Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 30 for “"Inter turn short-circuit"”
-
Fault Tolerant Control of PMSM with Inter-turn Short Circuit Fault
… and FT control can be applied on PMSM with inter-turn short circuit (SC). Its theoretical base and practical performance are presented and its strength over previous methods are come up with.
-
Model predictive torque control of an induction motor enhanced with an inter-turn short circuit fault detection feature
… and electric drives. The reason behind this interest in MPC is the advantages that it offers: intuitive and flexible algorithm, fast dynamic response, ease of handling converter nonlinearities, and system constraints, to name a few. In this thesis, MPC is applied to the torque control of an …
-
Methodology for Modeling and Detection of inter-turn short-circuit faults of a Permanent Magnet Assisted Synchronous Reluctance Motor in Electric vehicles
… fiable pour la détection des défauts de court-circuit inter-spires par l'ACP. Pour estimer la sévérité du défaut, nous avons développé un modèle analytique de la pente de la fonction de décision CUSUM de T². À partir de ce modèle analytique, nous avons pu estimer le défaut dans des données sans …
-
Offline detection of stator inter-turn faults in induction motors based on common-mode frequency response
… an important topic. This project aims to monitor inter-turn faults in induction motors offline by measuring the motor's common-mode impedance. This paper uses a vector network analyzer to conduct sweep-frequency measurements on the common-mode ports of the tested induction motor. Under a unified …
-
Detecção e diagnóstico de falhas em motores de indução
… to detect and diagnose electrical faults (stator inter-turn short circuit and broken rotor bars) and mechanical faults (unbalance and shaft misalignments) for three phase induction machines. This approach starts by obtaining the best patterns for fault detection and symmetrical models for the …
-
Incipient fault diagnosis in squirrel-cage induction motors
… method for detecting rotor broken-bars and inter-turn short-circuit faults in induction motors is introduced based on electromagnetic field laws governing the operation and performance of induction machines. The basis of this new method is to monitor the orientation of the axis of the …
-
Design of an interior permanent magnet synchronous machine with a wide speed range for electric vehicle applications
Interior Permanent Magnet Synchronous Machines (IPMSMs) are commonly used for electric vehicle traction applications due to their high power density and efficiency. The maximum speed that an electric machine can achieve is limited by electrical and mechanical constraints. Therefore, the machine's …
-
Analysis and Fault Tolerant Control of a Five-Phase Axial Flux Permanent Magnet Synchronous Machine
… coils are covered with epoxy resin afterward, inter-turn short circuit risk, which is the most common stator fault in electrical machines, is completely eliminated. Therefore, in this study, the main focus is the analysis and mitigation of winding open-circuit fault. Another advantage of the …
-
Multi-objective design, optimization, and condition monitoring of high-performance electric machines for electric propulsion
… with a simple and robust structure, and the interior permanent magnet (IPM) machine with a high torque density and efficiency. For SRMs, an active current profiling technique integrated multi-objective analytical design and optimization is proposed to generate the optimal design in terms of …
-
On the different magneto-mechanical waves in faulty induction motors
… considered in this thesis are broken bars, inter-turn short circuit and dynamic eccentricity. The reason of choosing these faults is because they are the most common source of problems for this type of motor.The thesis provides a set of both analytical and computational models. The …
-
Emulation of Faults in Permanent Magnet Synchronous Machines
… primarily catastrophic faults in PMSMs is the inter-turn short circuit fault in a stator coil. Hence, PMSM behavior should be studied in the event of this fault. It is essential to have a machine model that is accurate enough to study such fault scenarios. An advancement of this idea is to …
-
Gêmeo digital para manutenção inteligente de motores de indução
… machine windings, a condition that precedes inter-turn short-circuit faults. Within the framework of Industry 4.0, an intelligent online monitoring system is proposed based on data integration and advanced data-driven modeling techniques. The approach utilizes the Digital Twin to dynamically …
-
Condition Monitoring and Fault Detection for Electrical Machines Using Advanced Sensing Techniques Based on Fibre Bragg Gratings
… Optical fibre is immune to electromagnetic interference (EMI) which is an advantage but limits its direct use for magnetic field sensing. A magnetostrictive transducer, terfenol-D was bonded to FBG to form a composite sensor - FBG-T. The FBG-T was inserted into an acrylic tube - which is …
-
A Triple Redundant 3x3-phase Fault Tolerant Permanent Magnet Synchronous Reluctance Machine Drive
… electrical faults, including the worst single turn short circuit, and is optimised to maximise the efficiency in healthy conditions whilst satisfying the electrical, thermal and mechanical constraints. To analyse and realise a fault tolerant machine drive, fault modelling and fault detection …
-
Current-, force-, and vibration-based techniques for induction motor condition monitoring
… such as broken rotor bars, broken end ring, inter-turn short circuit, bearing and eccentricity failures, were created. A real dynamic eccentricity was also created. Moreover, different supply sources were used. The measurements supported the analytical and numerical results.
-
New control strategy for permanent magnet synchronous generator (PMSG) wind turbine
… by designing an advanced control strategy. 2. Inter-turn fault detection at early stage. In the first section of this thesis, a Sliding Mode Control (SMC) based scheme is proposed for a variable speed, direct-driven Wind Turbine Conversion System (WTCS) equipped with Permanent Magnet …
-
Fault Analysis of Permanent Magnet Synchronous Machines for Safety Critical Applications
… models under various fault conditions, including inter-turn short circuit (SC). It is shown that the delta-connected winding has better fault tolerance due to higher output torque under one phase open-circuit fault and lower inter-turn SC current when the mitigation measure -- 3-phase terminal …
-
Detection of faults in a scaled down doubly-fed induction generator using advanced signal processing techniques.
… to make provision for implementing stator inter-turn short-circuit faults (ITSCF), rotor ITSCF and static eccentricity (SE) faults in the laboratory environment. The micromachine has been assessed under the healthy and faulty states, both before and after incorporating a converter into the …
-
Reconnaissance des défauts de la machine asynchrone : application des modèles d’intelligence artificielle
… concèdent tout de même des défauts (ex : court-circuit entre spires, barre rotoriques rompues) menant à des arrêts non planifiés. Par conséquent, les industries manufacturières investissent des ressources importantes afin de les éviter avec des programmes de maintenance qui sont partiellement …
-
Υπολογισμός ηλεκτρομαγνητικών μεγεθών και πρόβλεψη συμπεριφοράς μιας σύγχρονης μηχανής με έκτυπους πόλους σε περιπτώσεις σφαλμάτων με τη χρήση της μεθόδου πεπερασμένων στοιχείων
… pole synchronous generator during two kinds of short-circuits. In particular, we studied the case of short circuit in the supply of the excitation winding of the synchronous machine when it is connected to an infinite bus and either the rotor speed was absolutely constant, or a simple PI- …
Page 1 of 2