Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 21 for “"Integrated electrodes."”.

  1. Elektroporacijos taikymas mikrofluidinėse "organas - luste" sistemose ir jos poveikio vertinimas TEEV metodu /

    … property changes. However, the stability of integrated electrodes in microfluidic systems remains one of the main technical challenges, especially under high-voltage pulsed electric fields. In this study, COC-based microfluidic chips with gold electrodes formed by physical vapor deposition …

    vilnius Repository record for Elektroporacijos taikymas mikrofluidinėse "organas - luste" sistemose ir jos poveikio vertinimas TEEV metodu / (opens in a new tab)

  2. 3D-Printed Fluidic Devices and Incorporated Graphite Electrodes for Electrochemical Immunoassay of Biomarker Proteins

    … low-cost 3D-printed flow-through devices with integrated electrodes modified with gold nanoparticles (AuNPs) for electrochemical immunoassays of S100B, a biomarker protein related to conditions like skin cancer and brain injuries. Flow-through devices are fabricated from photocurable-resin …

    etsu Repository record for 3D-Printed Fluidic Devices and Incorporated Graphite Electrodes for Electrochemical Immunoassay of Biomarker Proteins (opens in a new tab) Download PDF for 3D-Printed Fluidic Devices and Incorporated Graphite Electrodes for Electrochemical Immunoassay of Biomarker Proteins (opens in a new tab)

  3. Improvements to iontophoresis devices for transdermal glucose monitoring

    … in in vitro RIexperiments using the developed AC-integrated electrodes to the standard electrodeswithout AC. The extracted glucose was quantified using glucose assay kits.Furthermore, this study involved embedding a biosensor in the electrode system toallow direct glucose measurements.In vitro RI …

    strathclyde Repository record for Improvements to iontophoresis devices for transdermal glucose monitoring (opens in a new tab)

  4. Integrated Circuits for Rapid Sample Processing and Electrochemical Detection of Biomarkers

    … overcome this limitation by designing a range of integrated devices to optimize the flux of the analyte to the sensor by increasing the effective analyte concentration, shortening the required diffusion distance, and confining the analyte in close proximity to the sensor. We couple these devices …

    toronto-retro Repository record for Integrated Circuits for Rapid Sample Processing and Electrochemical Detection of Biomarkers (opens in a new tab)

  5. Rapid prototyping, performance characterization, and design automation of droplet-based microfluidic devices

    … devices are biocompatible and can accommodate integrated electrodes for sophisticated droplet manipulations, such as droplet sensing, sorting, and merging. Next, we leverage low-cost rapid prototyping to characterize the performance of microfluidic flow-focusing droplet generators. …

    bu Repository record for Rapid prototyping, performance characterization, and design automation of droplet-based microfluidic devices (opens in a new tab)

  6. Droplet-based microfluidics for screening and single-cell analysis

    … programmability by manipulating droplets using integrated electrodes. However, this precise control and manipulation significantly decreases the system throughput. Therefore, this thesis aims to integrate droplet and digital microfluidic systems to offer valuable insights into the potential of …

    concordia Download PDF for Droplet-based microfluidics for screening and single-cell analysis (opens in a new tab)

  7. The Nanoaquarium: A Nanofluidic Platform for in SiTu Transmission Electron Microscopy in Liquid Media

    … with lab-on-chip technology; and on-chip integrated electrodes for sensing and actuation. The fabrication process is described, with an emphasis on direct wafer bonding. Experimental results involving direct observation of colloid aggregation using an aqueous solution of gold nanoparticles …

    penn Repository record for The Nanoaquarium: A Nanofluidic Platform for in SiTu Transmission Electron Microscopy in Liquid Media (opens in a new tab)

  8. Design, Fabrication, and Validation of a Highly Miniaturized Wirelessly Powered Neural Implant

    … and recording possible, is to disconnect the electrodes from the base, so that they can be arbitrarily placed, using a syringe, freely in the nervous system. To overcome the challenges of system miniaturization, we propose the “microbead”, an ultra-small neural stimulating implant, that is …

    jhu Repository record for Design, Fabrication, and Validation of a Highly Miniaturized Wirelessly Powered Neural Implant (opens in a new tab)

  9. Development of a Prototype Manufacturing Process for Reliable Optical-Fiber Based Neural Probes

    … the fabrication of cylindrical probes with 4-integrated electrodes on 60 µm optical fibers at EIPBN-2013. These proof-of-concept optrodes were used to detect photo-simulated electrical activity of neurons in the primary visual cortex of Olemur garnettii, a non-prosimian primate. However, …

    houston Repository record for Development of a Prototype Manufacturing Process for Reliable Optical-Fiber Based Neural Probes (opens in a new tab)

  10. Mathematical Modeling of an Electrode-Integrated Fixed-Bed Bioreactor for Treatment of Sulfate

    … characteristics for an effective electrode-integrated fixed-bed bioreactor for sulfatetreatment. The bioreactor stimulates and sustains biological sulfate reduction and simultaneously facilitates the subsequent removal of the reduced sulfide by applying iron electrolysis under low electrical …

    umn Repository record for Mathematical Modeling of an Electrode-Integrated Fixed-Bed Bioreactor for Treatment of Sulfate (opens in a new tab)

  11. Advancing atomic force microscopy-scanning electrochemical microscopy based sensing platforms for biological applications

    … Integration of amperometric biosensors at tip-integrated electrodes recessed from the apex of the AFM tip further enhances the versatility of such bifunctional probes. Of particular interest to this work was the detection of adenosine triphosphate (ATP) at a cellular level, since ATP is …

    gatech Repository record for Advancing atomic force microscopy-scanning electrochemical microscopy based sensing platforms for biological applications (opens in a new tab)

  12. Microsensor system for the metabolic monitoring in cancer cell culture

    … sensor system consists of a glass chip with integrated electrodes, enabling the integration of various electrochemical measurement principles. On top of the glass chip a PMMA tube is fixed, building the cell culture well. Microsensor chips were fabricated in an efficient full-wafer process. …

    freiburg-diss Repository record for Microsensor system for the metabolic monitoring in cancer cell culture (opens in a new tab)

  13. Hot electron-induced electrochemiluminescence studies with different cathode materials and electrode geometries

    … reactions that are not achieved at active metal electrodes in aqueous solution using traditional electrochemistry. The research revealed that the substrate material of the electrode can be quite freely chosen. The substrate material does not necessarily have to be a conductor, if a thin …

    aalto Repository record for Hot electron-induced electrochemiluminescence studies with different cathode materials and electrode geometries (opens in a new tab)

  14. Microscale hemispherical shell resonating gyroscopes

    … hemispherical shell with self-aligned deep electrodes for driving, sensing and quadrature control of the gyroscope. This monolithic process consists of seven lithography steps and combines 3D micro-structure with curved surfaces with the HARPSS process to create capacitive electrodes with …

    gatech Repository record for Microscale hemispherical shell resonating gyroscopes (opens in a new tab)

  15. An integrated-optic current sensor for relaying and metering in high-voltage power systems

    … and tested here using a Rogowski coil and an integrated-optic Pockels cell (IOPC). The Rogowski coil generates a low-level voltage signal in proportion to the derivative of the primary current. A fully passive integrator is constructed from ultrastable components, permitting integration in the …

    ubc Repository record for An integrated-optic current sensor for relaying and metering in high-voltage power systems (opens in a new tab) Download PDF for An integrated-optic current sensor for relaying and metering in high-voltage power systems (opens in a new tab)

  16. Development of an integrated aerosol drug delivery device for an in vitro airway barrier on a chip platform

    … technology. The drug delivery device can be integrated with the airway barrier on a chip platform to deliver aerosolised drugs mimicking the way we inhale viruses and compounds to create a more physiologically relevant challenge model. The majority of drug delivery devices interface only with …

    soton Download PDF for Development of an integrated aerosol drug delivery device for an in vitro airway barrier on a chip platform (opens in a new tab)

  17. The Design of Wearable Technology: Addressing the Human-Device Interface Through Functional Apparel Design

    … several variables involved in the use of garment-integrated contact (not adhesive) electrodes for bio-monitoring, an input modality that creates a low cognitive load for the user. Garment-integrated electrodes were designed to replace the medical standard adhesive electrodes, to increase the …

    cornell Repository record for The Design of Wearable Technology: Addressing the Human-Device Interface Through Functional Apparel Design (opens in a new tab)

  18. Physical Encapsulation of Interface Bilayers

    … droplet support, the use of externally supported electrodes to electrically probe the network, and the requirement that in order to form DIB networks, aqueous volumes must be individually dispensed and arranged. The approach presented in this document is to provide increased interactions between …

    vt Repository record for Physical Encapsulation of Interface Bilayers (opens in a new tab)

  19. Design and Implementation of VO2-Based Tunable Windows and Microelectromechanical Optical Shutters for Emissivity Modulation

    … The 400μm windowfeatures a VO2thin film with integrated electrodes for actuation and sensing. The phasetransition was induced by resistive heating, while the electrical resistivity and optical trans-mittance (for near IR wavelength of 1550 nm) of the VO2thin film were monitored …

    msu Repository record for Design and Implementation of VO2-Based Tunable Windows and Microelectromechanical Optical Shutters for Emissivity Modulation (opens in a new tab)

  20. Fabrication and Characterization of a Disk Ring Shaped Dual Nanometer-Sized Electrode and Its Application to Generation-Collection.

    … on the fabrication and characterization of integrated dual nanometer-sized electrodes. The electrodes are made of closely spaced nanometer-sized platinum and gold achieved by inserting and pulling platinum wire in cylindrical glass pipette plated with gold. Cyclic voltammetry has been used …

    etsu Repository record for Fabrication and Characterization of a Disk Ring Shaped Dual Nanometer-Sized Electrode and Its Application to Generation-Collection. (opens in a new tab) Download PDF for Fabrication and Characterization of a Disk Ring Shaped Dual Nanometer-Sized Electrode and Its Application to Generation-Collection. (opens in a new tab)

Page 1 of 2