Showing 1 to 16 of 16 for “"Inline Coherent Imaging"”.

  1. Inline Coherent Imaging

    … welding, drilling, cutting and ablation called inline coherent imaging (ICI). The approach borrows the coherent imaging ideas from the primarily medical field of optical coherence tomography and adapts them to the new application. Without requirements for flawless image quality and limitations …

    queens Repository record for Inline Coherent Imaging (opens in a new tab)

  2. Stroboscopic Inline Coherent Imaging

    Inline coherent imaging (ICI) is an in-situ monitoring technique, used in laser processing applications such as welding and additive manufacturing. Conventional ICI systems image with a continuous-wave broadband light source, which makes the system susceptible to an effect known as motion artifact. …

    queens Repository record for Stroboscopic Inline Coherent Imaging (opens in a new tab)

  3. Inline Coherent Imaging of Laser Keyhole Welding

    … to model, understand, and control this process. Inline coherent imaging (ICI), a laser-based ranging technique, has previously been demonstrated as an effective tool for in-situ measurement of the keyhole depth. In this work, I seek to improve our understanding of ICI's measurement of the …

    queens Repository record for Inline Coherent Imaging of Laser Keyhole Welding (opens in a new tab)

  4. Inline Coherent Imaging Applied to Laser Micromachining

    … achieve automation of laser micromachining, a coherent imaging technique adapted from spectral domain optical coherence tomography (SD-OCT) is applied “inline”with a machining laser to monitor the depth changing information. The axial resolution of the inline coherent imaging (ICI) system is …

    queens Repository record for Inline Coherent Imaging Applied to Laser Micromachining (opens in a new tab)

  5. Inline Coherent Imaging of Laser Additive Manufacturing

    … In this thesis a low-coherence interferometric imaging technique, termed inline coherent imaging (ICI), is integrated into the selective laser melting process to monitor melt pool morphology changes and stability at 200 kHz with axial and transverse resolutions reaching 6 µm and 35 µm …

    queens Repository record for Inline Coherent Imaging of Laser Additive Manufacturing (opens in a new tab)

  6. Monitoring Material Modification using Inline Coherent Imaging

    … in situ metrology is required. In this work, a coherent imaging technique analogous to spectral domain optical coherence tomography (SD-OCT) was applied inline with a machining laser in order to monitor the cut development of various materials for industrial and biomedical applications. Such …

    queens Repository record for Monitoring Material Modification using Inline Coherent Imaging (opens in a new tab)

  7. Controlled fiber laser bone ablation using inline coherent imaging

    … brain surgery). In this work, a low-coherence imaging technique known as inline coherent imaging (ICI) is utilized to monitor bone ablation processes and provide depth information about the sample with on-the-fly signal processing. ICI is analogous to spectral domain optical coherence …

    queens Repository record for Controlled fiber laser bone ablation using inline coherent imaging (opens in a new tab)

  8. Process Monitoring and Defect Detection of Additive Manufacturing Using Inline Coherent Imaging

    … quality assurance techniques. In this thesis, inline coherent imaging (ICI), a broadband, spatially coherent imaging technique, is used to observe the SLM process in 15 - 45 $\mu m$ 316L stainless steel. Imaging of both single and multilayer builds is performed at a rate of 200 $kHz$, with a …

    queens Repository record for Process Monitoring and Defect Detection of Additive Manufacturing Using Inline Coherent Imaging (opens in a new tab)

  9. Monitoring Laser Material Processing by Simultaneous Inline Coherent Imaging and Integrating Sphere Radiometry

    … combine integrating sphere radiometry (ISR) and inline coherent imaging (ICI) to simultaneously measure time-resolved absorptance and vapour depression depth during stationary, high-irradiance laser illumination of a metal (AISI 316 stainless steel). This allows, for the first time, the …

    queens Repository record for Monitoring Laser Material Processing by Simultaneous Inline Coherent Imaging and Integrating Sphere Radiometry (opens in a new tab)

  10. Inline Coherent Imaging Based Control of Laser Machining Processes using a Field-Programmable Gate Array

    … physical dimensions. A recent invention, inline coherent imaging (ICI), uses the interference properties of light to monitor the depth of the processing beam at high speeds. However, the computational demands of ICI data processing are intensive, and it is difficult for standard computers …

    queens Repository record for Inline Coherent Imaging Based Control of Laser Machining Processes using a Field-Programmable Gate Array (opens in a new tab)

  11. Shedding Light on Laser-Metal Interactions: In situ Monitoring with Inline Coherent Imaging and Integrating Sphere Radiometry

    … interactions in inert environments. By employing inline coherent imaging (ICI) and integrating sphere radiometry (ISR) at high imaging rates (200 kHz), the measurements reveal the time-dependent cavity-enhanced absorptance within these keyholes. The results show that processing in an argon-rich …

    queens Repository record for Shedding Light on Laser-Metal Interactions: In situ Monitoring with Inline Coherent Imaging and Integrating Sphere Radiometry (opens in a new tab)

  12. Inline Temperature Imaging: A Non-contact Temperature Measurement Technique for Laser Processing

    … and high-resolution to capture these dynamics. Inline coherent imaging (ICI) is a low coherence interferometric ranging technique that has previously been used to characterise the morphology of both processes. In this work, I developed a novel method to collect high-resolution, high-speed …

    queens Repository record for Inline Temperature Imaging: A Non-contact Temperature Measurement Technique for Laser Processing (opens in a new tab)

  13. Ablation of Steel by Microsecond Pulse Trains

    … morphology changes to melt and vapour ejection. Inline coherent imaging (ICI), a broadband, spatially-coherent imaging technique, is used to monitor the ablation process. The pulse parameter space is explored and the key regimes are determined. Material removal is observed when the pulse delay is …

    queens Repository record for Ablation of Steel by Microsecond Pulse Trains (opens in a new tab)

  14. Self-witnessing Coherent Imaging for Automatic Noise Filtering and Artifact Removal in Laser Process Monitoring

    … we need in-line monitoring during the process. Inline Coherent Imaging (ICI) is a process monitoring technique that has been demonstrated to measure keyhole depth (down to 15 µm axial resolution) at high camera rates ( 200 kHz), with unparalleled sensitivity and dynamic range. Unfortunately, it …

    queens Repository record for Self-witnessing Coherent Imaging for Automatic Noise Filtering and Artifact Removal in Laser Process Monitoring (opens in a new tab)

  15. In situ and operando Monitoring of Laser Additive Manufacturing

    … an interferometric monitoring technique called inline coherent imaging (ICI) is applied to LAM for high-speed (200 kHz) in situ morphology measurements and defect detection. The Fraser group powder bed fusion (PBF) machine was used to demonstrate manual layer-wise control of a 3D build of 316L …

    queens Repository record for In situ and operando Monitoring of Laser Additive Manufacturing (opens in a new tab)

  16. Highly Efficient Thermal Ablation of Silicon and Ablation in Other Materials

    … cost. The work here shows that by combining an imaging technique frequently used in ophthalmology called optical coherence tomography (OCT) with a machining platform, in situ observation of ablation can be made. This combination, known as in-line coherent imaging (ICI), allows information to be …

    queens Repository record for Highly Efficient Thermal Ablation of Silicon and Ablation in Other Materials (opens in a new tab)