Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 22 for “"Insulation Coordination"”

  1. Insulation Coordination in Modern Distribution Networks

    The appropriate analysis of the response of distribution networks against Lightning Electro Magnetic Pulse (LEMP) – originated by nearby strikes – requires the availability of accurate coupling models in order to reproduce the real and complex configuration of distribution systems. The above models …

    bologna Repository record for Insulation Coordination in Modern Distribution Networks (opens in a new tab)

  2. Insulation coordination in the Turkish e.h.v. transmission system

    This thesis reviews the line insulation coordination practices of Turkish Electricity Transmission Company with special focus on E.H.V. transmission line towers’ top geometry and ground clearances. In respect of this, the national regulation, “Elektrik Kuvvetli Akım Tesisleri Yönetmeligi”, is …

    metu Repository record for Insulation coordination in the Turkish e.h.v. transmission system (opens in a new tab)

  3. Enhancing the reliability of electric transportation motors through insulation coordination and improved qualification

    … compromises in the motor reliability. For the insulation specialists the challenge will be critical as the use of wide-bandgap converters (WBG, based on SiC and GaN switches) and the higher operating voltages expected for the next generation drives will enhance the electrical stresses to …

    bologna Repository record for Enhancing the reliability of electric transportation motors through insulation coordination and improved qualification (opens in a new tab)

  4. Optimization of location and number of lightning arresters in 420 kV substations in Turkish high voltage electricity system

    Insulation coordination is defined as the selection of the dielectric strength of equipment in relation to the voltages which can appear on the system for which the equipment is intended and taking into account the service environment and the characteristics of the available protective devices. In …

    metu Repository record for Optimization of location and number of lightning arresters in 420 kV substations in Turkish high voltage electricity system (opens in a new tab)

  5. Avaliação da suportabilidade dielétrica do isolamento em ar e coordenação de isolamento de linhas de transmissão

    … methodology to aid in the process of insulation coordination, a fundamental stage of the TL design. In this methodology, the dimensions of the tower are defined according to the maximum risk of failure, by a statistical method of insulation coordination. With its application, …

    brazil-uerj Repository record for Avaliação da suportabilidade dielétrica do isolamento em ar e coordenação de isolamento de linhas de transmissão (opens in a new tab)

  6. Coordenação de isolamento para transitórios de manobra considerando a forma de onda da sobretensões

    This work develops a new insulation coordination procedure for transmission lines, considering the influence of the individual characteristics of switching overvoltage waves on the insulation strength. The purpose is to assess how the waveshapes of the transient overvoltages affect the risk of …

    brazil-ufmg Repository record for Coordenação de isolamento para transitórios de manobra considerando a forma de onda da sobretensões (opens in a new tab)

  7. Investigation of Lightning-Initiated Flashover Faults in Medium Voltage Overhead Lines - Modelling and Experimental Evaluation

    … by the actual volt-time curve of the line insulation whereas the arcing phenomenon is represented by the dynamic arc model. A complete model of the experimental set-up is developed in Alternative Transients Program–Electromagnetic Transients Program (ATP-EMTP) and the experimental results …

    aalto Repository record for Investigation of Lightning-Initiated Flashover Faults in Medium Voltage Overhead Lines - Modelling and Experimental Evaluation (opens in a new tab)

  8. Use of expert systems in the preliminary design of high voltage DC point-to-point transmission systems

    … expert system modules concerned with AC design, insulation coordination, and reliability, all of which form the TRANSEPT family of expert systems for the preliminary design of point-to-point power transmission systems. The domain knowledge of the design of HVDC transmission systems is first …

    mcgill Repository record for Use of expert systems in the preliminary design of high voltage DC point-to-point transmission systems (opens in a new tab)

  9. Constructional design, manufacturing and evaluation of high power density medium frequency transformer prototypes

    … The important technical data regarding the insulation characteristics of insulation materials was examined at nominal wave shape and frequency considered for the transformer application and the insulation coordination of the transformers was updated accordingly. At the same time, to prepare …

    chalmers Repository record for Constructional design, manufacturing and evaluation of high power density medium frequency transformer prototypes (opens in a new tab)

  10. intelligent power system design

    … such as point-to-point transmission design, insulation coordination as well as protection system and substation design. In order to validate the proposed concepts as well as the object-oriented paradigm adopted for their realization, a substation design module (SIDE) was fully developed and …

    mcgill Repository record for intelligent power system design (opens in a new tab)

  11. Estudo da aplicação do aterramento ressonante em redes de distribuição com ramais monofásicos e bifásicos

    … presence of single-phase and two-phase branches, insulation coordination, high-impedance faults and broken wires, and the inuence of the saturable core coil.

    brazil-ufmg Repository record for Estudo da aplicação do aterramento ressonante em redes de distribuição com ramais monofásicos e bifásicos (opens in a new tab)

  12. Μοντελοποίηση και συντονισμός διατάξεων προστασίας έναντι υπερτάσεων: εφαρμογή σε συστήματα φόρτισης ηλεκτρικών οχημάτων

    … of this doctoral dissertation, the modeling and coordination of surge protective devices are investigated. A generalized and experimentally validated methodology was developed for the electrical characterization and modeling of surge protective devices of different technologies, based on …

    greece Repository record for Μοντελοποίηση και συντονισμός διατάξεων προστασίας έναντι υπερτάσεων: εφαρμογή σε συστήματα φόρτισης ηλεκτρικών οχημάτων (opens in a new tab)

  13. Modelagem do efeito corona em linhas de transmissão utilizando o método FDTD para o estudo de sobretensões transitórias

    … indicates that the consideration of corona in insulation coordination studies would lead to less severe overvoltages, providing benefits for the protection of the equipment installed in substations.

    brazil-ufmg Repository record for Modelagem do efeito corona em linhas de transmissão utilizando o método FDTD para o estudo de sobretensões transitórias (opens in a new tab)

  14. Um estudo de modelos de máquinas elétricas submetidas a surtos de tensão

    The insulation systems used in the stator windings of electrical machines are not designed, for reasons of space, performance and economics, to withstand high voltage surges resulting from lightning, switching or faults in the power system. Specific standards are used to define the capability of …

    brazil-ufmg Repository record for Um estudo de modelos de máquinas elétricas submetidas a surtos de tensão (opens in a new tab)

  15. Improved Lightning Performance for 132 kV OHL

    … 132 kV grid is investigated using statistical insulation coordination in the softwares LPE and PSCAD. The optimal placement of the shield wires on towers located on flat ground is determined. Furthermore, the shield wire configuration of a new portal tower with two shield wires and typical …

    chalmers Repository record for Improved Lightning Performance for 132 kV OHL (opens in a new tab)

  16. Lightning electromagnetic field coupling to overhead transmission line networks and to buried cables

    … As a consequence, for a correct protection and insulation coordination, the accurate estimation of lightning-induced overvoltages is essential. In addition, sensitive electronic components used in power and communication systems may suffer logic upset or damage at significantly lower levels of …

    epfl Repository record for Lightning electromagnetic field coupling to overhead transmission line networks and to buried cables (opens in a new tab)

  17. Διερεύνηση του φαινομένου της εκκένωσης κορώνα σε γραμμές μεταφοράς

    … the overvoltage waveform must be considered in insulation coordination studies, where the attenuation and distortion of overvoltage surges propagating along overhead transmission lines due to corona effects is concerned.

    greece Repository record for Διερεύνηση του φαινομένου της εκκένωσης κορώνα σε γραμμές μεταφοράς (opens in a new tab)

  18. Modeling and Simulation of Transient Fault Response at Lillgrund Wind Farm when Subjected to Faults in the Connecting 130 kV Grid

    … stage of future wind farms when performing insulation coordination and determining the protection settings. A model of the Lillgrund wind farm and a part of the connecting 130 kV grid were built in PSCAD/EMTDC. The farm consists of 48 Siemens SWT-2.3-93 2.3 MW wind turbines with full power …

    chalmers Repository record for Modeling and Simulation of Transient Fault Response at Lillgrund Wind Farm when Subjected to Faults in the Connecting 130 kV Grid (opens in a new tab)

Page 1 of 2