  1. ANALYSIS AND IMPEDANCE-BASED DETECTION OF ELECTROMAGNETIC COIL INSULATION DEGRADATION

    … applications are safety-critical. Failure of the insulation that protects the windings in electromagnetic coils is a significant cause of coil failure and can have severe implications for system reliability. An effective insulation health monitoring program can reduce maintenance and replacement …

    maryland Repository record for ANALYSIS AND IMPEDANCE-BASED DETECTION OF ELECTROMAGNETIC COIL INSULATION DEGRADATION (opens in a new tab)

  2. Modeling and Testing of Insulation Degradation due to Dynamic Thermal Loading of Electrical Machines

    … temperatures. The aging of the Electrical Insulation System (EIS) in electrical machines is caused by these dynamic temperatures, namely high average temperatures and temperature cycles. In addition, the degradation of EIS affects the lifetime of the electrical machine. In this thesis, …

    lund Repository record for Modeling and Testing of Insulation Degradation due to Dynamic Thermal Loading of Electrical Machines (opens in a new tab) Download PDF for Modeling and Testing of Insulation Degradation due to Dynamic Thermal Loading of Electrical Machines (opens in a new tab)

  3. Prediction of insulation degradation of distribution power cables based on chemical analysis and electrical measurements

    … with the prediction of medium voltage cable insulation condition. Different kinds of electrical measurements and chemical analyses are tested to find out the most representative combination. A large scale test program was carried out on field aged XLPE-insulated and oil-paper insulated …

    aalto Repository record for Prediction of insulation degradation of distribution power cables based on chemical analysis and electrical measurements (opens in a new tab)

  4. Modeling and Detection of Stator Winding Insulation Degradation in VSI-fed Electric Machines Under High dv/dt

    … voltages for motor operation. Motor’s winding insulation undergoes additional electrical stress due to high voltage slew rate (dv/dt) resulted from the use of VSI, which may cause accelerated insulation degradation. To investigate and quantify this electrical stress, various modeling techniques …

    concordia Download PDF for Modeling and Detection of Stator Winding Insulation Degradation in VSI-fed Electric Machines Under High dv/dt (opens in a new tab)

  5. Principal component analysis (PCA) as a statistical tool for identifying key indicators of nuclear power plant cable insulation degradation

    … statistical method to identify key indicators of degradation in nuclear power plant cable insulation. Seven kinds of single-point data were measured on cross-linked polyethylene (XLPE) that had undergone aging at various doses and dose rates of gamma radiation from a cobalt 60 source, and at …

    iastate Repository record for Principal component analysis (PCA) as a statistical tool for identifying key indicators of nuclear power plant cable insulation degradation (opens in a new tab)

  6. Polymer damage mitigation--predictive lifetime models of polymer insulation degradation and biorenewable thermosets through cationic polymerization for self-healing applications

    … extensively in the aerospace field as a wire insulation coating. Because of the vast amount of electrical wiring used in aerospace constructions and the potential for electrical and thermal failure, this work develops mathematical models for both the thermal degradation kinetics as well as a …

    iastate Repository record for Polymer damage mitigation--predictive lifetime models of polymer insulation degradation and biorenewable thermosets through cationic polymerization for self-healing applications (opens in a new tab)

  7. Online Condition Monitoring of Stator Winding Insulation State of Electric Machines in Electrified Vehicles

    … control. However, short circuit faults and insulation failures remain prevalent, accounting for approximately 30% of motor failures. Given the uncertainties surrounding insulation degradation, detecting degradations of insulation in an early stage can help prevent major failures. Therefore, …

    concordia Download PDF for Online Condition Monitoring of Stator Winding Insulation State of Electric Machines in Electrified Vehicles (opens in a new tab)

  8. Robust stator insulation prognosis technique for inverter-driven machines

    "Stator insulation degradation is one of the most common causes for failure in an electric machine. As wide bandgap device become more popular for inverter topologies, electrical stress increases and insulation failure becomes a more significant concern. Short circuits formed from degraded …

    msu Repository record for Robust stator insulation prognosis technique for inverter-driven machines (opens in a new tab)

  9. Probabilistic Cable Aging Diagnosis And Prognosis With Reflectometry And Capacitance Methods

    … stresses, which generally lead to aging and degradation of cable insulation. It is reported that some cables with a projected lifetime of 40 years need to be replaced in 10-15 years. Poorly maintained aged cables can adversely affect power delivery and lead to catastrophic events, such as …

    south-carolina Repository record for Probabilistic Cable Aging Diagnosis And Prognosis With Reflectometry And Capacitance Methods (opens in a new tab)

  10. Condition monitoring and analysis of a permanent magnet synchronous machine drive system

    … parameters found to detect parametric changes. Insulation condition is assessed by monitoring the high-frequency slot capacitance and high slot resistance. Demagnetization faults are detected by monitoring changes in the inductance.In order to improve permanent magnet synchronous machine …

    msu Repository record for Condition monitoring and analysis of a permanent magnet synchronous machine drive system (opens in a new tab)

  11. Partial discharge diagnostics in medium voltage cables

    … of circuit faults resulting directly from insulation degradation and breakdown due to ageing. This will lead to customer interruption and regulatory penalties. A program for the wholesale replacement of vast cable networks is impracticable, not economically viable and most likely …

    strathclyde Repository record for Partial discharge diagnostics in medium voltage cables (opens in a new tab)

  12. Online partial discharge measurement in a high noise environment

    … and allow for the trending and monitoring of insulation degradation. Furthermore, specific strategies for PD measurement and analysis are developed.

    manitoba Repository record for Online partial discharge measurement in a high noise environment (opens in a new tab)

  13. Development of an online thermal degradation monitoring and failure estimation system for nuclear grade instrumentation and control cables

    … (SSTDR) is used to characterize cable degradation. The reflected signal responses and the Risk matrix at localized hot spots are displayed on a Human-Machine Interface (HMI). Regression-based degradation models were developed to establish relationships between the received signal …

    uoit Repository record for Development of an online thermal degradation monitoring and failure estimation system for nuclear grade instrumentation and control cables (opens in a new tab)

  14. Insulation Assembly Effects on Performance of Medium-Voltage Cable Terminations

    … localized electric field enhancement may lead to insulation degradation, partial discharge activity, and premature failure. Sources of the enhanced fields may appear due to improper assembling of the terminations, especially on field conditions. This study investigates electric field distributions …

    chalmers Repository record for Insulation Assembly Effects on Performance of Medium-Voltage Cable Terminations (opens in a new tab)

  15. Online condition monitoring of HV cable circuits

    … it is an important metric and a clear symptom of insulation degradation.</p> <p>Acoustic methods have been widely applied for partial discharge detection in power apparatus. Initial studies were undertaken to assess the suitability of PVDF as a piezoelectric sensor for detecting acoustic emission …

    soton Download PDF for Online condition monitoring of HV cable circuits (opens in a new tab)

  16. Insulation Resistance Monitoring for HVDC systems in automotive applications

    … push toward ever-higher voltages, reliable insulation resistance monitoring (IRM) becomes critical to ensure safety, prevent insulation degradation, and maintain system availability. Key IRM performance parameters include common-mode and delta-voltage excursions (which drive dielectric …

    chalmers Repository record for Insulation Resistance Monitoring for HVDC systems in automotive applications (opens in a new tab)

  17. A Study on the Impacts of Wide-Bandgap Devices on Turn-to-Turn Insulation Performance in Hairpin Winding for Electric Vehicle Traction Motors

    … motor reliability, particularly in the winding insulation system. Therefore, it is crucial to study and characterize the effects of higher voltage levels and WBG device-based drives on hairpin winding insulation. Turn-to-turn insulation is the most vulnerable point in motor stators. Power …

    waterloo Repository record for A Study on the Impacts of Wide-Bandgap Devices on Turn-to-Turn Insulation Performance in Hairpin Winding for Electric Vehicle Traction Motors (opens in a new tab)

  18. Monitoring and Prognosis of Plant Components

    … models trained using failure data. Motor insulation degradation was also considered, both experimentally and using an analytical formulation. 'Virtual trending' of internal parameters, such as the insulation breakdown voltage, was also considered to establish alarm levels in terms of a …

    ut-knoxville Repository record for Monitoring and Prognosis of Plant Components (opens in a new tab)

  19. A Study of High Frequency Voltage Effects in Medium Voltage Cable Terminations

    … (compact) cable terminations are susceptible to insulation degradation and eventual flashover failure, under high frequency harmonic stresses. As such, the present work studies high frequency voltage effects in cross-linked polyethylene cable terminations, and their relationship to stress grading …

    waterloo Repository record for A Study of High Frequency Voltage Effects in Medium Voltage Cable Terminations (opens in a new tab)

  20. Health Monitoring Techniques for High Availability Drives

    … requirements on availability involves monitoring degradation associated with machine failure, diagnosing the mode of failure and predicting into the future to a possible time to failure. Broad multi-disciplinary knowledge is required to understand drive ageing and implement monitoring systems. …

    whiterose Download PDF for Health Monitoring Techniques for High Availability Drives (opens in a new tab)