Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 36 for “"Insertion Force"”.

  1. Insertion-force Control to Advance Implantation Strategies and Chronic Stability of Active Dense Brain Interfaces

    … My major effort was to measure and control axial insertion force, to minimize acute tissue damage induced during implantation, which constitutes a trigger of FBR. Insertion force measurements and computational modelling allowed to elucidate the impact of various probe features (e.g., …

    the-open-u Download PDF for Insertion-force Control to Advance Implantation Strategies and Chronic Stability of Active Dense Brain Interfaces (opens in a new tab)

  2. BIOINSPIRED SURGICAL NEEDLE INSERTION MECHANICS IN SOFT TISSUES FOR PERCUTANEOUS PROCEDURES

    … to the target accuracy is the needle insertion force that causes needle-tip deflection, tissue deformation, and tissue damage. Recently there has been tremendous interest in the medical community to develop innovative surgical needles using biologically-inspired designs. It is well …

    temple Repository record for BIOINSPIRED SURGICAL NEEDLE INSERTION MECHANICS IN SOFT TISSUES FOR PERCUTANEOUS PROCEDURES (opens in a new tab)

  3. Analytical and experimental study of robotic peg-in-hole insertion

    <p>A mathematical model of robotic peg-in-hole insertion, which relates insertion force and moment to manipulator compliance and geometric constraints, is presented. Based on this model, the effects of manipulator compliance and geometric and positional parameters on the insertion are studied. The …

    njit Repository record for Analytical and experimental study of robotic peg-in-hole insertion (opens in a new tab)

  4. A NOVEL BIOINSPIRED DESIGN FOR SURGICAL NEEDLES TO REDUCE TISSUE DAMAGE IN INTERVENTIONAL PROCEDURES

    … considered minimally invasive. However, in insertion into soft tissues such as brain and liver, the tissue damage caused by needle insertion can be very significant. From the literature, it has been known that reduction in needle insertion and extraction forces as well as tissue deformation …

    temple Repository record for A NOVEL BIOINSPIRED DESIGN FOR SURGICAL NEEDLES TO REDUCE TISSUE DAMAGE IN INTERVENTIONAL PROCEDURES (opens in a new tab)

  5. Interfacial Mechanics of Composite-coated Surgical Needle in Tissues

    … coating and investigates its impact on needle insertion mechanics. The aim is to create a less invasive needle insertion for a range of surgeries, including biopsy, thermal ablation, brachytherapy, and drug delivery. The composite coating, composed of Polydopamine (PDA), Polytetrafluoroethylene …

    temple Repository record for Interfacial Mechanics of Composite-coated Surgical Needle in Tissues (opens in a new tab)

  6. In Vivo Forces of Male Urethral Catheterization

    … study was to quantify typical urethral catheter insertion forces of male anatomy in vivo. This provided a quantitative range of forces that may be used to objectively evaluate trainees or educational simulators. A custom-made Handheld Catheter Insertion Force Assessment tool (+/- 0.29N accuracy) …

    umn Repository record for In Vivo Forces of Male Urethral Catheterization (opens in a new tab)

  7. Mechanical Characteristics of Male Urethral Catheterization: Simulator and Cadaveric Donor Study

    … a better understanding of the catheter insertion mechanical characteristics is needed to develop more realistic simulators for accurate clinical training. A custom-made Catheter Insertion Force Assessment Tool (+/- 0.25N absolute accuracy) and Position Acquisition System were used in …

    umn Repository record for Mechanical Characteristics of Male Urethral Catheterization: Simulator and Cadaveric Donor Study (opens in a new tab)

  8. Fabrication, packaging, and application of micromachined hollow polymer needle arrays

    … minimal invasiveness and pain, following the insertion of needles into the skin. The aim of this research is to demonstrate that micromachined hollow polymer needle arrays fabricated using UV lithography into micromolds, a potential batch-manufacturable process, can exhibit comparable …

    gatech Repository record for Fabrication, packaging, and application of micromachined hollow polymer needle arrays (opens in a new tab)

  9. Minimally invasive reliable implantation of ultra-flexible electrodes for non-human primates

    … the T-shape shuttle by decreasing the required insertion force. (3) A cannula can be fabricated to help a shuttle deliver NETs into a non-human primate brain by reducing the required insertion force, demonstrated with parafilm and agarose gel phantoms.

    rice Repository record for Minimally invasive reliable implantation of ultra-flexible electrodes for non-human primates (opens in a new tab)

  10. Optimization and Characterization of Lab-on-a-Chip Elements: Microfluidic Chambers and Microneedles

    … of microneedle tips provides reduced skin insertion force without compromising structural strength. Variation of skin insertion force of microneedles with change in tip sharpness has been studied, and toughness of human skin derived to be approximately 26 kJ/m². The axial and shear fracture …

    usf Repository record for Optimization and Characterization of Lab-on-a-Chip Elements: Microfluidic Chambers and Microneedles (opens in a new tab)

  11. Experimental and computational investigation of curved needle-tissue interaction under linear and curvilinear base manipulation

    … leaving the mechanics of curved needle insertion and the relative contributions of tissue deformation and frictional forces not fully understood. This dissertation investigates the mechanics of curved needle insertion through a combination of experimental studies and finite element …

    temple Repository record for Experimental and computational investigation of curved needle-tissue interaction under linear and curvilinear base manipulation (opens in a new tab)

  12. Multiscale nonlinear mechanics optimization for micromechanical interlocking structures

    … operational boundary below which van der Waals forces become design-governing, setting a geometric requirement on the μMIS engagement surface. Misalignment sensitivity analysis quantifies the insertion force amplification that radial offsets produce in cantilever arrays, producing both a …

    hawaii Repository record for Multiscale nonlinear mechanics optimization for micromechanical interlocking structures (opens in a new tab) Embargoed until 2027-06-29

  13. Predictive quality modelling of polymer and metal parts fabricated by laser-based manufacturing processes

    … for the SLS process applied for glass fiber reinforced part production. For LST study, Artificial Intelligence (AI) models were developed to predict the properties (diameter increase, insertion force and pullout force) of laser processed stainless steel 316 samples used for interference fit. …

    dcu Download PDF for Predictive quality modelling of polymer and metal parts fabricated by laser-based manufacturing processes (opens in a new tab)

  14. Automatic Microassembly System for tissue engineering- Assisted with top-view and force control

    … techniques is the lack of the implementation of force control, especially the control of the assembly force or the insertion force. This thesis develops techniques for efficient z-axis microassembly based on force control of commercially available stages. These techniques arise from an …

    nus Repository record for Automatic Microassembly System for tissue engineering- Assisted with top-view and force control (opens in a new tab) Download file for Automatic Microassembly System for tissue engineering- Assisted with top-view and force control (opens in a new tab)

  15. Penetration force measurements in the central nervous system with silicon electrodes

    … is the tissue damage that occurs during insertion of microelectrodes into the central nervous system. The damage occurs as a result of the dimpling effect that is due to the insertion force. A method which can reduce the penetration force can also reduce dimpling and the resulting tissue …

    njit Repository record for Penetration force measurements in the central nervous system with silicon electrodes (opens in a new tab)

  16. Microtacks for retinal implant applications.

    … verify the accuracy of both fabrication methods. Insertion and retention force experiments were performed on each tack design in fiber reinforced synthetic rubber and porcine eye tissue. Results show that the titanium microtack design required less insertion force and greater removal force than …

    louisville Repository record for Microtacks for retinal implant applications. (opens in a new tab)

  17. Flexible tactile digital feedback for clinical applications

    … of the inner ear frequently occurs during insertion of electrode array into the cochlea. This is strongly related to the excessive manual insertion force of the surgeon without any tool/tissue interaction feedback. The research is examined tool-tissue interaction of large prototype scale …

    aston Download PDF for Flexible tactile digital feedback for clinical applications (opens in a new tab)

  18. A novel method for post-partum IUD insertion

    … clinicians do not recommend nor provide IUD insertion immediately postpartum, due to its high expulsion rate (9% - 30%) from the uteri of post-placental (PP), postpartum mothers. Most women say this happens during daily activities. This is due to the structure of the IUD no longer confining …

    texas Repository record for A novel method for post-partum IUD insertion (opens in a new tab)

  19. Physical modeling of tools necessary for robot manipulation

    … undesirable deflections under large reaction forces. Also, models for intuitive decision surfaces for users, decision making systems, or system controllers have not been embedded or otherwise deployed effectively. The objective of this research is to suggest graphical and parametric models of …

    texas Repository record for Physical modeling of tools necessary for robot manipulation (opens in a new tab)

  20. Development of a Prototype Manufacturing Process for Reliable Optical-Fiber Based Neural Probes

    … circular cross-section minimizes friction, hence insertion force, while planar probes provide much greater design flexibility at low cost by leveraging semiconductor manufacturing technology. In this thesis, we explore the possibility of manufacturing cylindrical probes with dense thin film …

    houston Repository record for Development of a Prototype Manufacturing Process for Reliable Optical-Fiber Based Neural Probes (opens in a new tab)

Page 1 of 2