Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 20 for “"Intercalibration"”.

  1. Intercalibration of QuikSCAT and OSCAT Land Backscatter

    The Ku-band SeaWinds-on-QuikSCAT scatterometer (QuikSCAT) operated continuously from 1999 to 2009. Though its primary mission was to estimate global ocean winds, QuikSCAT has proven useful in a variety of geophysical studies using land backscatter measurements. The end of the primary QuikSCAT …

    byu Repository record for Intercalibration of QuikSCAT and OSCAT Land Backscatter (opens in a new tab) Download PDF for Intercalibration of QuikSCAT and OSCAT Land Backscatter (opens in a new tab)

  2. Application of Tissue Equivalent Proportional Counter (TEPC) in Intercalibration with NaI (Tl) Spectrometer

    Tissue equivalent proportional counters (TEPCs) are recognized as standard instrument for cosmic radiation dose measurement because it can separate gamma and neutron spectra in mixed field microdosimetry. HAWK TEPC was employed in the project as a reference instrument to measure the cosmic …

    carleton Repository record for Application of Tissue Equivalent Proportional Counter (TEPC) in Intercalibration with NaI (Tl) Spectrometer (opens in a new tab)

  3. Towards An Improved Long-term Data Record From The Advanced Very-high Resolution Radiometer: Evaluation, Atmospheric Correction, And Intercalibration

    … selection of stable areas suitable for satellite intercalibration and for the derivation of recalibration coefficients. The evaluation of the original and recalibrated record showed that for most cases the recalibrated record performed better.

    maryland Repository record for Towards An Improved Long-term Data Record From The Advanced Very-high Resolution Radiometer: Evaluation, Atmospheric Correction, And Intercalibration (opens in a new tab)

  4. Multimetric assessment of freshwater macroinvertebrate communities in Flanders, Belgium

    … along all member states in Europe, regional intercalibration exercises were envisaged by the WFD for each quality element and for each category of water body. For river macroinvertebrates, the relevant regional intercalibration exercise for Flanders was coordinated by the so-called …

    ghent Repository record for Multimetric assessment of freshwater macroinvertebrate communities in Flanders, Belgium (opens in a new tab)

  5. ΠΡΟΣΔΙΟΡΙΣΜΟΣ ΧΛΩΡΙΩΜΕΝΩΝ ΥΔΡΟΓΟΝΑΝΘΡΑΚΩΝ ΣΕ ΟΡΓΑΝΙΣΜΟΥΣ

    … DISTINGUISHED FOR ITS ACCURACY IN INTERNATIONAL INTERCALIBRATION EXERCISES.

    greece Repository record for ΠΡΟΣΔΙΟΡΙΣΜΟΣ ΧΛΩΡΙΩΜΕΝΩΝ ΥΔΡΟΓΟΝΑΝΘΡΑΚΩΝ ΣΕ ΟΡΓΑΝΙΣΜΟΥΣ (opens in a new tab)

  6. A novel approach to estimate active carbon flux using the micronekton biomass spectra

    … community was sampled during the Micronekton Intercalibration Experiment (MIE-1) in October of 2004 off the south west coast of Oahu. Sampling was conducted during both day and night in the epipelagic (0 – 120 m) and mesopelagic (550 – 650 m) layers, using three micronekton sampling gears …

    ubc Repository record for A novel approach to estimate active carbon flux using the micronekton biomass spectra (opens in a new tab) Download PDF for A novel approach to estimate active carbon flux using the micronekton biomass spectra (opens in a new tab)

  7. Development and testing of an instrument to measure estuarine floc size and settling velocity in situ

    … to 400 mg l-1 INSSEV was used in the 1993 Elbe Intercalibration Experiment where nearly all types of instrumentation for the in situ determination of estuarine floc size and/or settling velocity were deployed over several tidal cycles. From observations in the turbidity maximum of the Tamar …

    plymouth Repository record for Development and testing of an instrument to measure estuarine floc size and settling velocity in situ (opens in a new tab)

  8. DI-TAU TOPOLOGIES AT ATLAS: PREPARATORY STUDIES AND SEARCH FOR HIGGS BOSON DECAYS TO TWO TAU LEPTONS DURING LHC RUN-I

    … decaying tau leptons. Their pseudorapidity intercalibration was cross-checked to 3% on a dataset corresponding to 4.26 fb−1 of pp collisions collected at √s = 7TeV. Validation and preliminary studies for the improvement of the ATLAS standard di-tau mass reconstruction algorithm are also …

    milano Repository record for DI-TAU TOPOLOGIES AT ATLAS: PREPARATORY STUDIES AND SEARCH FOR HIGGS BOSON DECAYS TO TWO TAU LEPTONS DURING LHC RUN-I (opens in a new tab)

  9. Exploring the limits of variational passive microwave retrievals

    … model is applicable to other sensors, pending intercalibration. This retrieval is used to explore the viability of retrieving parameters at the limits of the available information content from a typical microwave imager. Retrieval of warm rain, marginal sea ice, and falling snow are explored …

    colostate Repository record for Exploring the limits of variational passive microwave retrievals (opens in a new tab)

  10. Basis functions for use in direct calibration techniques to determine part-in-hand location

    … is the complexity and lack of robustness of the intercalibration of all the components of the workcell and the part itself.A novel approach to the calibration problem, called Direct Calibration, calibrates the entire assembly system---the robot, the sensors, and the parts to be assembled---in a …

    washington Repository record for Basis functions for use in direct calibration techniques to determine part-in-hand location (opens in a new tab)

  11. The Darkening Arctic from Space: Quantification and Application

    … Imaging SpectroRadiometer (MISR). While the intercalibration experiment confirmed the stability of CERES long-term measurements and accounted for most of the discrepancies in their TOA albedo trends, the remaining differential trends were likely due to the biased MISR albedo retrievals that …

    auckland-ms Repository record for The Darkening Arctic from Space: Quantification and Application (opens in a new tab)

  12. Using uranium- and thorium-series isotopes as tracers for trace-metal inputs to the oceans

    … this method has been proved in the GEOTRACES Ra intercalibration, and shows consistent results with decay counting measurements from other labs. This technique has been applied to water samples in Loch Etive, a Scottish fjord, and in the Cape Basin during the UK-GEOTRACES cruise (GA10E) to …

    oxford Repository record for Using uranium- and thorium-series isotopes as tracers for trace-metal inputs to the oceans (opens in a new tab)

  13. Past Variations of Natural Radiocarbon as Recorded in U.K. Wood

    … in perfect preservation and c) an emphasis on intercalibration and error assessment. The results of radiocarbon analyses of 5 "floating" chronologies, three oak and two pine, are presented. These clearly show that short-term fluctuations in atmospheric radiocarbon do exist, the variations being …

    glasgow Download PDF for Past Variations of Natural Radiocarbon as Recorded in U.K. Wood (opens in a new tab)

  14. A new spatial basis for rivers monitoring and management in Cyprus

    … of the new types with the results of the intercalibration exercise and the fact that the river network is completely new, in comparison to the first RBMP. All these do not bear but small or minimal chances to entail negative effects in practice. Differing views amongst stakeholders about …

    middlesex Download PDF for A new spatial basis for rivers monitoring and management in Cyprus (opens in a new tab)

  15. Investigating the distributions of zinc and cadmium in the subarctic northeast Pacific Ocean

    … between different instrumentations. An intercalibration is necessary to determine if this is an analytical artefact or reflects real oceanic variability.

    uvic Repository record for Investigating the distributions of zinc and cadmium in the subarctic northeast Pacific Ocean (opens in a new tab)

  16. Conodont taxonomy, quantitative biochronology and evolutionary trends during the smithian-spathian interval (early triassic)

    … classic Guryul Ravine section in Kashmir. The intercalibration with the conodont biostratigraphy allows a refined global correlation of the SSB and other important boundaries. Examination of the pelagic conodont faunas shows a significant faunal turnover spanning the SSB with a rapid radiation …

    zurich Restricted access

  17. Design and implementation of the Hybrid Detector for Microdosimetry (HDM): Challenges in readout architecture and experimental results

    … range. This process goes under the name of intercalibration and has a dedicated section in the chapter. Once the signals are intercalibrated, it is necessary to apply a calibration. The new calibration process developed within this work differs from the previously adopted calibration method …

    trento Repository record for Design and implementation of the Hybrid Detector for Microdosimetry (HDM): Challenges in readout architecture and experimental results (opens in a new tab)

  18. Contribución y evolución de las fuentes de material particulado (en PM10) en el puerto de Alicante durante el periodo 2017-2023

    … as a reference. To improve calibration, an intercalibration system for OPC samplers is proposed as an alternative to the current method, which relies solely on infrequent external calibration campaigns. This system aims to enable the use of calibrated hourly time series. The following …

    alicante Repository record for Contribución y evolución de las fuentes de material particulado (en PM10) en el puerto de Alicante durante el periodo 2017-2023 (opens in a new tab)