Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 13 of 13 for “"Inertia constant"”.

  1. Transverse vibrations of a beam with varying moment of inertia, constant axial force and simple or elastic end conditions

    … elastic boundary conditions, varying moments of inertia and axial forces. Comparison of results was made to analytical frequency solutions. One result was verified experimentally.

    ttu Repository record for Transverse vibrations of a beam with varying moment of inertia, constant axial force and simple or elastic end conditions (opens in a new tab)

  2. Frequency and Damping Characteristics of Generators in Power Systems

    … of generators are highly dependent on the system inertia constant. Therefore, the higher inertia constant is a critical factor to ensure the system is more stable.

    vt Repository record for Frequency and Damping Characteristics of Generators in Power Systems (opens in a new tab)

  3. Use battery energy storage system to improve Inertial constant in single and multi-machines

    … for bringing various improvements in terms of inertia and damping have been investigated in this research. As it is known that renewable energy sources are a vital part of electricity production. When the different renewable resources such as wind, sun or biogas are used together, with the …

    adelaide Repository record for Use battery energy storage system to improve Inertial constant in single and multi-machines (opens in a new tab)

  4. High Frequency AC Power Systems

    … depends on physical factors such as the inertias of rotating machines, the impedances of power buswork, and the operating speeds of circuit protection devices. In this research, we first explored the benefits of higher-frequency systems, including how weight and volume of equipment such …

    south-carolina Repository record for High Frequency AC Power Systems (opens in a new tab)

  5. Emulation of An Aeroderivative Twin-Shaft Gas Turbine Engine Using An AC Electric Motor Drive

    … drive, based on torque, power, and inertia. This method accounts for the difference in inertia between the engine and the emulating motor; it establishes for the first time the nominal and peak torque requirements of the machine and the peak power and current requirements of the …

    south-carolina Repository record for Emulation of An Aeroderivative Twin-Shaft Gas Turbine Engine Using An AC Electric Motor Drive (opens in a new tab)

  6. Distributed Machine Learning Approach to Fast Frequency Response-based Inertia Estimation in Low Inertia Grids

    … With the rapid growth of DERs towards a low inertia converter-dominated grid, the DERs can provide fast frequency response (FFR) services that can quickly counteract the change in system frequency through inertial support. However, in low voltage grids, frequency and voltage face dynamics …

    sdstate Repository record for Distributed Machine Learning Approach to Fast Frequency Response-based Inertia Estimation in Low Inertia Grids (opens in a new tab)

  7. Method of Modeling the Swing Equation Using Time Synchronized Measurements

    … electrical power systems, frequency changes constantly based on system dynamics. Modeling network dynamics from oscillations and transients using time-synchronized measurements can provide real-time information, including angular displacements, voltage and current phasors, frequency changes, …

    portland-state Repository record for Method of Modeling the Swing Equation Using Time Synchronized Measurements (opens in a new tab)

  8. Fault Ride-through of Wind Parks with Induction Generators

    … influences of different parameters such as rotor inertia constant, short circuit ratio, and pre-fault operating point on the FRT have been investigated. Two aggregation methods for large wind farms have been studied and an error estimation has been made. It is shown that a two-machine model is the …

    chalmers Repository record for Fault Ride-through of Wind Parks with Induction Generators (opens in a new tab)

  9. Advanced Inverter control for mixed source microgrids

    … with different types of loads. A virtual inertia design method for the VOC inverter with a mixed source microgrid is presented to improve the frequency stability issues of the system. The per unit inertia constant of a VOC inverter is derived when coupled with a synchronous generator in an …

    unsw Repository record for Advanced Inverter control for mixed source microgrids (opens in a new tab)

  10. Phasor Measurement Unit Data-Based Steady State and Dynamic Model Estimation

    … transfer function. Generator parameters such as inertia constant, damping coefficients, and regulation speed constant can be estimated.

    usf Repository record for Phasor Measurement Unit Data-Based Steady State and Dynamic Model Estimation (opens in a new tab)

  11. Optimal black-start restoration of low-inertia networks enabled by innovative estimation and control methods for grid-forming converters

    … generators are decommissioned, the rotational inertia, electromechanical damping, fault current contribution, and inherent synchronising capability that have historically underpinned grid stability are systematically diminished. Grid-forming converters have emerged as the foremost enabling …

    strathclyde Repository record for Optimal black-start restoration of low-inertia networks enabled by innovative estimation and control methods for grid-forming converters (opens in a new tab)

  12. Dynamic Modeling of Commercial-Off-The-Shelf Smart Inverters Using Power-Hardware-In-The-Loop

    … Additionally, inverter-based systems have low inertia and are more vulnerable to significant rate-of-change-of-frequency (ROCOF) and frequency deviations. The growing use of renewable energy sources also leads to uncertainties in time-varying system parameters such as inertia and damping …

    sdstate Repository record for Dynamic Modeling of Commercial-Off-The-Shelf Smart Inverters Using Power-Hardware-In-The-Loop (opens in a new tab)

  13. Dynamic Inertia Monitoring and Optimization for Modern Grid Flexibility

    … a result, the network is losing its precious SG inertia used for instant frequency response after a contingency in the network. Low SG inertia in the network leads to rapid and significant frequency fluctuations becoming considerable challenges to address. As a result of low SG inertia in the …

    auckland-tech Repository record for Dynamic Inertia Monitoring and Optimization for Modern Grid Flexibility (opens in a new tab)