Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 19 of 19 for “"Induction coils"”

  1. Linear Electromagnetic Energy Scavenging Device Designed in Low Temperature Co-Fired Ceramics

    … parameters of the electromagnetic generator. The induction coils for the electromagnetic generator were fabricated in Low Temperature Co-Fired Ceramics (LTCC), taking advantage of the material system to produce a small high density package of coils. LTCC induction coils were found to be a viable …

    boise Repository record for Linear Electromagnetic Energy Scavenging Device Designed in Low Temperature Co-Fired Ceramics (opens in a new tab)

  2. Design of a ground-deployed sensor for detecting the sag of Overhead Transmission Lines by measurement of the magnetic field

    … an OTL. A sensor is developed that consists of induction coils. By measuring the voltage induced in the coils, and with prior knowledge of the geometries of the span, the sensor can deduce the line sag. The mathematical strategy employed by the sensor was developed through simulating the …

    reykjavik Repository record for Design of a ground-deployed sensor for detecting the sag of Overhead Transmission Lines by measurement of the magnetic field (opens in a new tab)

  3. Drying of granular materials using an induction heated double-screw conveyor

    … study of the drying of sand using an induction heated double-screw conveyor (screw shaft radius 0.0381 m, blade radius 0.0883 m, thread pitch 0.0869 m, heated length 1.96 m) is presented. The main aim was to improve the understanding of the operating characteristics of the dryer and …

    mcgill Repository record for Drying of granular materials using an induction heated double-screw conveyor (opens in a new tab)

  4. ANALYSIS AND IMPEDANCE-BASED DETECTION OF ELECTROMAGNETIC COIL INSULATION DEGRADATION

    Electromagnetic induction coils are widely used in a variety of applications, such as motors, solenoid valves, and relays. Many of these applications are safety-critical. Failure of the insulation that protects the windings in electromagnetic coils is a significant cause of coil failure and can …

    maryland Repository record for ANALYSIS AND IMPEDANCE-BASED DETECTION OF ELECTROMAGNETIC COIL INSULATION DEGRADATION (opens in a new tab)

  5. Calculation of array probe response to sub-surface corrosion using edge element

    … or so, new designs have emerged for excitation coils which has led to a need for new modeling schemes. There has been a trend towards the use of magnetic field sensors for the measurement of the scattered field from the conductor body as an alternative to induction coils. Along with the changes …

    iastate Repository record for Calculation of array probe response to sub-surface corrosion using edge element (opens in a new tab)

  6. Failure modes of an alumina-based machining ceramic

    … A test rig was designed for operation on an induction heater to simulate the condition of abrupt disengagement during machining. Failure thresholds were established for a variety of induction coils under closely controlled conditions of heatining and loading.

    middlesex Repository record for Failure modes of an alumina-based machining ceramic (opens in a new tab)

  7. Design, construction and testing of a computerized ignition circuit for an internal combustion engine

    … cylinders and sixteen pistons. The ignition coils with two high voltage outputs were used to ignite sixteen spark plugs on the system. They were driven by PIC16F628A based igniter circuits triggered with digital signals. The igniter circuits receive ignition signals in a square wave form from …

    metu Repository record for Design, construction and testing of a computerized ignition circuit for an internal combustion engine (opens in a new tab)

  8. Sensitivity Analysis of Three Assembly Procedures for a Bascule Bridge Fulcrum

    … uses a warm shrink fitting process whereby induction coils are placed on the girder of the bridge and heat is applied until sufficient thermal expansion of the girder hole allows for insertion of the hub component. All three assembly procedures use a cooling method at some stage of the …

    usf Repository record for Sensitivity Analysis of Three Assembly Procedures for a Bascule Bridge Fulcrum (opens in a new tab)

  9. Ion dynamics in a linear high field RFQ trap

    … resonating circuit design using hollow air-cored induction coils was used to simultaneously deliver the necessary RF and DC trapping potentials to the linear RFQ system as well as deliver the extraction voltages used to eject test ions (Cs+, m/z = 133) produced by a surface ionization source. The …

    mcgill Repository record for Ion dynamics in a linear high field RFQ trap (opens in a new tab)

  10. Electron Spin Resonance Magnetometers for Particle Accelerators

    … "markers"), field tracking sensors (called "induction coils"), an acquisition system, a control system that calculates the magnetic field from the sensors, and a distribution system that delivers the field value to the users. Due to the configuration of the CERN accelerator chain, if one of …

    epfl Repository record for Electron Spin Resonance Magnetometers for Particle Accelerators (opens in a new tab)

  11. Towards the Induction Welding of Complex, Curved Thermoplastic Composite Structures

    … manufacturing, providing a road map for the induction welding of complex curved aerostructures. The work presented in this thesis enhances the understanding of the induction welding process by deriving and leveraging coil geometric relationships to benefit the manufacturing of complex curved …

    south-carolina Repository record for Towards the Induction Welding of Complex, Curved Thermoplastic Composite Structures (opens in a new tab)

  12. Design and implementation of magnetic field sensors for biomedical applications /

    … are investigated. Then the air-cored induction coil sensor is chosen due to its advantages. Afterwards the usage of induction coils combined with amplifiers and connection types are studied. The biomedical applications requiring the use of magnetic field sensors are introduced. One of …

    metu Repository record for Design and implementation of magnetic field sensors for biomedical applications / (opens in a new tab)

  13. Optimization of thermal dose delivery in magnetic nanoparticle hyperthermia, using novel simulation tools

    … for simulations of magnetic fields generated by induction coils is described. Magnetic field simulations for two commercial systems are validated, and subsequently, a methodology is presented for the optimization and construction of an induction coil designed for an in-house ZVS system. In …

    patras-thes Repository record for Optimization of thermal dose delivery in magnetic nanoparticle hyperthermia, using novel simulation tools (opens in a new tab)

  14. Optimization of thermal dose delivery in magnetic nanoparticle hyperthermia, using novel simulation tools

    … for simulations of magnetic fields generated by induction coils is described. Magnetic field simulations for two commercial systems are validated, and subsequently, a methodology is presented for the optimization and construction of an induction coil designed for an in-house ZVS system. In …

    greece Repository record for Optimization of thermal dose delivery in magnetic nanoparticle hyperthermia, using novel simulation tools (opens in a new tab)

  15. Monolithic induction-sourced AC-to-DC power supply design

    … parameters of two VLSI-compatible square-shaped coils are calculated in both cases of perfect alignment and misalignment. All magnetic field and voltage transfer ratios in this thesis were programmed using Fortran language. This thesis concludes that the stagger-tuning circuit technique provides …

    njit Repository record for Monolithic induction-sourced AC-to-DC power supply design (opens in a new tab)