Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 25 for “"Inherent Damping"”.

  1. Role of thyristor controlled series compensators in damping sub-synchronous resonance in power systems

    … (TCSC) applications use Sub-Synchronous Damping Controllers (SSDCs) to avoid SSR. The TCSC inherently provides some level of damping in the sub synchronous frequency range even without SSDCs. However, the mechanism behind the inherent damping capability of the TCSC and its application of …

    manitoba Repository record for Role of thyristor controlled series compensators in damping sub-synchronous resonance in power systems (opens in a new tab)

  2. Fork Configuration Damper (FCDs) for Enhanced Dynamic Performance of High-rise Buildings

    … of high-rise buildings is highly dependent on damping. Full-scale measurements of high-rise buildings have shown that the inherent damping decreases with height and recent in-situ measurements have shown that the majority of buildings over 250 meters have levels of damping less than 1% of …

    toronto-retro Repository record for Fork Configuration Damper (FCDs) for Enhanced Dynamic Performance of High-rise Buildings (opens in a new tab)

  3. Field Monitoring and Numerical Investigation of Constrained Layer Damper for Mitigation of Wind-induced Vibration of High Mast Illumination Poles

    … (HMIP) are tall and slender structures with low inherent damping. The Kansas Department of Transportation (KDOT) discovered premature cracking near the handhole of several HMIPs in Western Kansas. In addition, multiple video recordings captured significant HMIP vibrations under high wind. This …

    ku Repository record for Field Monitoring and Numerical Investigation of Constrained Layer Damper for Mitigation of Wind-induced Vibration of High Mast Illumination Poles (opens in a new tab)

  4. Theoretical and experimental study into the dynamics and control of a flexible beam with a DC-servo motor actuator

    … Accurate modeling of the system’s inherent damping characteristics is achieved by analyzing experimental data. Gains were iterated yielding minimum-gain norm and minimum-sensitivity norm solutions to meet imposed eigenvalue placement constraints. Results for the two solutions and …

    vt Repository record for Theoretical and experimental study into the dynamics and control of a flexible beam with a DC-servo motor actuator (opens in a new tab)

  5. Nature Inspired meta-damped elastic plates

    … geometry, material distribution and internal damping characteristics while maintaining high stiffness. The architecture is engineered such that it manipulates the dynamic response of the system by redistributing vibrational energy and dissipating it across multiple scales. This behavior is …

    washington Repository record for Nature Inspired meta-damped elastic plates (opens in a new tab)

  6. Granular sloshing absorbers for vibration control

    … Liquid Dampers. These devices provide optimal damping at the natural frequency of the structure. This thesis proposes a novel passive damping device, that uses a granular material sloshing in a rotating cylindrical container as the energy sink. Tuning of a granular sloshing absorber is shown to …

    vu-aus Download PDF for Granular sloshing absorbers for vibration control (opens in a new tab)

  7. Influence of Construction Details on the Vibration Performance of Cold-Formed Steel Floor Systems

    … floor systems are usually lighter and have less inherent damping. If designers are going to use the current span deflection criteria when designing residential floor systems, it is imperative to find the construction and design details that will limit these annoying vibrations in cold-formed …

    waterloo Repository record for Influence of Construction Details on the Vibration Performance of Cold-Formed Steel Floor Systems (opens in a new tab)

  8. Nonlinear Analysis of a Tapered Impact Damper Using the Method of Harmonic Balance

    … cycles can be produced when structures with low inherent damping, including traffic signal structures, are excited near one of their natural frequencies. Measures implemented for the attenuation of these vibration amplitudes must be considered to prevent failure due to fatigue cracking. For the …

    tamu Repository record for Nonlinear Analysis of a Tapered Impact Damper Using the Method of Harmonic Balance (opens in a new tab)

  9. Low-Velocity Impact, Vibration and Shock Response of Unstitched/Stitched E- And S- Glass/Vinyl Ester Composites

    … investigated. The stiffness and loss factor (inherent damping) properties are obtained from impulse-frequency response experiments using the hammer excitation method. Drop weight impact testing machine was used to carry out low-velocity punch shear tests on the composite specimens following …

    mississippi Repository record for Low-Velocity Impact, Vibration and Shock Response of Unstitched/Stitched E- And S- Glass/Vinyl Ester Composites (opens in a new tab)

  10. Passive Apaptive Damping for High Stiffness-low Mass Materials Incorporating Negative Stiffness Elements

    … weight in transportation, but show little inherent damping. A new composite material that exhibits high stiffness and high damping might reduce issues with vibration in mechanical systems and structures. The material comprises three constituents: negative springs, positive springs, and …

    tamu Repository record for Passive Apaptive Damping for High Stiffness-low Mass Materials Incorporating Negative Stiffness Elements (opens in a new tab)

  11. Viscoelastic Coupling Dampers (VCDs) for Outrigger Systems in Tall Building Structures

    … over the past few decades to increase the inherent damping of tall building structures. The VCD system consists of viscoelastic (VE) panels bolted to steel ductile structural sections anchored to reinforced concrete walls and columns. VE panels are comprised of high damping viscoelastic …

    toronto-retro Repository record for Viscoelastic Coupling Dampers (VCDs) for Outrigger Systems in Tall Building Structures (opens in a new tab)

  12. Numerical Modelling of Tuned Liquid Dampers Using Implicit Smoothed Particle Hydrodynamics

    … frequency of the building. Typically, the inherent damping of the TLD is improved by adding additional damping devices, such as screens. Studying the nonlinear flow of TLDs is imperative for designers in order to understand their response, and numerical modelling is essential for their …

    mcmaster Repository record for Numerical Modelling of Tuned Liquid Dampers Using Implicit Smoothed Particle Hydrodynamics (opens in a new tab)

  13. Nondestructive Level III Damage Evaluation and System Identification in Structures Based on the Rate of the Total Energy

    … in the element-wise mass, stiffness, and damping characteristics of a structure, utilizing dynamic response data of the system. The effect of the proportional and non-proportional types of the inherent damping of the structure in the form of viscous resistance to strain of the material and …

    tamu Repository record for Nondestructive Level III Damage Evaluation and System Identification in Structures Based on the Rate of the Total Energy (opens in a new tab)

  14. Hybrid Active/Passive Models with Frequency Dependent Damping

    To add damping to structures, viscoelastic materials (VEM) are added to structures. In order to enhance the damping effect of the VEM, a constraining layer is attached, creating a passive constrained layer damping treatment (PCLD). When this constraining layer is an active element, the treatment is …

    vt Repository record for Hybrid Active/Passive Models with Frequency Dependent Damping (opens in a new tab)

  15. Investigations on Void Formation in Composite Molding Processes and Structural Damping in Fiber-Reinforced Composites with Nanoscale Reinforcements

    … vibrational loads during service, and improved damping characteristics of the composite structure are desirable. To this end, a second goal is to explore the use of matrix-embedded nanoscale reinforcements to augment the inherent damping capabilities in FRCs. The first objective is addressed …

    vt Repository record for Investigations on Void Formation in Composite Molding Processes and Structural Damping in Fiber-Reinforced Composites with Nanoscale Reinforcements (opens in a new tab)

  16. Seismic Performance Assessment of Wood-Frame Shear Wall Structures

    … in this study include level of critical damping, analytical modeling of damping, hysteresis model shape variations, ground motion characteristics, level of gravity loads, and floor acceleration variations. A subset of building model designs that were originally designed for the …

    vt Repository record for Seismic Performance Assessment of Wood-Frame Shear Wall Structures (opens in a new tab)

  17. Investigating Ferroelastic and Piezoelectric Vibration Damping Behavior in Nickel-Barium Titanate and Nickel-PZT Composites

    … are new materials being explored for vibration damping purposes. The high damping ability of ferroelectric and piezoelectric ceramics such as barium titanate (BaTiO3) and lead zirconate titanate (PZT) is due to the anelastic response of ferroelastic domain walls to applied external stress. In …

    vt Repository record for Investigating Ferroelastic and Piezoelectric Vibration Damping Behavior in Nickel-Barium Titanate and Nickel-PZT Composites (opens in a new tab)

  18. Design and Application of an Elastomeric Series Elastic Actuator for Rehabilitation Robotics

    … build on this concept by using materials with inherent damping, which can further improve pHRI, increase force-volume ratios and improve safety. The first contribution of the thesis is the derivation of a model that allows the eSEA to measure pHRI torque. It is validated over the course of 8-9 …

    auckland-ms Repository record for Design and Application of an Elastomeric Series Elastic Actuator for Rehabilitation Robotics (opens in a new tab)

  19. Fluid Inerter Based Vibration Suppression: Modelling Methodology

    … absorbers with a combination of stiffness, damping and inertance have been shown to be effective through numerous theoretical studies.<br/>A case study is carries out to investigate the potential reduction in road damage by incor- porating the inerter element into truck suspension systems. …

    bristol Repository record for Fluid Inerter Based Vibration Suppression: Modelling Methodology (opens in a new tab) Download PDF for Fluid Inerter Based Vibration Suppression: Modelling Methodology (opens in a new tab)

  20. Optimum Inerter-based Absorbers for Cable Vibration Suppression

    … large amplitude vibrations due to their low inherent damping. Compared with conventional viscous dampers, inerter-based vibration absorbers can potentially be more effective to improve damping performance. The inerter is a two-port mechanical element with the property that the applied force …

    bristol Repository record for Optimum Inerter-based Absorbers for Cable Vibration Suppression (opens in a new tab) Download PDF for Optimum Inerter-based Absorbers for Cable Vibration Suppression (opens in a new tab)

Page 1 of 2