Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 51 for “"Instrumental parameters"”
-
Investigation of column and instrumental parameters for fast gas chromatography analysis
… study involves varying a number of column and instrumental parameters in order to determine their effect on the chromatographic analysis time. The parameters which were varied include the column stationary phase film thickness, the column length, the injection volume, the split ratio, the …
-
Direct analysis of samples by mass spectrometry: From elements to bio-molecules using laser ablation inductively coupled plasma mass spectrometry and laser desorption/ionization mass spectrometry
… research that has discovered experimental and instrumental parameters that inhibit fractionation effects that occur during the quantification of elemental species in solid samples by laser ablation inductively coupled plasma mass spectrometry is described. Research that determines the …
-
Exploring expanded wavelength regions with solid state focal plane detectors
… focused on the investigation of the effects of instrumental parameters on partial least squares models by comparing the results obtained from four different spectrometers. The results indicate that instrumental parameters, such as resolution and wavelength coverage, have a larger effect on …
-
Process potentiometric sequential injection titrations
… system was optimised with respect to all instrumental parameters of the system and applied for acid-base titrations. The results obtained showed high reliability and reproducibility. The system is fully computerised, inexpensive and suitable for on-line monitoring.
-
Condições de acessibilidade dos centros acadêmicos universitários: criação de um instrumento de avaliação
… academic centers based on technical and instrumental parameters that make up the dimensions: architectural, communicational; methodological; instrumental; programmatic and attitudinal. As a result, a global indicator was presented – Indicator A6 – which testifies to how accessible the …
-
Further investigation of a kinetic model to accurately predict evaporation of gasoline
… accuracy of the model involved changes to the instrumental parameters and data analysis procedures. The feasibility of development of PPMC coefficient ranges involved comparisons of predicted reference collections of a non-gasoline ignitable liquid to chromatograms of experimentally evaporated …
-
Application of the optimal estimation method (OEM) to retrieve relative humidity from Raman Lidar backscatter measurements.
… of temperature, particle extinction and other instrumental parameters from the Raman backscatter measurements obtained by the Raman Lidar for Meteorological Observations (RALMO) located in Payerne, Switzerland. Unlike the traditional method the OEM provides a full uncertainty budget with both …
-
Novel approaches to the measurement of complex atmospheric VOC mixtures using proton transfer reaction mass spectrometry
… ionisation mechanisms and developments in the instrumental design and operation of PTR-MS for deconvolution of mixtures. A new method for the preparation and use of diffusion tube methods as gas standards is reported. Detailed investigation of the ion-molecule reactions with chloroalkanes, …
-
A Study of Imaging Modes in the Scanning Transmission Electron Microscope
… the effect. From the calculations the optimum instrumental parameters pertaining to the VG-HB 5 STEM at Glasgow University are provided. Further improvement in efficiency is achieved by the use of a segmented annular detector leading to a modified DPC imaging mode. Variation of the annular …
-
A study of the expansion of a laser produced lithium plasma using spatially and temporally resolved imaging and spectroscopic techniques
… the characterisation of new or additional instrumental parameters pertinent to the quantitative interpretation of the experimental data is explored. Using the 2.2m grazing incidence spectrometer, temperature and density profile estimates for a laser produced lithium plasma are inferred. …
-
Statistical Analysis Of Visible Absorption Spectra And Mass Spectra Obtained From Dyed Textile Fibers
… approach will also be discussed in terms of how instrumental parameters and sampling methods may influence error rates.
-
Determination of Crispness in Breaded Fried Chicken Nuggets Using Ultrasonic Technique
… breaded fried foods. Though many approaches to instrumental measurement of crispness have been made, the best measurements are still inconclusive. There is no reliable method available that can accurately measure and quantify crispness in breaded fried foods. In this study, the mechanical and …
-
Structural Analysis of Macromolecular Complexes Using Electrospray Ionization Mass Spectrometry Based Approaches
… were investigated. The optimization of MS instrumental parameters and solution conditions for stabilizing and protecting labile thiol-protected silver nanoclusters through ionization, mass analysis and detection is presented. The relatively much more stable and well characterized …
-
Part I: Application of pulse polarography and pulse anodic stripping to the determination of selected heavy metals in natural waters : part II: Application of controlled potential coulometric techniques to the determination of uranium
… stripping voltammetry is described. Optimal instrumental parameters for maximum resolution and sensitivity for simultaneous analysis of these three elements in natural waters are discussed. The interference of copper with the determination of zinc is investigated in detail. An optimal mercury …
-
Foreground Cleaning for Cosmic Microwave Background Polarimeters in the Presence of Instrumental Effects
… algorithms particularly in the presence of instrumental effects. One of the instrumental effects I focus on in this work is the frequency dependent polarization rotation effect such as the one caused by an achromatic half-wave plate (AHWP). As an example, I use the AHWP of the E and B …
-
Novel strategies and techniques for performing elemental speciation.
… limits in the mug/l range. Then by changing the instrumental parameters the instrument performed speciation analysis on different chromium complexes and identified the chromium and copper species in a simple standard mixture.
-
Investigations of the Dry Snow Zone of the Greenland Ice Sheet Using QuikSCAT
… in annual backscatter behavior. Several QuikSCAT instrumental parameters are tested as possible causes of seasonal variation in backscatter in the dry snow zone to verify the accuracy of QuikSCAT products. None of the tested parameters are found to be related to seasonal variation. Further …
-
Surface Chemical Studies of Environmental Microplastics from the Laurentian Great Lakes: Field and Laboratory Samples
… of the surface condition along with their innate instrumental parameters that include high mass resolution, high mass accuracy, high sensitivity, and potential for direct quantitative analysis. In this thesis, we analyzed environmental samples from the Great Lakes to test this initial hypothesis …
-
I. Analysis of biological specimens by proton-induced x-ray emission spectroscopy (PIXE). II. Separation and purity of carbon₆₀ and carbon₇₀.
… outlines work done on the optimization of instrumental parameters and sample preparation for the analysis of biological tissue. Cultured rabbit renal slices were used as the biological system to demonstrate the use of PIXE analysis. The renal slices were exposed to HgCl₂, CdCl₂, K₂Cr₂0₇, or …
-
Pseudo-Molecular Ion Formation by Aromatic Acids in Negative Ionization Mode Electrospray Ionization Mass Spectrometry
… of pH, concentration, injection volume, and instrumental parameters on dominant ion forms observed in the mass spectra. These ion forms correspond to a deprotonated molecular ion ([M-H]-), a hydrogen-bound dimer ion ([2M-H]-), and a sodium-bridged dimer ion ([2M-2H+Na]-). Report of the latter …
Page 1 of 3