Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 1947 for “"Inductively coupled"”.

  1. Poly-phase inductively coupled power transfer systems

    This thesis proposes a new poly-phase track topology which provides high tolerance to lateral movement of inductive power transfer (IPT) pickups. IPT is a technology that is widely used for providing power to mobile loads in industrial situations or for monorails where the path of the load is well …

    auckland-ms Repository record for Poly-phase inductively coupled power transfer systems (opens in a new tab)

  2. Fluorescence Studies In The Inductively Coupled Plasma

    An Optima 3000 ICP-AES instrument was modified and the equipment necessary to carry out axial excitation atomic fluorescence was designed and constructed. Using this calibrated system, preliminary fluorescence experiments were not successful. As fluorescence is proportional to source intensity, it …

    plymouth Repository record for Fluorescence Studies In The Inductively Coupled Plasma (opens in a new tab)

  3. Simulation of Magnetically Confined Inductively Coupled Plasma

    … presented to address the need for high density inductively coupled plasmas with enhanced properties and a more uniform and consistent distribution, suitable for large-area material processing. Fluid model simulations of 3D argon inductively coupled plasma (ICP) were performed in COMSOL for the …

    sdstate Repository record for Simulation of Magnetically Confined Inductively Coupled Plasma (opens in a new tab)

  4. Inductively coupled, electrically small antenna for ionospheric heating

    … it's resonant design of a Small Loop Antenna coupled to a Capacitively Loaded Loop the antenna provides a high-Q, natural match to a 50~Ω source with no external matching networks required. With the ability to be tuned - by adjusting the capacitively loaded loop's capacitance - through the …

    ttu Repository record for Inductively coupled, electrically small antenna for ionospheric heating (opens in a new tab)

  5. Anomalous and nonlinear effects in inductively coupled plasmas

    … the nonlinear effects and heating are studied in inductively coupled plasma (ICP) in a regime of anomalous skin effect (nonlocal regime). In this regime the thermal motion of plasma electrons plays an important role, significantly influencing the processes associated with the penetration of …

    sask Repository record for Anomalous and nonlinear effects in inductively coupled plasmas (opens in a new tab)

  6. Inductively Coupled CMOS Power Receiver For Embedded Microsensors

    Inductively coupled power transfer can extend the lifetime of embedded microsensors that save costs, energy, and lives. To expand the microsensors' functionality, the transferred power needs to be maximized. Plus, the power receiver needs to handle wide coupling variations in real applications. …

    gatech Repository record for Inductively Coupled CMOS Power Receiver For Embedded Microsensors (opens in a new tab)

  7. Matrix effects in inductively coupled plasma mass spectrometry

    … strong polyatomic ion signals common in inductively coupled plasma mass spectrometry (ICP-MS) can be used as internal standards to correct for matrix interferences. Signals for most of the polyatomic ions, including metal oxides, are suppressed by a Cs matrix to the same extent as analyte …

    iastate Repository record for Matrix effects in inductively coupled plasma mass spectrometry (opens in a new tab)

  8. CMOS inductively coupled power receiver for wireless microsensors

    This research investigates how to draw energy from a distant emanating and alternating (i.e., AC) magnetic source and deliver it to a battery (i.e., DC). The objective is to develop, design, simulate, build, test, and evaluate a CMOS charger integrated circuit (IC) that wirelessly charges the …

    gatech Repository record for CMOS inductively coupled power receiver for wireless microsensors (opens in a new tab)

  9. Conventional inductively coupled plasma (ICP) and novel microwave inductively coupled atmospheric pressure plasma (MICAP) as ionization sources for trace elemental analysis

    … presents research on conventional argon (Ar) Inductively Coupled Plasma (ICP) and novel nitrogen (N2) Microwave Inductively Coupled Atmospheric Pressure Plasma (MICAP) as ionization source for elemental analysis, evaluating their analytical performance and applications when coupled with the …

    iastate Repository record for Conventional inductively coupled plasma (ICP) and novel microwave inductively coupled atmospheric pressure plasma (MICAP) as ionization sources for trace elemental analysis (opens in a new tab)

  10. Differentiation of paper types using element profiles generated using inductively coupled plasma-optical emission spectroscopy and inductively coupled plasma-mass spectrometry

    … the research in the elemental analysis of paper. Inductively coupled plasma- mass spectrometry (ICP-MS) has been used to generate element profiles for paper samples; however, this technique is expensive and not widely available for forensic laboratories.For this project, inductively coupled …

    msu Repository record for Differentiation of paper types using element profiles generated using inductively coupled plasma-optical emission spectroscopy and inductively coupled plasma-mass spectrometry (opens in a new tab)

  11. Passive inductively coupled wireless sensor for dielectric constant sensing

    In order to address the challenges of capacitive sensing in harsh environment, self resonant passive wireless sensors are studied. The capacitive sensing elements based on interdigitated capacitor (IDC) sensor are used. A semi-empirical model providing accurate capacitance calculation for IDCs over …

    texas Repository record for Passive inductively coupled wireless sensor for dielectric constant sensing (opens in a new tab)

  12. Smooth inductively coupled ring trap for cold atom optics

    … is the proof-of-principle experiment for an inductively coupled magnetic ring trap for applications in atom interferometry and quantum gas investigations. Atom interferometry utilises the wave nature of atoms for precision measurements of gravitational and inertial effects and to test …

    strathclyde Repository record for Smooth inductively coupled ring trap for cold atom optics (opens in a new tab)

  13. Inductively Coupled Plasma-Optical Emission Spectrometry For Forensic Analysis

    … fundamental characteristics and applications of inductively coupled plasma - optical emission spectrometry (ICP-OES) for forensic science purposes have been evaluated. Optimisation of ICP-OES for single elements using simplex techniques identified an ICP torch fitted with a wide bore injector …

    plymouth Repository record for Inductively Coupled Plasma-Optical Emission Spectrometry For Forensic Analysis (opens in a new tab)

  14. Solid sample introduction in inductively coupled plasma emission spectrometry.

    … made in the area of solid sample introduction in Inductively Coupled Plasma Emission Spectrometry (ICP-ES). As an alternative to solution nebulisation two methods of introducing samples to the ICP are investigated. The first of these uses the direct insertion probe technique first described by …

    sheffield-hallam Download PDF for Solid sample introduction in inductively coupled plasma emission spectrometry. (opens in a new tab)

  15. Transient Voltage and Current Amplitudes in Inductively Coupled Circuits

    … from one to the other they are said to be coupled. If the coupling is obtained by a circuit element (resistor, capacitor or coil) common to both circuits the coupling is direct. If the circuits are linked only by a magnetic field the coupling is called inductive. This paper will concern …

    sdstate Repository record for Transient Voltage and Current Amplitudes in Inductively Coupled Circuits (opens in a new tab)

Page 1 of 98