Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 18 of 18 for “"Inertia Estimation"”.

  1. Principal Moment of Inertia Estimation of Tethered Debris

    … from, knowledge of the principal mass moment of inertia (MMI) parameters of the debris. However, as debris is uncooperative and unresponsive, these parameters are often unknown to the Chaser. In this work, the principal moments of inertia of tethered debris are estimated by leveraging knowledge …

    buffalo Repository record for Principal Moment of Inertia Estimation of Tethered Debris (opens in a new tab)

  2. Distributed Machine Learning Approach to Fast Frequency Response-based Inertia Estimation in Low Inertia Grids

    … With the rapid growth of DERs towards a low inertia converter-dominated grid, the DERs can provide fast frequency response (FFR) services that can quickly counteract the change in system frequency through inertial support. However, in low voltage grids, frequency and voltage face dynamics …

    sdstate Repository record for Distributed Machine Learning Approach to Fast Frequency Response-based Inertia Estimation in Low Inertia Grids (opens in a new tab)

  3. Robust Online Inertia Estimation in Power Systems Using Ambient Data in the Presence of Inverter-Based Resources

    … reducing the system's effective rotational inertia and challenging frequency stability. Accurate online inertia estimation is essential for maintaining system reliability under these evolving conditions. This paper introduces a robust methodology for online inertia estimation using ambient …

    clemson Repository record for Robust Online Inertia Estimation in Power Systems Using Ambient Data in the Presence of Inverter-Based Resources (opens in a new tab)

  4. Enhancing Frequency Stability of Low-Inertia Grids with Novel Security Constrained Unit Commitment Approaches

    … generators are gradually being replaced by low-inertia inverter-based resources. Such transition introduces more complicated operation conditions. Insufficient system inertia is one of the challenges which would lead to dramatical change in rate of change of frequency (RoCoF) and further results …

    houston Repository record for Enhancing Frequency Stability of Low-Inertia Grids with Novel Security Constrained Unit Commitment Approaches (opens in a new tab)

  5. Addressing inertia and grid strength of operating high renewable grids

    … also pose challenges to grid strength and system inertia. The grid strength is weakened with IBRs connected, potentially leading to voltage stability and reliability issues, especially during large events such as Fault-Induced Delayed Voltage Response (FIDVR). Therefore, studies focus on FIDVR …

    utk-theses Repository record for Addressing inertia and grid strength of operating high renewable grids (opens in a new tab)

  6. System identification for development of distributed electric propulsion vertical take-off vehicles

    … presents a complete procedure for estimating the inertia matrix of a multi-rotor vertical take-off and landing vehicle. The procedure starts with an overview of vehicle dynamics. An estimator and a controller are introduced based on these dynamics, which can be tuned to the desired performance …

    uiuc Repository record for System identification for development of distributed electric propulsion vertical take-off vehicles (opens in a new tab)

  7. Data-Driven Situation Awareness for Power System Frequency Dynamics

    … of renewable energy increases, system inertia decreases, causing changes in system frequency dynamics. The power industry desires situation awareness of power system frequency dynamics to ensure secure and economic operation and control. Moreover, FNET/Grideye has abundant measured data …

    utk-theses Repository record for Data-Driven Situation Awareness for Power System Frequency Dynamics (opens in a new tab)

  8. Dynamic Inertia Monitoring and Optimization for Modern Grid Flexibility

    … a result, the network is losing its precious SG inertia used for instant frequency response after a contingency in the network. Low SG inertia in the network leads to rapid and significant frequency fluctuations becoming considerable challenges to address. As a result of low SG inertia in the …

    auckland-tech Repository record for Dynamic Inertia Monitoring and Optimization for Modern Grid Flexibility (opens in a new tab)

  9. Power System Frequency and Transient Stability Analysis and Control for High Renewable Power Grids

    … resources (IBRs), which lack inherent inertia and rely on hard-to-quantify virtual inertia contributions. This reduction in system inertia heightens the risks of frequency deviations and inter-area oscillations, necessitating real-time inertia estimation software and Wide Area …

    utk-theses Repository record for Power System Frequency and Transient Stability Analysis and Control for High Renewable Power Grids (opens in a new tab)

  10. Centimeter-Scale Spacecraft: Design, Fabrication, And Deployment

    … general spacecraft dynamics, control, and estimation problems with relevance to small and low-cost spacecraft are presented. These include control laws for flat-spin recovery and spin inversion, an algorithm for on-orbit inertia estimation, and variational integrators for spacecraft …

    cornell Repository record for Centimeter-Scale Spacecraft: Design, Fabrication, And Deployment (opens in a new tab)

  11. Participation of Battery Energy Storage Systems in Load Frequency Control of Power Systems

    … participation of BESS in frequency control, grid inertia enhancement can be performed through BESS for the inertial response of grid frequency that has been presented in the literature. However, this is contingent upon knowing the accurate knowledge of the equivalent grid inertia, which is …

    lsu-thes Repository record for Participation of Battery Energy Storage Systems in Load Frequency Control of Power Systems (opens in a new tab)

  12. Optimal black-start restoration of low-inertia networks enabled by innovative estimation and control methods for grid-forming converters

    … generators are decommissioned, the rotational inertia, electromechanical damping, fault current contribution, and inherent synchronising capability that have historically underpinned grid stability are systematically diminished. Grid-forming converters have emerged as the foremost enabling …

    strathclyde Repository record for Optimal black-start restoration of low-inertia networks enabled by innovative estimation and control methods for grid-forming converters (opens in a new tab)

  13. Impacts of High Renewable Power Grids on System Planning and Monitoring

    … brought by the integration of IBRs is the lower inertia in the power system. It is vital to monitor real-time inertia changes in the grid for situational awareness. In Chapter 7, a probing-based inertia estimation approach is proposed and validated in the Kauai island system under different …

    utk-theses Repository record for Impacts of High Renewable Power Grids on System Planning and Monitoring (opens in a new tab)

  14. A Novel Frequency Control and Flexible Dynamic Boundary Microgrids to Improve Grid Resiliency and Facilitate Renewable Generation Integration

    … PV power plants is presented based on real-time inertia estimation that minimizes the “spillage” of PV generation that has zero marginal costs. In the meantime, sufficient power reserves are maintained in the PV inverters that could respond to power system disturbances and prevent under frequency …

    utk-theses Repository record for A Novel Frequency Control and Flexible Dynamic Boundary Microgrids to Improve Grid Resiliency and Facilitate Renewable Generation Integration (opens in a new tab)

  15. Wide-Area Measurement-Based Applications for Power System Monitoring and Dynamic Modeling

    … preliminary data analytics studies including inertia estimation and analysis, fault-induced delayed voltage recovery (FIDVR) detection, and statistical analysis of oscillation database, are presented.</p>

    utk-theses Repository record for Wide-Area Measurement-Based Applications for Power System Monitoring and Dynamic Modeling (opens in a new tab)

  16. A virtual synchronous generator control in the power system with high penetration of renewable energies--weak grid!

    … system’s frequency control. This is because, inertia of the system declines with the continual displacement of the SG by the inertia-less RE generations such as solar photovoltaic (SPV) systems and wind turbine generation (WTG) systems. Therefore, on the occurrence of a small frequency …

    whiterose Download PDF for A virtual synchronous generator control in the power system with high penetration of renewable energies--weak grid! (opens in a new tab)

  17. ADAPTIVE CONTROL DESIGN FOR QUADROTORS

    … is considered with an adaptive component for the estimation of the uncertain mass of the quadrotor. For the rotational subsystem in the inner loop a backstepping based control design is adopted due to its systematic design and intuitive approach. An adaptive component is further integrated with it …

    siu-theses Repository record for ADAPTIVE CONTROL DESIGN FOR QUADROTORS (opens in a new tab)

  18. Power System Parameter Estimation for Enhanced Grid Stability Assessment in Systems with Renewable Energy Sources

    … to estimate three of these parameters: the Inertia, Topology, and Voltage Phasors. Without these parameters, it is no longer possible to determine the current stability of the grid. Through the use of machine learning, empirical studies, and mathematical optimization it is possible to …

    vt Repository record for Power System Parameter Estimation for Enhanced Grid Stability Assessment in Systems with Renewable Energy Sources (opens in a new tab)