Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 73 for “"Intensity-modulated radiation therapy (IMRT)"”.
-
Monte Carlo simulation of modern techniques of intensity modulated radiation therapy (IMRT)
Clinical delivery of radiation therapy faces an old dilemma: how to maximize the dose to the tumoral cells while spearing the surrounding healthy tissue. Along this path two major innovations will most likely play an important role in the future. The first has to do with the employment of so far …
-
Intensity Modulated Radiation Therapy (IMRT) versus Conventional Methods in Treatment of Breast Cancer
Made available in DSpace on 2017-07-06T18:48:10Z (GMT). No. of bitstreams: 3 Garada_Masab_H_MS.pdf: 25651236 bytes, checksum: 73bdf7e5f39d5df868694b4da036d02f (MD5) Garada_Masab_H_MS_ABS.pdf: 430262 bytes, checksum: 605229f2df5957921ac144e978f18848 (MD5) license.txt: 4813 bytes, checksum: …
-
Automated Intensity Modulated Radiation Therapy (IMRT) using fast dose and fluence calculations and Reinforcement Learning
<p>Ionizing radiation is a powerful tool in the fight against cancer. Its potentially lethal effect on cells can halt or even irradicate tumor growth by destroying malignant tumor cells. This is a positive effect on unwanted tumors, but a negative one for surrounding healthy tissue. The goal of …
-
The fabrication of an acrylic repositioning stent for use during intensity modulated radiation therapy (IMRT) : a feasibility study
Objectives: Radiation therapy is one of the main treatment modalities for malignant head and neck cancers. To minimize the damage to normal tissues during radiation therapy, various methods of stabilization have been utilized, including thermoplastic facemasks and bite blocks. Our goal is to assess …
-
Evaluation of Intensity Modulated Radiation Therapy (Imrt) Delivery Error Due to Imrt Treatment Plan Complexity and Improperly Matched Dosimetry Data
Intensity modulated radiation therapy (IMRT) is a technique that delivers a highly conformal dose distribution to a target volume while attempting to maximally spare the surrounding normal tissues. IMRT is a common treatment modality used for treating head and neck (H&N) cancers, and the presence …
-
DOSIMETRIC COMPARISON OF THREE-DIMENSIONAL CONFORMAL RADIATION THERAPY (3D-CRT), INTENSITY MODULATED RADIATION THERAPY (IMRT) AND VOLUMETRIC MODULATED ARC THERAPY (VMAT) FOR DISTAL ESOPHAGEAL CANCER TREATED WITH EXTERNAL RADIATION
Purpose/Objectives: Intensity Modulated Radiation Therapy (IMRT) and Volumetric Modulated Arc Therapy (VMAT) provide advantages in delivery of radiation allowing conformality of delivered dose to the planning target and reducing dose to organs at risk (OAR), however, at the potential cost of low …
-
Beam angle and fluence map optimization for PARETO multi-objective intensity modulated radiation therapy treatment planning
… optimizes beam angles and fluence patterns in intensity-modulated radiation therapy (IMRT) treatment planning using a powerful genetic algorithm. We also investigate various objective functions and compare several parameterizations for modeling beam fluence in terms of fluence map complexity, …
-
Benders decomposition and an IP-based heuristic for selecting IMRT treatment beam angles
To optimize the beam angle and fluence map in Intensity Modulated Radiation Therapy (IMRT) planning, we apply Benders decomposition as well as develop a two-stage integer programming-based heuristic. Benders decomposition is first implemented in the traditional manner by iteratively solving the …
-
An Investigation Of Uncertainties In Intensity Modulated Radiation Therapy
Introduction: The treatment of cancer using intensity modulated radiation therapy (IMRT) is complex, involving many sub-processes to commission a treatment platform and treat patients. Uncertainties within the individual sub-process can lead to inaccurate treatments and sub-optimal patient …
-
Automating Intensity Modulated Radiation Therapy Treatment Planning by using Hierarchical Optimization
The intensity modulated radiation therapy (IMRT) optimizes the beam’s intensity to deliver the prescribed dose to the target while minimizing the radiation exposure to normal structures. The IMRT optimization is a complex optimization problem because of the multiple conflicting objectives in it. …
-
Error analysis of Tight Probability Bounds for Hausdorff Random Variables in Cancer Radiation Therapy Planning
Intensity-Modulated Radiation Therapy (IMRT) plays a key role in cancer treatment by enabling precise delivery of high radiation doses to tumours while reducing exposure to nearby healthy organs. Inverse planning for IMRT is commonly evaluated through Dose–Volume Histograms (DVHs), which summarize …
-
A sensitivity-driven greedy approach to fluence map optimization in intensity-modulated radiation therapy
Intensity-modulated radiation therapy (IMRT) is a state-of-the-art technique for administering radiation to cancer patients. The goal of a treatment is to maximize the radiation absorbed by the tumor and minimize that absorbed by the surrounding critical organs. Since a plan can almost never be …
-
Rapid Re-optimization of Prostate Intensity-Modulated Radiation Therapy Using Regularized Linear Programming
… linear programming approach for re-optimizing a intensity modulated radiation therapy (IMRT) treatment plan, in order to compensate for inter-fraction tissue deformations. Different formulations of the problem involve different constraints, but a common constraint that is difficult to handle …
-
Dosimetric properties and radiation hardness of the storage phosphor europium doped potassium chloride for radiation therapy dosimetry
… dose distributions associated with modern radiation therapy techniques, such as intensity modulated radiation therapy (IMRT). In particular, reusability provides medical physicists a degree of confidence in dosimetric measurements through the acquisition of benchmarking datasets and through …
-
Investigation of automatic treatment planning (ATP) optimization using an Adaptative Neuro-Fuzzy AI system
… planning (ATP) plays a critical role in modern radiation therapy, where optimizing treatment plans to achieve high-quality dosimetric outcomes remains a challenging task. This dissertation investigates the development and implementation of an Adaptive Neuro-Fuzzy Inference System (ANFIS) for ATP …
-
Effects of pelvic 3D-CRT versus IMRT radiation therapy on circulating pro-inflammatory cytokines in high risk Prostate Cancer patients
This study examined the effects of pelvic radiation therapy on the levels of circulating pro-inflammatory cytokines (cPIC) in high-risk prostate cancer patients, who received pelvic radiation therapy delivered either by 3-dimensional radiation therapy pelvic (3D CRT) or intensity-modulated …
-
2d dose measurement using a flat panel EPID
The increasing use of intensity modulated radiation therapy (IMRT) to deliver conformal radiation treatment has prompted the search for a faster and more cost effective quality assurance (QA) system. The standard technique relies on the use of film for two-dimensional dose distribution …
-
Geometry-based Constraint Generation for Large-scale Radiation Therapy Treatment Planning
Intensity-Modulated Radiation Therapy (IMRT) is a high precision radiotherapy with many beams that have different intensities to accurately irradiate a tumor/cancerous cells considering minimization of the dose to surrounding normal tissues. Different optimization methods are developed to achieve …
-
An evaluation of patient-specific IMRT verification failures
… Centre (VIC), the clinical verification of Intensity Modulated Radiation Therapy (IMRT) treatment plans involves comparing Portal Image (PI) -based three-dimensionally reconstructed (EPIDose) dose distributions to planned doses calculated using the Pencil Beam Convolution (PBC) algorithm. …
-
A Portal imager-based patient dosimetry system
A technique for the in vivo dose verification of intensity modulated radiation therapy (IMRT) has been developed. An electronic portal image, calibrated in terms of absolute dose, is acquired for each radiation field following transmission through the patient at the time of treatment. For an IMRT …
Page 1 of 4