Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 73 for “"Inrush Current"”

  1. Magnetic saturation and inrush current in transformers

    … find a new method, used to discriminate between inrush current and short circuit current based on the waveform discrimination using neural network which is different from the conventional method using the ratio of second harmonic current to differential current.

    nanyang Repository record for Magnetic saturation and inrush current in transformers (opens in a new tab)

  2. An inrush current model for core type transformers

    … approach has been developed for simulating inrush current for core type transformers. The model is capable of computing inrush current for various phase connection schemes under different initial conditions. A three phase thyristor controlled switch has been designed and constructed to be …

    manitoba Repository record for An inrush current model for core type transformers (opens in a new tab)

  3. Operation of HVDC converters for transformer inrush current reduction

    The present PhD thesis deals with transformer inrush current in offshore grids including offshore wind farms and High Voltage Direct Current (HVDC) transmission systems. The inrush phenomenon during transformers energization or recovery after the fault clearance is one of important concerns in …

    barcelona Repository record for Operation of HVDC converters for transformer inrush current reduction (opens in a new tab)

  4. Point-on-wave switching for distribution transformer inrush current reduction

    Les transitoires d’afflux peuvent avoir des effets hautement indésirables sur les transformateurs de distribution et sont dues à l'asymétrie du flux noyau pendant l'excitation. Ces courants d'afflux peuvent être de très grande ampleur, peut être riche en harmonique, peut nuire le transformateur …

    mcgill Repository record for Point-on-wave switching for distribution transformer inrush current reduction (opens in a new tab)

  5. PERFORMANCE OF DIGITAL DISTANCE RELAY ALGORITHMS FOR PROTECTING TRANSFORMER TERMINATED LINES

    … d.c. which is normally present in transient currents are among some of the characteristics of the algorithms that can be examined. Their performance can also be examined using fault data or data of transients like inrush currents which occur during switching-on of transformers. This thesis is …

    sask Repository record for PERFORMANCE OF DIGITAL DISTANCE RELAY ALGORITHMS FOR PROTECTING TRANSFORMER TERMINATED LINES (opens in a new tab)

  6. Comparison of control strategies for squirrel-cage induction generator-based wind energy conversion systems

    … responses, since they do not have internal current controllers. However, stator-flux slip control presents high inrush-current and a poor dynamic response and direct torque control presents high torque ripples and poor performance at low speeds. On the other hand, rotor-flux slip control, …

    brazil-ufrn Repository record for Comparison of control strategies for squirrel-cage induction generator-based wind energy conversion systems (opens in a new tab)

  7. Performance Optimization of the Differential Protection Schemes

    Current differential protection principle is superior in terms of sensitivity and speed of operation in comparison with other protection principle used in power systems. From the last five decades, various current differential protection schemes are widely used to protect busbars, transformers, and …

    uno Repository record for Performance Optimization of the Differential Protection Schemes (opens in a new tab)

  8. Motor starting with shunt capacitors: An alternate approach to voltage dip control

    … to cause undesirable voltage dip because of high inrush current during starting, especially when fed from weak AC systems. For this reason, large motors are often started with reduced voltage. This thesis proposes full-voltage motor starting with shunt capacitors. Two types of capacitors are used: …

    unlv Repository record for Motor starting with shunt capacitors: An alternate approach to voltage dip control (opens in a new tab)

  9. Methods to reduce the starting current of an induction motor.

    Power system loads that have high starting currents are a serious source of concern in smaller grids or remote locations on the main grid. This problem is envisaged to be exacerbated by the rollout of smart microgrids. When a high power induction motor is turned on in such a power system, its …

    ukzn Repository record for Methods to reduce the starting current of an induction motor. (opens in a new tab)

  10. Realization of a High Power Microgrid Based on Voltage Source Converters

    … value changes by a factor of three from low current to peak current. The variable inductor approach gives many benefits with regard to high power microgrid applications. The design process of the inductor is described and simulation tools are used to verify the feasibility before final …

    arkansas Repository record for Realization of a High Power Microgrid Based on Voltage Source Converters (opens in a new tab)

  11. An ATP/EMTP model for the study of both normal and abnormal substation equipment operation

    … AT AUTHOR'S REQUEST.] In electric utility, overcurrent and overvoltage transients in switching operations often cause severe damage on the power system equipments. In this study, Alternative Transients Program -Electromagnetic Transients Program (ATP-EMTP) was employed for a general utility …

    missouri Repository record for An ATP/EMTP model for the study of both normal and abnormal substation equipment operation (opens in a new tab)

  12. Modeling and characterization of single-phase and three-phase transformers based on minimum information

    … from the information obtained from the inrush current. The energizing process of a transformer results in the generation of a high inrush current due to the saturation of the transformer core. This current can cause several problems, such as protections tripping and consequently being …

    barcelona Repository record for Modeling and characterization of single-phase and three-phase transformers based on minimum information (opens in a new tab)

  13. Transformer modelling for transient studies

    … by the manufacturer. For ferroresonance and inrush current studies, core saturation needs to be represented reasonably well. A direct approach to producing nonlinear peak flux-current and voltage-current characteristic of the iron core, taking iron losses into account, is presented. The …

    ubc Repository record for Transformer modelling for transient studies (opens in a new tab)

  14. Development of mathematical morphology systems for signal feature extraction and detection

    … (ECG) signal analysis and power transformer inrush current identification. MM methodologies are founded on set-theoretic concepts and nonlinear superpositions of signals and images. Morphological operations have been applied successfully to a wide range of problems including image processing …

    liverpool Repository record for Development of mathematical morphology systems for signal feature extraction and detection (opens in a new tab)

  15. Power Electronic-Based Solutions for Transient-Free Energization of Traction Power Transformers

    … is energized, a high-magnitude asymmetrical current, known as in- rush current, can flow into the energized winding while the other winding is open-circuited. This can lead to the malfunction of differential protective relays and generate axial and radial forces that deform transformer wind- …

    whiterose Repository record for Power Electronic-Based Solutions for Transient-Free Energization of Traction Power Transformers (opens in a new tab)

  16. Modeling and control of current inrush in PTCR barium-lead titanate

    … here explores the relationships between inrush current and processing conditions in positive temperature coefficient of resistance (PTCR) barium-lead titanate (Ba:Pb = 0.7:0.3) doped with 0.2 mole % CeO<sub>2</sub>, with emphasis on the behavior in the negative temperature coefficient of …

    ohiolink Repository record for Modeling and control of current inrush in PTCR barium-lead titanate (opens in a new tab)

  17. Circuit breaker transient recovery voltage analysis with shunt capacitor bank configurations

    … with appropriate ratings. Capacitor banks with inrush current limiting reactors are an integral part of the power system. Capacitor banks with inrush reactors on the load side terminal of the capacitor breaker alter the TRV seen across the breaker and it is critical to carry out the TRV analysis …

    texas Repository record for Circuit breaker transient recovery voltage analysis with shunt capacitor bank configurations (opens in a new tab)

  18. Condition Monitoring of Electrolytic Capacitors for Power Electronics Applications

    … capacitor faults on the capacitor voltage and current waveforms are investigated through experiments. It is also experimentally demonstrated that faults in the capacitor can be detected by monitoring the capacitor voltage and current. Various ESR estimation based detection techniques available …

    gatech Repository record for Condition Monitoring of Electrolytic Capacitors for Power Electronics Applications (opens in a new tab)

  19. An Analysis on the Circuit Breaking Phenomenon of High-Temperature Superconductor Circuit Breaker (HTSCB)

    … arc characteristics of HTSCB under the high current condition. The arc model can then be inserted in different network models and analyzed for numerous system loading with over current situations and for different HTS applications. The modelling is executed on a single-phase distribution …

    auckland-tech Repository record for An Analysis on the Circuit Breaking Phenomenon of High-Temperature Superconductor Circuit Breaker (HTSCB) (opens in a new tab)

Page 1 of 4