Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 81 for “"Instrument Response"”.

  1. Mathematical Treatment of Digitized Data Containing Instrument Response and Statistical Deviations

    … for the analysis of digitized data containing instrument response effects. The first method corrects the data vector by means of multiplication by the inverse response matrix. In order to accomodate large size data fields, a special effort is made to obtain expressions for the inverse. matrix …

    mcmaster Repository record for Mathematical Treatment of Digitized Data Containing Instrument Response and Statistical Deviations (opens in a new tab)

  2. Improved characterization of natural gas leak plumes using a Laplace transform approach to correct for instrument response time

    The response time of an instrument is a measure of how quickly it achieves a steady-state value in response to a step change input. The response time directly affects the accuracy of reported values when the instrument is subject to transient conditions. In methane leak surveying, methane gas …

    colostate Repository record for Improved characterization of natural gas leak plumes using a Laplace transform approach to correct for instrument response time (opens in a new tab)

  3. Utilization of Instrument Response of SuperPaveTM Mixes at the Virginia Smart Road to Calibrate Laboratory Developed Fatigue Equations

    … is approximately 100m long. The sections are instrumented with pressure cells, strain gages, time-domain reflectometry probes, thermocouples, and frost probes. The instruments were embedded as layers were built. Laboratory fatigue tests of field cores and field-mixed laboratory-compacted …

    vt Repository record for Utilization of Instrument Response of SuperPaveTM Mixes at the Virginia Smart Road to Calibrate Laboratory Developed Fatigue Equations (opens in a new tab)

  4. Performance Quantification of Interlayer Systems in Flexible Pavements Using Finite Element Analysis, Instrument Response, and Non Destructive Testing

    This study quantifies the benefits of two interlayer systems (steel reinforcing netting and a newly-designed geocomposite membrane) in different pavement applications. Steel reinforcing netting and geocomposite membrane have been installed at the Virginia Smart Road in four different sections. …

    vt Repository record for Performance Quantification of Interlayer Systems in Flexible Pavements Using Finite Element Analysis, Instrument Response, and Non Destructive Testing (opens in a new tab)

  5. A near-surface geophysical investigation of the effects of measured and repeated removal of overlying soil on instrument response

    … heterogeneities that affect geophysical instrument response. An experiment was conducted in which topography, magnetics, ground-penetrating radar (GPR), and electromagnetic induction (EM) data were collected over a defined survey line. An excavator with a modified flat-bladed bucket was …

    tamu Repository record for A near-surface geophysical investigation of the effects of measured and repeated removal of overlying soil on instrument response (opens in a new tab)

  6. Mapping Organic Molecular Motions with RF Compressed Femtosecond Electron Diffraction

    … brightness electron pulses. A minimum temporal instrument response of 420 femtoseconds (full-width-half-maximum) for 200 femtocoulomb electron bunches is reported. The instrument response is limited by the synchronization jitter between the radio-frequency waves and the laser oscillator. To …

    toronto-retro Repository record for Mapping Organic Molecular Motions with RF Compressed Femtosecond Electron Diffraction (opens in a new tab)

  7. INFORMATION EXTRACTION IN CHROMATOGRAPHY USING CORRELATION TECHNIQUES.

    … into improving data quality from analytical instrumentation has gone on for decades, only recently has research been done to improve information extraction methods. One of these methods, correlation analysis, is based upon the shifting of one function relative to another and determining a …

    arizona-thes Repository record for INFORMATION EXTRACTION IN CHROMATOGRAPHY USING CORRELATION TECHNIQUES. (opens in a new tab)

  8. The multichromatic wavelet transformation as a source identification tool for GLAST

    … incoming photon events and strong dependence of instrument response on photon energy necessitate data analysis techniques different from those used in similar areas such as X-Ray astronomy. A modified form of the continuous wavelet transformation (CWT) has been developed for use in finding point …

    washington Repository record for The multichromatic wavelet transformation as a source identification tool for GLAST (opens in a new tab)

  9. Bayesian analysis of fluorescence lifetime imaging data

    … estimates, fitting model probabilities, and instrument response extraction, the developed approach allows for future extensions which can exploit the full probability distribution. In a section of this work already pub- lished [1], Bayesian mono-exponential analysis was shown to offer robust …

    kings Repository record for Bayesian analysis of fluorescence lifetime imaging data (opens in a new tab) Download PDF for Bayesian analysis of fluorescence lifetime imaging data (opens in a new tab)

  10. Nanoscale Energy Transport Investigated with Ultrafast Electron Microscopy

    … dynamics occurring on time-scales comparable to instrument response require precise deconvolution for proper interpretation of instrinsic material response. As such, we systematically optimize photoelectron generation and collection and map the space-charge and temporal instrument-response …

    umn Repository record for Nanoscale Energy Transport Investigated with Ultrafast Electron Microscopy (opens in a new tab)

  11. Monitoring Energetic Electron Precipitation Using a Ground-based Radio Array

    … of kilometers from transmitter to receiver. Instrument response is shown to be consistent with the literature for energetic electron precipitation. Instrumental uncertainty is evaluated, revealing a random instrument uncertainty substantially less than electron precipitation signatures. The …

    calgary Repository record for Monitoring Energetic Electron Precipitation Using a Ground-based Radio Array (opens in a new tab)

  12. A refraction survey across the Canadian cordillera

    … remove the amplification caused by shot size and instrument response show the effects of recording sites on Pn amplitudes are minimal. Models derived from ray theory indicate a crust which thins from about 40 km in the Omineca Crystalline Belt to about 25 km in the Insular Trough. The average Pn …

    ubc Repository record for A refraction survey across the Canadian cordillera (opens in a new tab) Download PDF for A refraction survey across the Canadian cordillera (opens in a new tab)

  13. Validation of FWD Testing Results at the Virginia Smart Road: Theoretically and by Instrument Responses

    … flexible pavement designs and was built and instrumented with pressure cells, strain gages, thermocouples, frost probes and moisture sensors. To validate the backcalculated moduli theoretically and through instrument response, this research was conducted with following objectives: 1) to …

    vt Repository record for Validation of FWD Testing Results at the Virginia Smart Road: Theoretically and by Instrument Responses (opens in a new tab)

  14. The interplay between alternative conceptions in stoichiometry and proportionality : Developing a two-tier diagnostic instrument to investigate the impact of mathematical aptitude on chemical capability

    … of an inter-disciplinary two-tier diagnostic instrument, as well as through interviews with participants, this study explores the interplay between mathematical capability and chemical capability of students and teachers, as well as their alternative conceptions of key chemical and …

    adelaide Repository record for The interplay between alternative conceptions in stoichiometry and proportionality : Developing a two-tier diagnostic instrument to investigate the impact of mathematical aptitude on chemical capability (opens in a new tab)

  15. Chromatographic Studies Of Some Hormone And Metabolic Modulators Used For Doping In Sports

    … of these two PEDs was based on the peak area instrument response. The performance of the proposed methods was validated for linearity, accuracy, precision, sensitivity, and limits of detection (LOD) and quantification (LOQ) according to the International Council on Harmonization of Technical …

    eku Repository record for Chromatographic Studies Of Some Hormone And Metabolic Modulators Used For Doping In Sports (opens in a new tab)

  16. A Comprehensive Analysis of Station Performance for the Nevada Seismological Laboratory Network

    … are comparable to much of California, making instrumental studies of earthquakes in densely populated regions crucial for hazard mitigation and response. The Nevada Seismological Laboratory (NSL)is responsible for monitoring seismic activity in this area, and over time has installed a robust …

    unr Repository record for A Comprehensive Analysis of Station Performance for the Nevada Seismological Laboratory Network (opens in a new tab)

  17. Digital Nonlinearities and the first Epoch of Reionization Power Spectrum Limit from MWA Phase III

    … of the 21-centimeter line we must remove the instrument response from our data with a precision of a part in 10^(-5). While our calibration procedures remove the linear instrument response, nonlinear artifacts remain. We show the effects of these artifacts and identify a source: quantization …

    washington Repository record for Digital Nonlinearities and the first Epoch of Reionization Power Spectrum Limit from MWA Phase III (opens in a new tab)

  18. Improving Fluorescence Lifetime Imaging Microscopy Deconvolution Using Constrained Laguerre Basis Functions

    … is measured at a pixel. The fluorescence impulse response function (IRF) is then estimated using a deconvolution of the instrument response and the measured fluorescence time decay. Two of the challenges facing FLIM are speed of the deconvolution and the accuracy of the IRFs. The linear expansion …

    tamu Repository record for Improving Fluorescence Lifetime Imaging Microscopy Deconvolution Using Constrained Laguerre Basis Functions (opens in a new tab)

  19. Seismic attenuation of regional phases in the northern Middle East and the Tibetan Plateau

    … eliminating the influence of earthquake source, instrument response, and site responses. I have measured regional phase Q values for two continental-continental collision zones, the northern Middle East and the Tibetan Plateau. The regional phase Q is typically assumed as the intrinsic Q, whose …

    missouri Repository record for Seismic attenuation of regional phases in the northern Middle East and the Tibetan Plateau (opens in a new tab)

Page 1 of 5