Thermal Integrity Profiling Instrumentation Development
This thesis has shown that the development of the instrumentation necessary to provide in-situ thermal imaging for the determination of homogeneity of concrete is theoretically sound. Drilled shafts are large diameter underground cast-in-place columns that necessarily rely on sound integrity to …
-
Fluorophore studies & instrumentation development for tumour margin estimation
Surgery remains a key treatment option for tumour removal, where surgeons primarily rely on eye and touch to assess the boundary between healthy and cancerous tissue with no cellular information as guidance. There is therefore a need for a device or instrument that can be used by the surgeon in …
-
Novel nanomechanical property instrumentation development and its application to surface engineered systems
… and it is envisaged that the novel sub-ambient instrumentation will be used for the design, charaterisation and optimization of novel engineered surfaces for various environmental applications.
-
Probing the Interfaces of Semiconducting Nanoparticles using Sum Frequency Generation: Instrumentation Development and Design
<p>Since the inception and the development of high power lasers, nonlinear spectroscopy and microscopy have been pushing the boundaries for optical techniques. These techniques have changed how we understand emerging materials and revolutionized imaging capabilities. Herein is presented work which …
-
Instrumentation Development for Site-Specific Prediction of Spectral Effects on Concentrated Photovoltaic System Performance
The description of a novel device to measure the spectral direct normal irradiance is presented. The solar spectral irradiance meter (SSIM) was designed at the University of Ottawa as a cost-effective alternative to a prohibitively expensive field spectroradiometer (FSR). The latter measures …
-
Instrumentation development for coupling ion/ion reactions and ion mobility in biological mass spectrometry
<p>The development of mass spectrometry (MS) instrumentation for novel biological applications, specifically, the development of instrumentation that integrates ion/ion reaction capabilities in an ion trap (IT) with ion mobility-quadrupole-time-of-flight (IMS-q-TOF) analysis is presented. Chapter 1 …
-
Instrumentation Development For Assessing The Environment Inside Shipping Containers Of Pancreatic Islets During Air Transportation
<p>This study was conducted to obtain information on the effect of altitude on the internal environment of shipping containers for pancreatic islet cells being transported by commercial aircraft. Previous experience has shown that islet cell counts decrease after the islet cells have been …
-
Subdiffraction instrumentation development and application to the elucidation of biological systems, thin films, and organic photovoltaic devices
<p>Fluorescence and Raman instrumentation was developed to elucidate morphology, information on local environment, and material properties of target systems. Far-field fluorescence and luminescence spectroscopic measurements were performed using a pulsed super-continuum laser source and detector …
-
Instrumentation Development for Interfacial Studies and Analysis of Substrate-Supported Molecular Thin Films by Reflection High-Energy Electron Diffraction
Chemical and physical properties at interfaces play key roles in understanding a number of diverse phenomena. A better molecular-level understanding of the interfacial interactions is needed to utilize them in the potential applications. Different surface-analysis techniques have their own distinct …
-
Instrumentation requirements for TREE Effects Data Collection at the Naval Postgraduate School Flash X-ray facility
… concern to researchers at this time; therefore, instrumentation development was based primarily on the needs dictated by these devices. A brief description of the current status of wafer scale integrated devices is presented along with some basic TREE data collected on these devices.
-
MALDI-MS imaging for direct drug distribution analysis.
… within this thesis is the development and application of MALDI imaging techniques for a variety of analytical problems. The use of various software packages have been employed in the interpretation of the data acquired from MALDI experiments including, the use of statistical …
-
Advancing High-Energy Astrophysics through X-ray Spectropolarimetry and Balloon-Borne Instrumentation
… modeling, observational data analysis, and instrumentation development to address open questions in high-energy astrophysics. On the theoretical side, relativistic ray-tracing simulations test the truncated disk-hot inner flow accretion geometry against observations of Cygnus X-1, …
-
Parametric Optimization of Visible Wavelength Gold Lattice Geometries for Improved Plasmon-Enhanced Fluorescence Spectroscopy
… will allow for innovations in optical instrumentation development and the realization of more efficient optical biodetection components. Biosensors have been shown to improve the overall quality of life through real-time detection of various antibody-antigen reactions, biomarkers, …
-
Micromachined Electrical Field-flow Fractionation Systems with On-column Electrical and Resonance Light Scattering Detection Modalities
… major technological pushes in modern bioanalysis instrumentation development is the realization of efficient, miniaturized bioanalysis systems. In this work, three sizes of micromachined electrical field-flow fractionation (m-ElFFF) systems, with complementary on-column electrical and optical …
-
Instrumental Development and Implementation of Portable Membrane Inlet Mass Spectrometry for Homeland Security and Environmental Applications
… is the adaptation of benchtop analytical instrumentation for use in outdoor harsh environments. Some of the areas that stand to benefit from field instrumentation development include government agencies involved with the preservation of the environment and institutions responsible for the …
-
Design and Performance of an Automated Production Test System for a 20,000 Channel Single-Photon, Sub-Nanosecond Electronic Readout for a Large Area Muon Detector
… Per Second (GSPS) digitizer, developed by the Instrumentation Development Laboratory (IDLab), will be presented. Automated calibration routines were developed. Then, the performance of the ASIC was evaluated. In addition, the KLM detector readout electronics system was mass produced. Fully …
-
Preferences among student counselors regarding informed consent practices within counselor education.
… specifically for this study through systematic instrumentation development. Descriptive statistics highlighted participants' moderate to high ratings of perceived importance for an array of suggested content pieces for student informed consent. Participants varied among themselves and between …
-
Ocular accommodation control and adaptive optics. The development of monocular and binocular adaptive optics instrumentation for the study of accommodation and convergence, and study of the monocular accommodative response to rapid changes in dioptric stimuli.
… stimulus control using adaptive optics, the development of a monocular adaptive optics instrument for this purpose is described. The instrument is used to vary a dioptric stimulus and record the accommodation response in pilot studies and a detailed experiment, which has also been published …
-
Ocular accommodation control and adaptive optics. The development of monocular and binocular adaptive optics instrumentation for the study of accommodation and convergence, and study of the monocular accommodative response to rapid changes in dioptric stimuli.
… stimulus control using adaptive optics, the development of a monocular adaptive optics instrument for this purpose is described. The instrument is used to vary a dioptric stimulus and record the accommodation response in pilot studies and a detailed experiment, which has also been published …