Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 16 of 16 for “"Instrumental drift"”

  1. Microbial Extracellular Enzymes in Marine Sediments: Methods Development and Potential Activities in the Baltic Sea Deep Biosphere

    … proved to be the more precise method because instrumental drift over time, intrawell variation among replicates, and settling of slurry homogenate over long incubations were observed using the BioTek Cytation 3. Manually measuring fluorescence one cuvette at a time with a Promega Glomax multi …

    ut-knoxville Repository record for Microbial Extracellular Enzymes in Marine Sediments: Methods Development and Potential Activities in the Baltic Sea Deep Biosphere (opens in a new tab)

  2. Calibration and Validation of the RapidScat Scatterometer Using Natural Land Targets

    … be consistent throughout its mission life with instrumental drift less than 0.3 dB. The effectiveness of slice balancing is evaluated and found to be highly dependent on the pitch of the ISS. Understanding of the diurnal backscatter response and incidence response allow comparison of RapidScat …

    byu Repository record for Calibration and Validation of the RapidScat Scatterometer Using Natural Land Targets (opens in a new tab)

  3. Hydrogel-Integrated MIM-SERS Platforms for <i>In-Situ</i>, Spatiotemporal Profiling of <i>E. coli</i> Biofilm Responses to Chemo-Physical Perturbation

    … (ERS) used as an internal standard to reduce instrumental drift. Interventions introduced at 24 h included ampicillin (AMP), femtosecond (fs) laser-induced nanobubbles (950 nm), or their combination. Spectra consistently exhibited a band near 445 cm⁻¹, tentatively associated with …

    vt Repository record for Hydrogel-Integrated MIM-SERS Platforms for <i>In-Situ</i>, Spatiotemporal Profiling of <i>E. coli</i> Biofilm Responses to Chemo-Physical Perturbation (opens in a new tab)

  4. Geological CO2 Storage Modelling Using Micro-Gravimetry

    … for environmental interferences, while the instrumental drift remains negligible. The combination of temporal observations of the iGrav along with observations of relative spring gravimeters, obtained in special network configurations, can lead to accuracies of 1-2 µGal for the gravity …

    calgary Repository record for Geological CO2 Storage Modelling Using Micro-Gravimetry (opens in a new tab)

  5. Growth, structure, and electronic properties of molybdenum/silicon thin films by Molecular beam epitaxy (MBE).

    … due to trace surface contamination and instrumental drift, a technique was developed which used Auger measurements on bulk Si and Mo to further normalize the intensity data for the fractional-monolayer coverages of Mo. The AES results in this dissertation show that for relatively slow Mo …

    arizona-thes Repository record for Growth, structure, and electronic properties of molybdenum/silicon thin films by Molecular beam epitaxy (MBE). (opens in a new tab)

  6. Circulation-Informed Seafloor Geodetic Techniques for Understanding Plate Boundary Processes

    … provides a means of recording and correcting instrumental drift, with parallels to comparable drift issues in standard pressure sensors.

    washington Repository record for Circulation-Informed Seafloor Geodetic Techniques for Understanding Plate Boundary Processes (opens in a new tab)

  7. Geodetic and Oceanographic Aspects of Absolute versus Relative Sea-Level Change

    … of ASL. Satellite altimeters suffer from instrumental drift and thus need to be calibrated using tide gauges. This requires us to estimate the rate of RSL change at each tide gauge and convert this into an estimate of the rate of ASL change. This is done using a GPS station located at or …

    ohiolink Repository record for Geodetic and Oceanographic Aspects of Absolute versus Relative Sea-Level Change (opens in a new tab)

  8. Investigations of Southwest Pacific Intraplate and Backarc Volcanism using Traditional and Non-Traditional Isotopes

    … secondary statistical correction can account for instrumental drift between analyses. At such high precision, potential exists to resolve Fe isotope fractionation behavior in response to processes such as melting, fractionation, and metasomatism in ultramafic materials. Predictable Fe isotope …

    hawaii Repository record for Investigations of Southwest Pacific Intraplate and Backarc Volcanism using Traditional and Non-Traditional Isotopes (opens in a new tab)

  9. Thermal Metrology of Polysilicon MEMS using Raman Spectroscopy

    … efficiency, measurement uncertainty, and instrumental drift were reported and elucidated.

    gatech Repository record for Thermal Metrology of Polysilicon MEMS using Raman Spectroscopy (opens in a new tab)

  10. Enhancing Aerosol Scattering Measurements: Performance Evaluation and Quality Assurance of AirPhoton Integrating Nephelometers in the Surface Particulate Matter Network

    … regular performance evaluation to account for instrumental drift and environmental influences. This study presents a field performance evaluation of the AirPhoton integrating nephelometer within the global Surface Particulate Matter Network (SPARTAN), focusing on sensor stability and long-term …

    wustl Repository record for Enhancing Aerosol Scattering Measurements: Performance Evaluation and Quality Assurance of AirPhoton Integrating Nephelometers in the Surface Particulate Matter Network (opens in a new tab)

  11. Selenium Determination using Oxygen Mass-Shift Interference Removal Technology with LC-ICP-MS/MS

    … method development of sample preparation and instrumental considerations were completed using oxygen mass-shift interference removal technology for the ICP-QQQ. An evaluation of internal standardization for SeO+ was completed using this instrument to determine if Se reactivity with oxygen was …

    ohiolink Repository record for Selenium Determination using Oxygen Mass-Shift Interference Removal Technology with LC-ICP-MS/MS (opens in a new tab)

  12. Application of thermal ion-molecule reactions in tackling spectroscopic inferences in inductively coupled plasma mass spectrometry

    … help minimize non-spectral interferences such as instrumental drift. Using an oxygen gas flow slightly higher than 0.5 mL min-I, arsenic is converted to 75 AS160+ ion in an efficient manner whereas a potentially interfering ion, 91Zr+, is completely removed. Instead of using the most abundant Se …

    brock Repository record for Application of thermal ion-molecule reactions in tackling spectroscopic inferences in inductively coupled plasma mass spectrometry (opens in a new tab)

  13. Process control and data handling in clinical chemistry by a laboratory computer

    … (3) Calculation of results after correction for instrumental drift. (4) Output of results identified by cup number. (5) Calculation of mean and standard deviation of patient specimens. The present mode of operation removes the need for manual reading of AutoAnalyzer charts and hence reading …

    edinburgh Repository record for Process control and data handling in clinical chemistry by a laboratory computer (opens in a new tab)

  14. UV-Vis Spectrophotometric Strategies for Stormwater Analysis: Lab- and Field-Verified Multivariate Regression, Monte Carlo Assessment of Sampling Protocols, Cost and Power Budgets, and Field-Validated Best Practices

    … interval showed no operationally meaningful instrumental drift. Power budget analysis demonstrated that a UV-Vis system with an automated cleaning brush achieved battery runtimes 10 to 17 times longer than a portable autosampler on an equivalent battery capacity. Lifecycle cost analysis …

    unh-thes Repository record for UV-Vis Spectrophotometric Strategies for Stormwater Analysis: Lab- and Field-Verified Multivariate Regression, Monte Carlo Assessment of Sampling Protocols, Cost and Power Budgets, and Field-Validated Best Practices (opens in a new tab)

  15. Analysis of long-term gravity records in europe : consequences for the retrieval of small amplitude and low frequency signals including the core resonance effects

    … Ces séries permettent l’examen des améliorations instrumentales à partir de la stabilité à long terme et de la dérive instrumentale. Nous montrons que le SG est l’instrument le plus performant pour l’étude des marées de longues périodes et de faibles amplitudes. Nous montrons les résultats obtenus …

    star-france Repository record for Analysis of long-term gravity records in europe : consequences for the retrieval of small amplitude and low frequency signals including the core resonance effects (opens in a new tab)