Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 68 for “"Induction generators."”.

  1. Transient Response of Induction Generators

    Made available in DSpace on 2014-12-04T21:02:50Z (GMT). No. of bitstreams: 1 0015188.pdf: 1089968 bytes, checksum: e2d0289c654f3cece341ef16171d419f (MD5) Previous issue date: 1955

    uiuc Repository record for Transient Response of Induction Generators (opens in a new tab)

  2. Protection of synchronous generators and induction generators

    … Protection) that can protect the synchronous generators and induction generators securely and dependably when they have internal faults. Specifically, the EBP function monitors the consistency between the generator measurements and the generator dynamic model via dynamic state estimation. Any …

    gatech Repository record for Protection of synchronous generators and induction generators (opens in a new tab)

  3. Bit-Stream Control of Doubly Fed Induction Generators

    … especially wind generation. The Doubly Fed Induction Generator (DFIG) is commonly used for wind generation applications as it allows for efficient operation of the wind turbine by varying the speed of the generator without resorting to the use of large power converters. A typical DFIG system …

    auckland-ms Repository record for Bit-Stream Control of Doubly Fed Induction Generators (opens in a new tab)

  4. Transient performance analysis of wind-power induction generators

    … wind energy conversion systems with a doubly fed induction generator (DFIG) was developed and experimentally validated. Short-term grid disturbance and ride-through analyses were carried out for a 1.7-MW DFIG wind-power conversion system. Two simulation models of the wind-power DFIG were compared …

    aalto Repository record for Transient performance analysis of wind-power induction generators (opens in a new tab)

  5. Fault Ride-through of Wind Parks with Induction Generators

    … ride-through. In this study, the wind turbine generators are selected to be fixed-speed induction generators without reactive power controllability. The studied wind park is made of one hundred and thirty 3MW wind turbine generators connected to a 20 kV collector system. This collector system …

    chalmers Repository record for Fault Ride-through of Wind Parks with Induction Generators (opens in a new tab)

  6. Multiple Three-Phase Induction Generators for Wind Energy Conversion Systems

    … ripple. This thesis examines use of a multiphase induction generator in wind energy conversion systems (WECS). In particular, multiphase generators that comprise multiple 3-phase winding sets, where each winding set is supplied using an independent 3-phase voltage source inverter (VSI), are …

    liverpool-jm Repository record for Multiple Three-Phase Induction Generators for Wind Energy Conversion Systems (opens in a new tab) Download PDF for Multiple Three-Phase Induction Generators for Wind Energy Conversion Systems (opens in a new tab)

  7. The Stability Analysis for Wind Turbines with Doubly Fed Induction Generators

    … (PI) controllers of a doubly fed induction generator (DFIG) driven by a wind turbine to increase the transient performance based on small signal stability analysis. Firstly, the impact of wind generation is introduced. The stability of power systems with wind generation is …

    nebraska Repository record for The Stability Analysis for Wind Turbines with Doubly Fed Induction Generators (opens in a new tab)

  8. Capacitance requirements for the operation of induction generators in isolated power systems

    Operation of an induction machine as a generator has been gaining ground in the last decades mainly because of its application in renewable nonconventional energy systems such as wind energy systems. One of the most popular applications of the induction generator is in isolated power systems with …

    texas Repository record for Capacitance requirements for the operation of induction generators in isolated power systems (opens in a new tab) Restricted access

  9. Optimal control of wind energy conversion systems with doubly-fed induction generators

    … energy resource. The WECS using a doubly-fed induction generator (DFIG) to convert mechanical power into electrical power has a significant advantage. This WECS requires a smaller power converter in comparison with a squirrel cage induction generator. Efficiency of the DFIG-WECS can be …

    birmingham Download PDF for Optimal control of wind energy conversion systems with doubly-fed induction generators (opens in a new tab)

  10. Induction generators in mini and micro hydro applications as a low cost alternative

    … with the chief concern of investigating induction generators as a viable alternative. A method of reconfiguring the static excitation of a self-excited induction generator is studied to supply a single-phase or an unbalanced three-phase load using a standard three-phase machine. This …

    auckland-ms Repository record for Induction generators in mini and micro hydro applications as a low cost alternative (opens in a new tab)

  11. Computer Modeling and Experimental Validation of Self-Excitation in Series-Connected Induction Generators

    … with opposite phase sequence, a series-connected induction machine is created. In order for this machine to become self-excited, the machine terminals must be connected in parallel with a three-phase capacitor bank. In this thesis, d-q theory and space vectors are applied to investigate the …

    boise Repository record for Computer Modeling and Experimental Validation of Self-Excitation in Series-Connected Induction Generators (opens in a new tab)

  12. The simulation of induction generators for microhydro systems: with application to developing countries

    The driving of an induction machine faster than its synchronous speed, causing it to generate electrical power, is described in most textbooks on electrical machines. The principle of self-excitation, by which an induction generator can be excited from static capacitors is not, however, obvious. …

    unsw Repository record for The simulation of induction generators for microhydro systems: with application to developing countries (opens in a new tab)

  13. Diagnosis and Isolation of Air Gap Eccentricities in Closed-loop Controlled Doubly-Fed Induction Generators

    With the widespread use of doubly-fed induction generators (DFIG) in wind energy conversion systems, condition monitoring is being given importance. Non-intrusive techniques like motor current signature analysis (MCSA), which involves looking for specific frequency components in the current …

    tamu Repository record for Diagnosis and Isolation of Air Gap Eccentricities in Closed-loop Controlled Doubly-Fed Induction Generators (opens in a new tab)

  14. The nature of double-fed induction generators for frequency and voltage support from wind turbines

    … To that point, it is shown here that double-fed induction generator wind turbines without well-designed frequency control can actually have a temporary load-rejecting response. Here, the connection of physical inertia and control design to frequency response is quantified with transfer functions …

    iastate Repository record for The nature of double-fed induction generators for frequency and voltage support from wind turbines (opens in a new tab)

  15. A general mathematical model of dispersed single phase induction generators employed within a three-phase distribution system

    … model is constructed of single-phase induction generators interacting with an adjacent three-phase distribution system. It is shown that this model is valid for describing the joint operation of an induction generator and distribution system. Model performance is illustrated initially …

    ut-knoxville Repository record for A general mathematical model of dispersed single phase induction generators employed within a three-phase distribution system (opens in a new tab)

  16. Utilizing reactive capability of doubly fed induction generators to enhance system voltage performance and withstand wind variability

    … technologies. Within the realm of wind generators, the Doubly Fed Induction Generator (DFIG) is the preferred choice of installation worldwide.</p> <p>Large scale penetration of wind energy in the system raises significant concerns regarding the reliability implications of the inherent …

    iastate Repository record for Utilizing reactive capability of doubly fed induction generators to enhance system voltage performance and withstand wind variability (opens in a new tab)

  17. Modeling of doubly-fed induction generators connected to distribution system based on eMEGASim® real-time digital simulator

    … bed for a wind farm composed of six doubly-fed induction generators (DFIGs) connected to a distribution system based on the OPAL-RT’s eMEGASim® real-time digital simulator. The system in this research consists of a 9 MW wind farm, an average SimpowerSystems® DFIG wind turbine, connected to a …

    utc Repository record for Modeling of doubly-fed induction generators connected to distribution system based on eMEGASim® real-time digital simulator (opens in a new tab)

Page 1 of 4