Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 23 for “"Inter-storey drift"”.

  1. Analytical study on upgrading the seismic performance of nominally ductile RC frame structures using different rehabilitation techniques

    … lateral deflection, ductility demand, and inter-storey drift are the most commonly used damage state indices. The objective of this study is to analytically investigate the effectiveness of different rehabilitation patterns in upgrading the seismic performance of existing non-ductile RC …

    concordia Download PDF for Analytical study on upgrading the seismic performance of nominally ductile RC frame structures using different rehabilitation techniques (opens in a new tab)

  2. Seismic Performance and Shear Strengthening of Precast Hollow-core Floors

    … common flooring system in New Zealand's multi-storey building stock. Due to their extrusion manufacturing process, these floor units lack transverse shear reinforcement, making them prone to non-ductile failure mechanisms during earthquakes. The 2016 M-7.8 Kaikoura earthquake showed that these …

    auckland-ms Repository record for Seismic Performance and Shear Strengthening of Precast Hollow-core Floors (opens in a new tab)

  3. Strain Rate Effects on a Ductile Moment Resisting Frame with RBS Connection Subjected to Seismic Ground Motions

    … while only a slight decrease in mean predicted inter-storey drift is observed when strain rate dependent material properties are used in analyses. It is observed that MRF with RBS connections can experience a maximum strain rate up to 0.30 per second. The strain hardening factor at RBS center is …

    carleton Repository record for Strain Rate Effects on a Ductile Moment Resisting Frame with RBS Connection Subjected to Seismic Ground Motions (opens in a new tab)

  4. Αντισεισμικός σχεδιασμός επίπεδων μεταλλικών διασυνδεδεμένων πλαισίων με χρήση τριών νέων μεθόδων

    … as to induce certain damage levels in terms of inter- storey drift ratio (IDR) and local ductility of the frame members (μ). According to SEAOC, target damages are linked with various performance levels. As a next step of the procedure, modal damping ratios that correspond to first four modes, …

    greece Repository record for Αντισεισμικός σχεδιασμός επίπεδων μεταλλικών διασυνδεδεμένων πλαισίων με χρήση τριών νέων μεθόδων (opens in a new tab)

  5. Seismic performance of plane moment resisting frames with concrete filled steel tube columns and steel I beams

    … a databank with the response quantities of interest. Based on regression analysis, simple formulae for estimating the maximum roof displacement, the maximum inter-storey drift ratio, the maximum rotation ductility along the height of the frame and the behavior factor are developed.Comparison …

    greece Repository record for Seismic performance of plane moment resisting frames with concrete filled steel tube columns and steel I beams (opens in a new tab)

  6. Mitigating torsional irregularity using cross laminated timber-reinforced concrete hybrid system

    … on buildings with torsional irregularity, a four-storey reinforced concrete (RC) structure with torsional irregularity is considered for Vancouver seismicity condition. SAP2000 software is used to conduct Linear Dynamic Analysis (LDA) and Non-Linear Time History Analysis (NLTHA) using eight …

    ubc Repository record for Mitigating torsional irregularity using cross laminated timber-reinforced concrete hybrid system (opens in a new tab) Download PDF for Mitigating torsional irregularity using cross laminated timber-reinforced concrete hybrid system (opens in a new tab)

  7. Seismic performance of CLT structures with base isolation

    … (base-shear, acceleration of the top story, inter-story drift) of base-isolated buildings to that of a reference CLT structure with fixed base. The SAP2000 software was used to conduct the nonlinear time history analysis of 3-, 6-, and 12-story CLT structures under three types of ground …

    uvic Repository record for Seismic performance of CLT structures with base isolation (opens in a new tab)

  8. Semiactive Friction Connections for Seismic Control of Multi-Storey Buildings

    … for control of the seismic response of multi-storey buildings, and the mechanisms behind their performance. Passive and semiactive systems are novel strategies used to reduce the seismic demand in structural systems by increasing the energy dissipation capacity and altering the dynamic …

    whiterose Download PDF for Semiactive Friction Connections for Seismic Control of Multi-Storey Buildings (opens in a new tab)

  9. Experimental evaluation of the seismic performance of hollow-core floors and retrofits

    … floor retrofits were tested under bi-directional inter-storey drift loading. The tested floors exhibited an early onset of cracking in the unreinforced webs of the hollow-core units at 0.4% –0.5% inter-storey drift. With increasing drifts, the web cracks also tended to become shallower (i.e. <<45 …

    auckland-ms Repository record for Experimental evaluation of the seismic performance of hollow-core floors and retrofits (opens in a new tab)

  10. The influence of structural details, geotechnical factors and environs on the seismic response of framed structures.

    … base or shallow foundations with soil structure interaction). A range of frames, of varying geometry, are considered which mobilise different amounts of inter-storey drift, local rotation and global rotation response. The influence of soil structure interaction (SSI) and frame rigidity (i.e. the …

    dundee Repository record for The influence of structural details, geotechnical factors and environs on the seismic response of framed structures. (opens in a new tab) Download PDF for The influence of structural details, geotechnical factors and environs on the seismic response of framed structures. (opens in a new tab)

  11. System Level Interactions and Floor Diaphragm Out-of-Plane Stiffness Effects on the Lateral Response of Light Frame Wood Shear Walls

    … is significantly influenced by system-level interactions that are not fully captured by conventional design approaches. In particular, the impact of floor diaphragm out-of-plane stiffness on the lateral behaviour of wood shear walls, and its role in mitigating cumulative deformations along …

    ottawa-retro Repository record for System Level Interactions and Floor Diaphragm Out-of-Plane Stiffness Effects on the Lateral Response of Light Frame Wood Shear Walls (opens in a new tab)

  12. Element Exchange Algorithms for Optimum Viscous Damper Placement in Buildings

    … for three case studies include (1) an eight-storey RC MRF building where the centre of mass (CM) is deliberately varied to test the optimised designs’ usability against symmetric and asymmetric structures, (2) a ten-storey RC MRF building used to validate the usability of optimised design at …

    auckland-ms Repository record for Element Exchange Algorithms for Optimum Viscous Damper Placement in Buildings (opens in a new tab)

  13. Performance of shape memory alloy reinforced concrete frames under extreme loads

    … Canada are taken into consideration. For each storey type, three different reinforcement detailings have been considered, namely: i) steel reinforcement only (Steel RC); ii) SMA rebar used in the plastic hinge region of the beams and steel rebar in other regions (Steel-SMA RC); and iii) the …

    ubc Repository record for Performance of shape memory alloy reinforced concrete frames under extreme loads (opens in a new tab) Download PDF for Performance of shape memory alloy reinforced concrete frames under extreme loads (opens in a new tab)

  14. Semi-Active Control of Post-tensioned Steel Frames

    … for improving the seismic behaviour of multi-storey steel frame buildings. Three control approaches were proposed to improve the dynamic behaviour of post-tensioned frames: (i) energy dissipation approach which aims to increase the energy dissipation capacity of the frame, (ii) stiffness …

    whiterose Download PDF for Semi-Active Control of Post-tensioned Steel Frames (opens in a new tab)

  15. Network-synthesis-based identification methodology for passive vibration suppression system design

    … IFL and 2PT1NG networks are applied to a three-storey building to reduce its inter-storey drift. The GIFN network is used to design hydraulically interlinked suspensions for vehicles. Simulation results show that the proposed approach is effective in identifying beneficial vibration suppression …

    bristol Repository record for Network-synthesis-based identification methodology for passive vibration suppression system design (opens in a new tab) Download PDF for Network-synthesis-based identification methodology for passive vibration suppression system design (opens in a new tab)

  16. Αντισεισμικός σχεδιασμός επίπεδων μεταλλικών πλαισίων με ιδιομορφικούς συντελεστές συμπεριφοράς και τρεις στάθμες επιτελεστικότητας

    … records have been scaled properly in order the interstorey drift or ductility demands to comply with the targeted performance levels, as they are specified in SEAOC2000 or FEMA. The purpose of this research is the construction of an equivalent, linear multi - degree of freedom system, which …

    greece Repository record for Αντισεισμικός σχεδιασμός επίπεδων μεταλλικών πλαισίων με ιδιομορφικούς συντελεστές συμπεριφοράς και τρεις στάθμες επιτελεστικότητας (opens in a new tab)

  17. Seismic behaviours of adjacent building structures on liquefied soil

    … of isolated (in consideration of soil-structure-interaction, SSI) and adjacent structures (in consideration of structure-soil-structure interaction, SSSI) with shallow foundations on liquefiable soil. Consideration is given to the influence of foundation types, relative dynamic characteristics of …

    dundee Repository record for Seismic behaviours of adjacent building structures on liquefied soil (opens in a new tab)

  18. Optimum Seismic Design of RC Frames Using Multi-Level Performance-Based Design Method

    … the initial material usages (costs) of multi-storey RC frames, while minimising structural damage by satisfying multiple performance objectives. The proposed methodology is characterised by computational efficiency, as optimum results can typically be achieved within a few iterative steps. …

    whiterose Download PDF for Optimum Seismic Design of RC Frames Using Multi-Level Performance-Based Design Method (opens in a new tab)

  19. Highly deformable confined rubberised concrete elements for seismic applications

    … the behaviour of short columns in a one-bay one-storey building made of conventional RC. The building collapsed with the brittle failure of the short column at a small drift ratio of 0.37% for the unrestrained column. The experimental results are used to validate a numerical model in Abaqus, …

    whiterose Download PDF for Highly deformable confined rubberised concrete elements for seismic applications (opens in a new tab)

  20. Framework for Seismic Vulnerability Assessment of RC High-rise Wall Buildings

    … stiffness-based damping matrix is employed. A 30-storey reference wall building located in the multiple-scenario earthquake-prone city of Dubai (UAE) is fully designed and numerically modelled as a case study to illustrate the proposed framework. A total of 40 real earthquake records, representing …

    whiterose Download PDF for Framework for Seismic Vulnerability Assessment of RC High-rise Wall Buildings (opens in a new tab)

Page 1 of 2