Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 37 for “"Inductively Coupled Plasma Spectrometry"”

  1. Application of artificial intelligence techniques for inductively coupled plasma spectrometry

    … for the automated analysis of samples by inductively coupled plasma (ICP) Spectrometry is presented. An expert system for diagnosing an ICP atomic emission spectrometry (AES) system using a blank solution was developed as a warning system. This expert system was able to warn the system of …

    mcgill Repository record for Application of artificial intelligence techniques for inductively coupled plasma spectrometry (opens in a new tab)

  2. Laser ablation for sample introduction in inductively coupled plasma spectrometry.

    … as a means of sample introduction for the Inductively Coupled Plasma (ICP). This involved the configuration of an ICP spectrometer, a laser and a novel laser ablation chamber. The latter offered the facility of electrothermally heating samples before or during laser ablation.Several …

    sheffield-hallam Repository record for Laser ablation for sample introduction in inductively coupled plasma spectrometry. (opens in a new tab)

  3. Field sampling and microcolumn preconcentration techniques in inductively coupled plasma spectrometry.

    … are subsequently eluted and quantified by inductively coupled plasma-emission spectrometry (ICP-ES).Initial studies focus on trace analytes in caesium iodide, however a selection of the alkali metal salts, lithium nitrate, potassium bromide, sodium fluoride and sodium chloride, are …

    sheffield-hallam Repository record for Field sampling and microcolumn preconcentration techniques in inductively coupled plasma spectrometry. (opens in a new tab)

  4. Sample preconcentration and analysis by direct sample insertion inductively coupled plasma spectrometry

    … by Direct Sample Insertion (DSI) into the Inductively Coupled Plasma (ICP) for ultra trace elemental analysis have been developed. A microcolumn based flow injection (FI) manifold was used with ICP Mass Spectrometry (MS) but performance was adversely affected by high and variable blank …

    mcgill Repository record for Sample preconcentration and analysis by direct sample insertion inductively coupled plasma spectrometry (opens in a new tab)

  5. Alternative Sample Introduction Techniques to Nebulization of Solutions in Inductively Coupled Plasma Spectrometry

    … alternative sample introduction techniques for inductively coupled plasma mass spectrometry (ICPMS) and optical emission spectrometry (ICPOES). This work was conducted as part of a Collaborative Research and Development project with Activation Laboratories Ltd., Ancaster, Ontario. 1. The first …

    queens Repository record for Alternative Sample Introduction Techniques to Nebulization of Solutions in Inductively Coupled Plasma Spectrometry (opens in a new tab)

  6. Development and application of thermal vaporization sample introduction techniques with demountable sample supports for inductively coupled plasma spectrometry

    … to thermal vaporization sample introduction for inductively coupled plasma (ICP) spectrometry using techniques with demountable sample supports are presented and compared. Developments and applications are presented for two sample introduction arrangements that use interchangeable sample probes …

    mcgill Repository record for Development and application of thermal vaporization sample introduction techniques with demountable sample supports for inductively coupled plasma spectrometry (opens in a new tab)

  7. APPLICATION OF INDUCTIVELY COUPLED PLASMA SPECTROMETRY TO THE DETERMINATION OF POTENTIALLY TOXIC ELEMENTS IN WHEAT AND MISWAK FROM SAUDI ARABIA

    … A method based on electrothermal vaporization coupled to inductively coupled plasma (ICP) optical emission spectrometry was developed for the direct analysis of miswak (natural toothbrush) in 77 s, as a first step in the risk assessment process. This method eliminates the need for digesting …

    queens Repository record for APPLICATION OF INDUCTIVELY COUPLED PLASMA SPECTROMETRY TO THE DETERMINATION OF POTENTIALLY TOXIC ELEMENTS IN WHEAT AND MISWAK FROM SAUDI ARABIA (opens in a new tab)

  8. Investigation of two solid sample introduction techniques for the analysis of biological, environmental, and pharmaceutical samples by inductively coupled plasma spectrometry

    … direct trace metals analysis of solid samples by inductively coupled plasma spectroscopy were investigated using laser ablation and thermal vaporization systems for solid sample introduction of biological, environmental, and pharmaceutical samples. Laser ablation with inductively coupled plasma …

    mcgill Repository record for Investigation of two solid sample introduction techniques for the analysis of biological, environmental, and pharmaceutical samples by inductively coupled plasma spectrometry (opens in a new tab)

  9. Inductively coupled plasma spectrometry: noise characteristics of aerosols, application of generalized standard additions method, and Mach disk as an emission source

    … on three problem areas in the performance of inductively coupled plasma (ICP) source;The noise characteristics of aerosols produced by ICP nebulizers are investigated. A laser beam is scattered by aerosol and detected by a photomultiplier tube and the noise amplitude spectrum of the scattered …

    iastate Repository record for Inductively coupled plasma spectrometry: noise characteristics of aerosols, application of generalized standard additions method, and Mach disk as an emission source (opens in a new tab)

  10. The investigation of high performance techniques and application to complex matrices using inductively coupled plasma spectrometry and the impact of urbanization on the Scioto River system

    … on the order of 0.1% (typically 5 - 10%) in inductively coupled plasma optical emission spectrometry (ICP-OES). All measurement error resulting from the instrument can essentially be removed limiting the concentration uncertainties to the precision on a balance. Matrix effects in ICP-OES as …

    ohiolink Repository record for The investigation of high performance techniques and application to complex matrices using inductively coupled plasma spectrometry and the impact of urbanization on the Scioto River system (opens in a new tab)

  11. Forensic, Archaeological and Related Application of Inductively Coupled Plasma Mass Spectrometry

    Inductively coupled plasma spectrometry (ICP-MS) is a powerful analytical instrument that can be applied to multiple disciplines for trace elements detection. In the first stage of this research, ICP-MS was used to group archaeological pottery sherds based on the compositional information obtained. …

    wvu Repository record for Forensic, Archaeological and Related Application of Inductively Coupled Plasma Mass Spectrometry (opens in a new tab)

  12. Récupération de métaux stratégiques issus de diodes électroluminescentes (DELs)

    … consisting of a quantitative analysis by inductively-coupled plasma spectrometry and a qualitative analysis by X-ray fluorescence spectrometry was carried out. Once the composition of the study material was known, several tests of leaching in sulphuric acid were conducted to assess the …

    liege Repository record for Récupération de métaux stratégiques issus de diodes électroluminescentes (DELs) (opens in a new tab)

  13. Μελέτη της επίδρασης της ατμοσφαιρικής ρύπανσης στην ανθρώπινη υγεία

    … determined with the use of Gas Chromatography coupled to Mass Spectrometry while the determination of metals/metalloids in the serum was performed inductively coupled plasma spectrometry. Subsequently, a method was developed for the determination of Aminopolycyclic Aromatic Hydrocarbons, …

    greece Repository record for Μελέτη της επίδρασης της ατμοσφαιρικής ρύπανσης στην ανθρώπινη υγεία (opens in a new tab)

  14. Phyllosilicate mineralogy, 40Ar/39Ar geochronology, and genesis of petrocalcic soils in the Southwest U.S.A.

    … evaluated using scanning electron microscopy, inductively-coupled plasma spectrometry, and x-ray diffraction analysis. No adverse effects were identified, however, intergrowths and/or inclusions of detrital mineral species persisted in the samples. Moreover, 40Ar/39Ar total gas ages exceeded …

    unlv Repository record for Phyllosilicate mineralogy, 40Ar/39Ar geochronology, and genesis of petrocalcic soils in the Southwest U.S.A. (opens in a new tab)

  15. Sourcing the clay: Iron Age pottery production around Poole Harbour and the Isle of Purbeck, Dorset, UK.

    … of 100 samples of pottery and clay, using inductively coupled plasma spectrometry, demonstrated the potters selected the iron-rich, red- firing clays, rather than the malleable white-firing clays. It also revealed that during the earlier Iron Age the potters utilised the Wealden Clay …

    bournemouth Repository record for Sourcing the clay: Iron Age pottery production around Poole Harbour and the Isle of Purbeck, Dorset, UK. (opens in a new tab)

Page 1 of 2