Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 150 for “"Input resistance"”

  1. Kamieninių ląstelių elektrofiziologinių savybių tyrimas /

    … expression, cell resting membrane potential and input resistance. The method of whole-cell patch –clamp recordings from stem cells was used. We found that inward L-type Calcium currents are not present in the control stem cells. Electrical stimulation of stem cells does not result in L-type …

    vilnius Repository record for Kamieninių ląstelių elektrofiziologinių savybių tyrimas / (opens in a new tab)

  2. Synaptic and cellular changes lead to aberrant hippocampal function in the DLG2+/- (PSD93+/-) rat

    … reduced dendritic arborisation but had reduced input resistance. Computational modelling confirmed the incongruence between reduced dendric arborisation and reduced input resistance, suggesting that potassium conductance was increased in DLG2+/- hets. Further computational modelling showed that …

    bristol Repository record for Synaptic and cellular changes lead to aberrant hippocampal function in the DLG2+/- (PSD93+/-) rat (opens in a new tab)

  3. Actions of neuropeptides on mouse spinal neurones in culture

    … depolarizations accompanied by an increased input resistance were apparently voltage dependent. These responses were abolished at potentials more negative than -90mV and did not invert under normal recording conditions. 9] The enkephalin-evoked depolarizations associated with a decreased …

    st-andrews Repository record for Actions of neuropeptides on mouse spinal neurones in culture (opens in a new tab)

  4. Efficiency characterization of small antennas

    … validity of Wheeler's assumption that the loss resistance of the antenna placed in the Wheeler's cap is not changed by the presence of the cap if the dimension of the cap is appropriately large. This proof extends the validation of Wheeler's assumption to a hollow cavity of arbitrary shape. It …

    nebraska Repository record for Efficiency characterization of small antennas (opens in a new tab)

  5. Subtype specific dysfunction of inhibitory interneurons in Fragile-X syndrome

    … action potentials across a range of current inputs and had lower input resistance compared to cells with weak SFA. Strong SFA cells also had higher sag and rebound in response to hyperpolarizing current injections. Voltage-clamp recordings showed that the hyperpolarization activated current I …

    texas Repository record for Subtype specific dysfunction of inhibitory interneurons in Fragile-X syndrome (opens in a new tab)

  6. On the accuracy of estimating input impedance of probe-fed air-substrate microstrip patch antennas using the theory of characteristic modes

    … modes are developed to estimate the input impedance of air-substrate, coaxial probe-fed, microstrip patch antennas with arbitrarily shaped patches. Such an antenna with an L-shaped patch is fabricated and experimentally measured, and a case study performed comparing the accuracy of …

    uiuc Repository record for On the accuracy of estimating input impedance of probe-fed air-substrate microstrip patch antennas using the theory of characteristic modes (opens in a new tab)

  7. Microstrip antennae with various substrate thickness / by Mehmet Kara.

    … calculating the patch dimensions, the resonant input resistance, the resonant frequency, the bandwidth and the radiation patterns of elements, as well as the mutual coupling coefficients of arrays.

    adelaide Repository record for Microstrip antennae with various substrate thickness / by Mehmet Kara. (opens in a new tab)

  8. Study of Reconfigurable Small Loop Antennas Mounted on Cylindrical Platform

    … by poor radiation efficiency and small input resistance. When the geometry of the loop varies, the performance of the loop can be changed. The platform on which the loop is mounted also has significant effect on the performance of the loop. In this thesis, different types of loops with …

    marquette Repository record for Study of Reconfigurable Small Loop Antennas Mounted on Cylindrical Platform (opens in a new tab)

  9. The role of Cav3.2 Ca2+ channels in influencing the activity of the layer II stellate cells of the Medial Entorhinal Cortex

    … ventral neurons displayed significantly reduced input resistance but little difference in resting membrane potential (RMP) compared with CaV3.2+/+ ventral neurons. Consequently, depolarizing steps resulted in fewer action potentials in CaV3.2-/- ventral SC than in wild type neurons. In contrast, …

    ucl Repository record for The role of Cav3.2 Ca2+ channels in influencing the activity of the layer II stellate cells of the Medial Entorhinal Cortex (opens in a new tab)

  10. The morphology and electrophysiology of leech neurones in vitro: A study using microfabricated devices

    … in vivo and (b) isolation causes an increase in input resistance. 4. The results of an experiment designed to show a correlation between input resistance and the length of processes, suggest that the removal of processes during extraction is not the main cause of the high input resistance of …

    glasgow Repository record for The morphology and electrophysiology of leech neurones in vitro: A study using microfabricated devices (opens in a new tab)

  11. Elucidating the reversibility of ataxia

    … with posterior KO PCs appearing to have elevated input resistance. Two-week expression of C-trm b-III spectrin in 3-month old KO animals significantly reduced Purkinje cell input resistance when compared to non-transduced cells (p=0.0139, N=4-5, n=15), but no effect was seen 9 months after viral …

    edinburgh Repository record for Elucidating the reversibility of ataxia (opens in a new tab)

  12. Effects of Abstraction and Assumptions on Modeling Motoneuron Pool Output

    … evidence has shown that a-MNs of lower input resistance innervating muscles of the cat hind limb receive greater synaptic current from volitional input than do those of higher input resistance. To test the significance of this finding, a control scheme was adopted in which input to cells …

    ohiolink Repository record for Effects of Abstraction and Assumptions on Modeling Motoneuron Pool Output (opens in a new tab)

  13. Biophysics underlying bistable neurons with branching dendrites

    … to better understand the physiological input-output properties of motor neurons in vivo: input resistance, system time constant, and three signal propagation properties between the soma and dendrites that depend on the signal direction (i.e. soma to dendrites or vice versa) and type …

    alberta Repository record for Biophysics underlying bistable neurons with branching dendrites (opens in a new tab)

  14. Sensory and associative microcircuits in the olfactory cortex

    … excitatory cells in the aPC receive sensory inputs from the olfactory bulb and intracortical associative inputs from the PC itself and from other cortical region. We characterize organization principles of excitatory sensory and local intracortical associative microcircuits in acute slices of …

    fu-berlin Repository record for Sensory and associative microcircuits in the olfactory cortex (opens in a new tab)

  15. Electrophysiological properties of spinal dorsal horn neurons in vitro: calcium-dependent action potentials and actions of neuroactive peptides

    … was always associated with a fall in neuronal input resistance, in the case of somatostatin the similar effect was less consistently observed. These responses were brought about by both pre- and postsynaptic actions of the peptides;Bath application of substance P depolarized dorsal horn neurons …

    iastate Repository record for Electrophysiological properties of spinal dorsal horn neurons in vitro: calcium-dependent action potentials and actions of neuroactive peptides (opens in a new tab)

  16. Application of Cohn's sensitivity theorem to time domain responses

    … the ratio of a fractional change in the d,c, input resistance to a fractional change in an internal resistance is equal to the square of the ratio of the current through that internal resistance to the d.c. input current. The theorem is extended to show the sensitivity of input impedance to …

    nps Repository record for Application of Cohn's sensitivity theorem to time domain responses (opens in a new tab)

  17. Modeling and Attenuation of Motion Artifacts in Capacitive ECG

    … and it can even saturate the analog front-end's input. MAs are often described as random or unpredictable events, however, in this dissertation they were modeled based on triboelectric nanogenerator theory. The proposed model uses information on displacement and speed to mimic the MA behavior. It …

    concordia

  18. Analog implementation of a current-mode Rectified Linear Unit (ReLU) for artificial neural networks

    … is proposed. The design employs current-mode inputs that are combined and applied to a tightly coupled active feedback loop that presents a low input resistance. The design also provides for simultaneous derivative evaluation. The basic operation is verified within a neural network …

    texas Repository record for Analog implementation of a current-mode Rectified Linear Unit (ReLU) for artificial neural networks (opens in a new tab)

  19. Dopaminergic modulation of entorhinal cortex function

    … entorhinal cortex and may modulate olfactory inputs that also terminate in this area. In awake rats, increasing extracellular dopamine levels in the entorhinal cortex with a selective dopamine reuptake inhibitor facilitated basal synaptic transmission in piriform cortex inputs to layer II. …

    concordia

Page 1 of 8