Results 1 to 20 of 29 for “"Inrush currents."”
-
Sympathetic inrush currents in transformer energisation
… energisation causes a number of slow-front inrush current transient problems. With the increase of distributed generations with inherent high intermittency resulting in more switching events, the transformers in service are increasingly vulnerable to electrical transients. This thesis is …
-
IMPACT OF INRUSH CURRENTS AND GEOMAGNETICALLY INDUCED CURRENTS ON TRANSFORMER BEHAVIOR
… that are studied in this report are magnetic inrush currents, geomagnetically induced currents in power transformers and Over-excitation. This project develops a novel way of initializing and visualizing the flux linkage in the transformer core for studies on energization inrush currents. In …
-
Models for Calculating Residual Voltage of Induction Motors.
… source. Such switching may possibly cause inrush currents to the motors to be large enough to cause motor damage. The reason for the high inrush currents is that a voltage is being generated by the motors. This voltage is called a residual voltage. The residual voltage is generated by the …
-
The application of pole mounted amorphous core transformers to the electrical distribution network.
… to be designed at a lower peak flux density. Inrush currents are a phenomenon that occurs when a transformer is switched on. The combination of the voltage switching angle and the remnant flux lead to an overflux and subsequent saturation of the core material, this leads to a high current. The …
-
Power Electronic-Based Solutions for Transient-Free Energization of Traction Power Transformers
… seeks to develop methods to reduce or eliminate inrush currents during the energization of traction transformers. It is essential to address inrush currents without de- pending on the transformer’s design information or initial status. New energization methods are proposed to address the …
-
Black-start provision from grid-forming converters : a new network restoration paradigm
… capabilities against high network energization inrush currents, in addition to identifying suitable controllers for reliable GFC operation and black-start compatibility. To tackle these points, the investigations in this thesis begin by proposing an innovative energy management system (EMS) that …
-
Soft Started Induction Motor Modeling and Heating Issues for Different Starting Profiles Using a Flux Linkage ABC-Frame of Reference
… induction machines cause torque transients, high inrush currents, and thus heating of the machine. A popular method for starting an induction machine is applying electronically controlled soft starting voltages using series connected silicon controlled rectifiers (SCRs). A flux linkage ABC-frame …
-
The application of artificial neural networks to transformer protection
… Neural Networks to identify the magnetizing inrush currents that may occur in transformers is developed in this thesis. It is based on the fact that the magnetizing inrush current has large harmonic components. A feed-forward neural network (FFNN) has been trained using the back-propagation …
-
PERFORMANCE OF DIGITAL DISTANCE RELAY ALGORITHMS FOR PROTECTING TRANSFORMER TERMINATED LINES
… d.c. which is normally present in transient currents are among some of the characteristics of the algorithms that can be examined. Their performance can also be examined using fault data or data of transients like inrush currents which occur during switching-on of transformers. This thesis is …
-
Analysis of restricted earth fault relay application within a shunt capacitor bank design impacting on protection stability
… from the derived model including transient inrush currents and fault currents will be performed to access applicable scheme parameters. Further calculations will include the voltage setting for the restricted earth fault relay. As a result of the analysis a recommendation will be made on a …
-
Advanced control of grid-connected multilevel power electronic rectifiers
… which are completely discharged at first, large inrush currents from the grid might cause hazards. Therefore, the paper develops a pre-charge routine for building it up to steady state operation in which unity power factor control (PFC) and load voltage control are achieved.Finally, multiple …
-
Safe and Reliable Switching of Reactive Capacitor Banks in Sweden’s Industrial Sector
… project aims to evaluate methods of limiting inrush current when connecting capacitor banks to a 12.1 kV grid in an industrial environment. Traditionally, Swedish industries have connected large capacitor banks in parallel to the load for reactive power compensation, using asynchronous …
-
Operation of HVDC converters for transformer inrush current reduction
The present PhD thesis deals with transformer inrush current in offshore grids including offshore wind farms and High Voltage Direct Current (HVDC) transmission systems. The inrush phenomenon during transformers energization or recovery after the fault clearance is one of important concerns in …
-
Modelling and Performance Evaluation of the Virtual Air Gap Variable Reactor
… reactive line compensation and limiting inrush currents. A variable reactor is most commonly implemented as a thyristor controlled reactor (TCR) by switching in and out a constant reactance to achieve an averaged variable reactance. By using a virtual air gap, a continuously variable …
-
A wavelet-based restricted earth-fault power transformer differential protection
… in this work, even during faults in presence of inrush currents, whereas the conventional REF unit presented good sensitivity for turnto-ground faults, except in cases of transformer energization with turn-to-ground faults. In addition, the proposed method presented a faster detection than the …
-
Hybrid Smart Transformer for Enhanced Power System Protection Against DC With Advanced Grid Support
… at the module output, such as, ground faults, inrush currents, lightning and switching transients. The proposed strategy is evaluated on a scaled hardware prototype utilizing controller hardware-in-the-loop (C-HIL) and power hardware-in-the-loop (P-HIL) techniques. The dissertation also …
-
A Novel Frequency Control and Flexible Dynamic Boundary Microgrids to Improve Grid Resiliency and Facilitate Renewable Generation Integration
… is studied to mitigate the impact of transient inrush currents seen in dynamic boundary MGs. The adaptive virtual impedance control will not affect steady state operation nor fault ride through strategies. Lastly, a comprehensive design approach for dynamic boundary MGs is presented to help …
-
Transformer Differential Protection Under Geomagnetically Induced Current Conditions
… (GMDs). During the GMDs, geomagnetically induced currents (GICs) flow through the power transformers with grounded neutrals. The transformers subjected to the GIC experience part-cycle core saturation creating significant magnetizing current harmonics, including dominant second harmonics. The …
-
A Voltage Flicker Suppression Device for Residential Air Conditioners and Heat Pumps
In some circumstances, voltage flicker due to the inrush current of residential heat pump can be a fairly visible to the residents as a slight flashing of the household's lights during the compressor starting event. The voltage flicker problem is caused by a variable contribution from sizable …
-
Converter-based Microgrid Testing Platform Development and Fault Detection Method for Inverter-based Resources by Utilizing Instantaneous Power Theory
… to distinguish between faults and normal inrush currents in these systems.</p> <p>To deal with the varieties of IDGs, a new fault detection method by utilizing instantaneous power calculation is proposed to improve protection systems accuracy and reliability. Both active and non-active …
Page 1 of 2