Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 433 for “"Intensity-Modulated"”

  1. Kilovoltage Intensity Modulated Radiotherapy

    … reported mechanism for delivering kilovoltage intensity modulated radiotherapy. This required the invention and production of a novel 6 x 6 cm2 multi-rod collimator (MRC) with an in-house control system. The MRC was mounted between a decommissioned portal imager and several phantoms loaded with …

    wayne-thes Repository record for Kilovoltage Intensity Modulated Radiotherapy (opens in a new tab)

  2. Intensity-Modulated Spectroscopy Instrument and Its Applications

    We have successfully built and tested an intensity-modulated spectroscopy (IMS) instrument that is centered around a commercial lock-in amplifier, which can be used to perform intensity-modulated spectroscopy (IMS) up to a frequency of 250 kHz. We have tested our instrument on a commercial …

    whiterose Repository record for Intensity-Modulated Spectroscopy Instrument and Its Applications (opens in a new tab)

  3. Intensity modulated proton therapy in lung cancer

    … focused on the treatment planning aspect of intensity modulated proton therapy (IMPT) in conventionally fractionated radiotherapy for NSCLC. The subsequent parts that followed aimed at identifying patient groups where PBT is likely to be of highest clinical benefit. Therefore, the aims of …

    oxford Repository record for Intensity modulated proton therapy in lung cancer (opens in a new tab)

  4. Intensity modulated radiotherapy for skull base meningioma

    … standard dose regimens. In recent years Intensity-Modulated Radiotherapy (IMRT) has been developed, and can deliver highly conformal dose distributions with sharp dose gradients, making dose escalation a possibility for many tumours, including those located in the skull base. The aim of …

    auckland-ms Repository record for Intensity modulated radiotherapy for skull base meningioma (opens in a new tab)

  5. Intensity Modulated Proton Therapy for Hepatocellular Carcinoma

    … the advantages and drawbacks of using intensity modulated proton therapy (IMPT) in the treatment of hepatocellular carcinoma (HCC) and compares this treatment modality with photon stereotactic body radiation therapy (SBRT). One patient, previously treated with photon SBRT, has been …

    chalmers Repository record for Intensity Modulated Proton Therapy for Hepatocellular Carcinoma (opens in a new tab)

  6. Subcarrier intensity modulated free-space optical communication systems

    … (FSO) system based on the phase shift keying pre-modulated subcarrier intensity modulation (SIM). The results are theoretically and experimentally compared with the classical On-Off keying (OOK) modulated FSO system in the presence of atmospheric turbulence. The performance analysis is based on …

    northumbria Repository record for Subcarrier intensity modulated free-space optical communication systems (opens in a new tab)

  7. EPID dosimetry in intensity modulated radiation therapy applications.

    Electronic Portal Imaging Devices (EPIDs) can be used for dosimetric purposes, provided that an appropriate dosimetric calibration is used. However, in most studies published so far, transmitted dose maps, measured using EPIDs, are used under limited conditions only and further investigation is …

    adelaide Repository record for EPID dosimetry in intensity modulated radiation therapy applications. (opens in a new tab)

  8. Absolute Dose Verification in Intensity Modulated Radiation Fields

    Made available in DSpace on 2017-07-06T18:42:30Z (GMT). No. of bitstreams: 3 Garada_Masab_H_PhD.pdf: 57446279 bytes, checksum: a6d94fd190db1906d111368f39a7abd5 (MD5) Garada_Masab_H_PhD_ABS.pdf: 696014 bytes, checksum: 6c65f47008bf7b7d7d58407b7e25c4a8 (MD5) license.txt: 4813 bytes, checksum: …

    uiuc Repository record for Absolute Dose Verification in Intensity Modulated Radiation Fields (opens in a new tab)

  9. Absolute Dose Verification in Intensity Modulated Radiation Fields

    … a method for measuring the absolute dose for Intensity modulated radiation fields. An accurate verification and physical measurement of the computed absolute dose in Intensity modulated radiation therapy (IMRT) is a challenging task. There are many sources of errors associated with IMRT …

    uiuc Repository record for Absolute Dose Verification in Intensity Modulated Radiation Fields (opens in a new tab)

  10. Optimization, Delivery and Evaluation of Intensity Modulated Arc Therapy

    Intensity modulated arc therapy (IMAT) is a radiation therapy technique whereby the shape of the cone beam of radiation changes as it rotates around the patient. This is in contrast to other more commonly delivered forms of advanced radiation therapy, Intensity Modulated Radiation Therapy (IMRT) or …

    uwo Repository record for Optimization, Delivery and Evaluation of Intensity Modulated Arc Therapy (opens in a new tab)

  11. Optimization of Scanning Parameters in Intensity Modulated Proton Therapy

    As scanning systems for intensity modulated proton therapy (IMPT) gain prevalance in the market and make their way into cancer centers, there is a significant need for focused basic research. Understanding of the implications of active scanning and its many new parameters on radiation treatment …

    heid-diss Repository record for Optimization of Scanning Parameters in Intensity Modulated Proton Therapy (opens in a new tab)

  12. Risk-adapted Optimization in Intensity Modulated Proton Therapy (IMPT)

    Due to the pronounced dose gradients generated by proton beams, proton treatment plans can be very sensitive to treatment uncertainties. However in IMPT many different solutions of the inverse problem exist which result in dose distributions of comparable quality. This thesis investigates methods …

    heid-diss Repository record for Risk-adapted Optimization in Intensity Modulated Proton Therapy (IMPT) (opens in a new tab)

  13. Investigations into static multileaf collimator based intensity modulated radiotherapy

    Intensity Modulated Radiation Therapy (IMRT) is a modern radiotherapy treatment technique used to obtain highly conformal dose distributions. The delivery of IMRT is commonly achieved through the use of a multileaf collimator (MLC). One of the hindrances at present to the widespread use of IMRT is …

    unsw Repository record for Investigations into static multileaf collimator based intensity modulated radiotherapy (opens in a new tab)

  14. Dose verification of rotating collimator intensity modulated radiation thearpy

    A novel method of delivering Intensity Modulated Radiation Therapy (IMRT) has been proposed in which the entire multileaf collimator (MLC) is rotated between each segment. Current linear accelerators (linacs) are not designed for IMRT delivery with collimator rotation therefore extensive quality …

    ubc Repository record for Dose verification of rotating collimator intensity modulated radiation thearpy (opens in a new tab)

  15. An Investigation Of Uncertainties In Intensity Modulated Radiation Therapy

    Introduction: The treatment of cancer using intensity modulated radiation therapy (IMRT) is complex, involving many sub-processes to commission a treatment platform and treat patients. Uncertainties within the individual sub-process can lead to inaccurate treatments and sub-optimal patient …

    wayne-thes Repository record for An Investigation Of Uncertainties In Intensity Modulated Radiation Therapy (opens in a new tab)

  16. Optimization Approaches for Intensity Modulated Proton Therapy Treatment Planning

    … while minimizing damage to healthy tissues. Intensity Modulated Proton Therapy (IMPT) is a type of radiation therapy that utilizes protons to irradiate the tumor. The unique physical properties of protons enable precise control over the radiation dose distribution within the tumor and more …

    calgary Repository record for Optimization Approaches for Intensity Modulated Proton Therapy Treatment Planning (opens in a new tab)

  17. Computational methods for beam angle optimization in intensity modulated radiotherapy

    Este trabalho aborda um problema de otimização relacionado com o tratamento de estruturas tumorais, conhecido por Radioterapia de Intensidade Modulada. Este método de tratamento baseia-se na incidência de radiação raio-X, que visa destruir as células malignas, preservando, na medida do possível, os …

    coimbro Repository record for Computational methods for beam angle optimization in intensity modulated radiotherapy (opens in a new tab)

  18. The Advantages of Collimator Optimization for Intensity Modulated Radiation Therapy

    … a new algorithm for collimator optimization for intensity modulated radiation therapy (IMRT) that minimizes the x-jaw gap (CAX) and the area of the jaws (CAA) for each treatment field. A retroactive study on the effects of collimator optimization of 20 patients was performed by comparing metric …

    fau Repository record for The Advantages of Collimator Optimization for Intensity Modulated Radiation Therapy (opens in a new tab)

Page 1 of 22