Fundamental design and study of an evaporative cooling system

    In this study, the performance of a plate type indirect evaporative cooling system (IECS), based on cross-flow configuration, is numerically investigated. A two-dimensional model which considers variation of water film temperature and the wet channel wettability is developed to comprehensively …

    nus Repository record for Fundamental design and study of an evaporative cooling system (opens in a new tab)

  8. Transient & steady-state thermodynamic modeling of modular data centers

    … for modular data centers using four different cooling approaches: direct expansion cooling, direct and indirect evaporative cooling, and free air cooling. Furthermore, transient thermal response of these data centers to dynamic loads, such as varying server load through change in user …

    gatech Repository record for Transient & steady-state thermodynamic modeling of modular data centers (opens in a new tab)

  9. Combining a Building Integrated PVT System with a Low Temperature Desiccant Cooler to Drive Affordable Solar Cooling

    … (PVT) collector to drive a desiccant/indirect evaporative cooling (IEC) system. In this HVAC system, the PVT array supplies warm air to regenerate the desiccant wheel for cooling purpose or to provide space heating directly to the building, plus the electricity generated. Two building …

    unsw Repository record for Combining a Building Integrated PVT System with a Low Temperature Desiccant Cooler to Drive Affordable Solar Cooling (opens in a new tab)

  10. Investigation of the Maisotsenko Cycle Based Air Conditioning Systems

    Water evaporative based air coolers become more and more popular because of their lower energy consumption compared to the compressor-refrigerant based coolers. Low cooling capacity (theoretically wet-bulb temperature at 100% relative humidity), adding moisture to the product air and probable …

    adelaide Repository record for Investigation of the Maisotsenko Cycle Based Air Conditioning Systems (opens in a new tab)