  1. ac-Induced voltages in superconducting wires

    … he published it first) is applied to predict voltages induced in a wire carrying alternating current. Bean's model, which prescribes the distribution of current in a sample as a function of present conditions and history, has been applied by other experimenters to accurately forecast the …

    rice Repository record for ac-Induced voltages in superconducting wires (opens in a new tab)

  2. Lightning induced voltages in cables of power production centers

    Lorsqu’un bâtiment d’un centre de production d’électricité est frappé par la foudre, il se produit une dangereuse circulation de courants dans tous les composants connectés au bâtiment: les murs, le réseau de terre, et les câbles sortant du bâtiment. L’intérêt du présent travail est d’étudier les …

    star-france Repository record for Lightning induced voltages in cables of power production centers (opens in a new tab)

  3. Characterization of lightning induced voltages on overhead power lines

    … disturbance on power systems. The calculation of induced voltages, which is the propagated voltage surge on overhead power lines due to indirect lightning strokes, has been the subject of theoretical and experimental studies. The objective of this research is to develop a comprehensive numerical …

    njit Repository record for Characterization of lightning induced voltages on overhead power lines (opens in a new tab)

  4. Lightning Induced Voltages on Overhead Lines above Non-Uniform and Non-Homogeneous Ground

    Abstract: lightning induced voltages are one of the most common sources of failures on distribution networks operating in high lightning activity regions. Traditionally, the selection of insulation levels and protecting devices are carried out using statistical analysis based on typical values of …

    un-colombia Repository record for Lightning Induced Voltages on Overhead Lines above Non-Uniform and Non-Homogeneous Ground (opens in a new tab)

  5. Cálculo de campo electromagnético producido por rayo para terreno no plano y su efecto en las tensiones inducidas en líneas de distribución

    … a vertical lightning channel and the lightning induced voltages on distribution networks. The electromagnetic field is calculated solving the Maxwell equations in the different non flat terrain configurations, by means of the finite difference time domain method (FDTD), and the lightning induced …

    un-colombia Repository record for Cálculo de campo electromagnético producido por rayo para terreno no plano y su efecto en las tensiones inducidas en líneas de distribución (opens in a new tab)

  6. Statistical comparison of electromagnetic susceptibility of a transmission line in reverberation and semianechoic chambers

    … illuminated by a distant EMI source to study the induced voltages on the load impedance at one end. The frequency-domain responses are obtained. The statistical characteristics of the reverberation chamber, probability distribution function (PDF) and cumulative distribution function (CDF), are …

    ttu Repository record for Statistical comparison of electromagnetic susceptibility of a transmission line in reverberation and semianechoic chambers (opens in a new tab)

  7. A MICROPROCESSOR-BASED TELEPHONE CONTROLLER-INTERFACE

    … is analog in nature and susceptible to large induced voltages, thus making it incompatible with the digital logic signals and circuits of microprocessors. As a result, an interface must be provided between the controller and the telephone, both for the protection of the controller, and for the …

    sask Repository record for A MICROPROCESSOR-BASED TELEPHONE CONTROLLER-INTERFACE (opens in a new tab)

  8. A method for measuring the conductivity of high resistivity semiconductor materials

    … connected in series, in such a manner that the induced voltages tend to cancel. An approximate null in the secondary circuit is produced by positioning of the coils. A sample (usually small) of semiconductor material is placed between one pair of coils. A voltage proportional to the bulk …

    rice Repository record for A method for measuring the conductivity of high resistivity semiconductor materials (opens in a new tab)

  9. Calibration Of Magnetic Field Probes Using 3D Simulations

    … B-probes shielded in these ways, converting the induced voltages at their protected locations to meaningful magnetic field strength measurements. General Fusion, in pursuit of magnetized target fusion, requires B-probes shielded by metallic sheaths to be placed within recessed wells in the …

    queens Repository record for Calibration Of Magnetic Field Probes Using 3D Simulations (opens in a new tab)

  10. State-Plane Modelling and Control of a DFIG-based Wind Turbine

    … fixed to the stator of the machine induces large voltages in the rotor windings, leading to saturation of rotor converters and potential damage to the system. This work presents a novel dual-loop architecture to solve the stator flux transient, allowing the system to regain standard operation and …

    calgary Repository record for State-Plane Modelling and Control of a DFIG-based Wind Turbine (opens in a new tab)

  11. EMI/EMC analysis of electronic systems subject to near zone illuminations

    … line (TL) modes are extracted from the induced voltages. The resulting hybrid S-matrix allows for complete characterization of a microwave network in presence of enclosures or other scatterers. It can then be ported into a circuit solver for complex EMI/EMC analysis of electronic …

    ohiolink Repository record for EMI/EMC analysis of electronic systems subject to near zone illuminations (opens in a new tab)

  12. Models for electromagnetic coupling of lightning onto multiconductor cables in underground cavities

    … to predict electric fields within the mine and induced voltages on a cable that was left abandoned in the sealed area of the Sago mine. If voltages reached high enough levels, electrical arcing could have occurred from the abandoned cable. Electrical arcing is known to be an effective ignition …

    unm Repository record for Models for electromagnetic coupling of lightning onto multiconductor cables in underground cavities (opens in a new tab)

  13. DC-Side Transient Supression [i.e. suppression] Requirements for Photovoltaic Power Electronics

    Voltages induced by nearby lightning can create problems for systems involving power electronics. In photovoltaic (PY) systems, there are many conductors that become exposed to the electromagnetic pulse produced by a lightning strike. These conductors can act as antennas that receive the energy of …

    sdstate Repository record for DC-Side Transient Supression [i.e. suppression] Requirements for Photovoltaic Power Electronics (opens in a new tab)

  14. Design of a Vernier Permanent Magnet Wind Generator

    … such as high torque density, sinusoidal induced voltages and low torque ripple which makes it suitable for low-speed direct-drive wind applications. Additionally, its mechanical structure is as simple as a conventional permanent magnet (PM) machine, whilst eliminating the need for a …

    cape-town Repository record for Design of a Vernier Permanent Magnet Wind Generator (opens in a new tab)

  15. A Transmission Line Model for Active Implantable Medical Devices under MRI

    … and AIMDs. Such interaction can result in RF-induced heating in human tissues, which can cause tissue damage, and RF-induced voltages on devices, which can cause device damage or malfunction. When analyzing the MRI RF safety problems, full-wave electromagnetic simulation approaches are often …

    houston Repository record for A Transmission Line Model for Active Implantable Medical Devices under MRI (opens in a new tab)

  16. Continuously Variable Series Reactor Modeling and Application

    … various aspects of CVSR behavior, including the induced voltage across the DC winding, flux density within the core's branches, and the power exchange between the two circuits. These analyses, providing valuable insights into the performance and potential applications of CVSR technology within …

    ucf Repository record for Continuously Variable Series Reactor Modeling and Application (opens in a new tab)

  17. A Wave-Chaotic Approach To Predicting And Measuring Electromagnetic Field Quantities In Complicated Enclosures

    … to determine the shape and scales of induced voltages PDFs at specific points within complicated enclosures, such as computer boxes, when irradiated by high-intensity, short-wavelength electromagnetic energy. The insight gained from the experimental validation of the Random Coupling …

    maryland Repository record for A Wave-Chaotic Approach To Predicting And Measuring Electromagnetic Field Quantities In Complicated Enclosures (opens in a new tab)

  18. Electron beam sizes and lifetimes at MAX II and MAX III

    … of the longitudinal beam size and the induced voltages in the passive cavities agreed well with computer simulations of the triple RF system of MAX III. At high Landau cavity voltages a stable overstretched bunch shape with two regions of phase stability was observed. The lifetime …

    lund Repository record for Electron beam sizes and lifetimes at MAX II and MAX III (opens in a new tab)

  19. Artifacts denoising of EEG acquired during simultaneous EEG-FMRI

    … of EEG-fMRI.<br>EEG suffers primarily from induced voltages by fast changing gradients during MR imaging (gradient artifacts, GAs) and from physiological artifacts (mainly ballistocardiogram artifact, BCG). Due to their reproducible nature, they can often be eliminated by so-called …

    freiburg-diss Repository record for Artifacts denoising of EEG acquired during simultaneous EEG-FMRI (opens in a new tab)

  20. Modeling and experimental investigation of lightning arcs and overvoltages for medium voltage distribution lines

    In this dissertation, lightning overvoltages in Medium Voltage (MV) lines are thoroughly investigated. The other goal is to propose new protection schemes for the designs. The lines consist of overhead lines, underground cables and covered conductors. These overvoltage problems range from direct …

    aalto Repository record for Modeling and experimental investigation of lightning arcs and overvoltages for medium voltage distribution lines (opens in a new tab)