Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 41 for “"Intensity measurement"”.
-
Muon Intensity Measurement with the Majorana Demonstrator
… has been done to determine the differential muon intensity. The complex geometry of the interlacing detector panels requires the use of Monte Carlo methods to accurately determine the Demonstrator’s sensitivity to muons approaching from a range of angles. Combining the detector geometry with the …
-
The application of wave based techniques to intensity measurement in beams and plates
The estimation of flexural wave intensity requires a knowledge of the internal forces present within the material, and these may be related to the spatial derivatives of displacement through the use of simple bending theories. A fundamental problem of intensity measurement lies in the estimation of …
-
A Method of X-Ray Intensity Measurement and the Structures of Some Tropolones
Part I: A new photographic method for the measurement of the intensities of X-ray diffraction spectra is described. In principle it is similar to the positive print method, but photographic reversal is used instead of printing. Film processing conditions are given. The accuracy of this method is …
-
Comparative Study and Design of Economical Sound Intensity Probe
The theory of sound intensity measurement using the two-microphone method was first developed in the late 1970s. Even though the measurements were limited by the technology of the time, the theory was straight-forward and considerable attention was given to improving precision during testing or …
-
Behavior of enteric pathogens on wheat grains during tempering and evaluation of inactivation methods prior to milling
… of pathogen was found based on the fluorescent intensity measurement. Chlorinated water had been used in the tempering solution in mills to control mold and yeast growth. When hard wheat grains were treated with 800ppm chlorinated water as a tempering over 18 hours, pathogen population changed …
-
Microscopy of Gold Microcrystals by Coherent X -Ray Diffractive Imaging
… the structure of materials. Inherent in these measurements is the loss of phase information in the intensity measurement; the so-called ""phase problem."" Third generation synchrotrons provide X-ray beams with coherence volumes on the cubic micron size scale, allowing the coherent illumination …
-
Healing from within: Assessing the effects of the Four Rs of Self-Forgiveness on physiological health outcomes
… physiological findings may reflect limited task intensity, measurement sensitivity, or the use of a healthy sample. Still, the intervention demonstrated strong psychological benefits, supporting the Four Rs model as an effective emotional healing tool. Future research could be done to incorporate …
-
Advanced Seismic Risk Assessment of California Box-Girder Bridges Using Emerging Modeling Techniques and Innovative Risk Models
… structural seismic demand and ground motion intensity measurement, are examined. A new method called modified multiple adaptive regression splines (M-MARS) is proposed to construct the PSDM. Following is the development of four-level fragility models, from low-level component fragilities to …
-
Resonance fluorescence and superfluorescence of intersubband transitions
… of the usual Mollow triplet. In particular, the intensity of the central peak in the fluorescence spectrum becomes a function of the electron coherence, allowing access to the coherence time of a quasi two-dimensional electron gas through a fluorescence intensity measurement. Moreover, while …
-
Noise source location in the built environment, using a simple microphone array
… must be found. Recently, near field noise intensity measurement has been the popular method for noise source location in buildings. This method of using intensity studies requires a grid of readings to be taken. An alternative method, the one used in this work, employs a different strategy. …
-
Plenoptic camera : theory and experimental results
… software that can process the measured image intensity, reconstruct this into a full resolution image, and to develop a depth map from its corresponding rendered image. The plenoptic camera is a specialized imaging system designed to acquire spatial, angular, and depth information in a single …
-
A ground-based real-time remote sensing system for diagnosing nitrogen status in cotton plants
… Each output of the sensor represents the intensity measurement of spectral reflectance in that waveband. To avoid measurement error that may be induced by variations in spectral characteristic under natural illumination of the plant canopy; a modulated light source was used to illuminate …
-
Instrumentation and methods for frequency-domain and multimodal near-infrared spectroscopy
… (NIRS) device and for multimodal brain measurements was implemented. Different techniques were applied to human and newborn lamb brain studies. A method to detect light leakage in NIRS measurements was developed. The FD instrument, developed at the Helsinki University of Technology was …
-
Quantifying Contact Workloads in Professional Male Rugby Union by Implementing an Action Design Research Framework
… of the total workload in rugby union, but measurement difficulties mean it’s typically not included in rugby workload assessments. Objective: To design a system that defines and quantifies contacts during a professional rugby union game. Design: We implemented an action design research …
-
Photon flux monitor for a mono-energetic gamma ray source
… and tested for use at the Duke University High Intensity Gamma Source, where the photon beam produced is essentially mono-energetic but it is not tagged. Direct counting of the number of photons using a high-efficiency detector is not possible because of the high photon fluxes expected. …
-
High precision diagnostics of ultrashort high-power laser for strong-field QED experiments
… field for the first time. However, the precision measurement of processes in SFQED experiments is challenged by shot-to-shot intensity fluctuations of ultrashort laser pulses.<br>This thesis describes the high-precision on-shot intensity measurement of ultrafast high-power laser pulses required by …
-
GENE REGULATORY NETWORK INFERENCE USING K-NEAREST-NEIGHBOR BASED MUTUAL INFORMATION AND THREE-NODE NETWORK CLASSIFICATION USING DIMENSIONALITY REDUCTION AND MACHINE LEARNING
… data (for example, normalized fluorescence intensity measurement of gene expression levels) is sensitive to data size, correlation strength and underlying distributions, and often requires laborious and, at times, ad hoc optimization. Results: In this work, we first show that estimating MI …
-
A Time-Gated Fluorescence Instrument and Its Applications Using Mn-Doped I(II)-III-VI Nanocrystal Probes
… of a low-cost, portable, time-gated fluorescence intensity measurement instrument were developed with the primary aim of utilizing Mn-doped I(II)-III-VI nanocrystals (Mn:AgZnInS/ZnS and Mn:CuZnInS/ZnS core/shell) as long-lifetime fluorescent probes for sensing applications. These nanocrystals have …
-
Transient sound intensity measurements for evaluating the spatial information of sound fields in reverberant enclosures
… of an efficient, accurate and easy to perform measurement method. The main objectives of the present study are, first; to review known and speculative room-acoustic indicators for use in assessing reverberant spaces such as concert halls, opera houses, multi-purpose halls and churches. Second, …
-
Energy transfer and electron conduction in the fluid transpiration arc column
… heavy particle temperature, and, (4) continuum intensity measurement for electron density and temperature. High-speed motion pictures give qualitative measure of the plasma volume and its reaction to a material probe. The results indicate that while somewhat higher electrical conductivities are …
Page 1 of 3