Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 53 for “"Interdigitated Electrode"”.

  1. Highly sensitive biosensors with interdigitated electrode arrays

    … and may hold a key to point-of-care diagnosis. Interdigitated electrodes (IDE) are often employed as the main sensing platform, and they consist of alternating ‘finger-like’ electrodes that are electrically connected with a width and pitch typically in the range of 5 – 25 m. Through the sensing …

    iastate Repository record for Highly sensitive biosensors with interdigitated electrode arrays (opens in a new tab)

  2. Conducting polymer-based QCM-interdigitated electrode hybrid electronic nose system

    … crystal microbalance (QCM) - conductimetric interdigitated electrode hybrid "second generation" Electronic Nose system. Research objectives covered a number of technical limitations and analytical difficulties existed in the "first generation" Electronic Nose system. A wide variety of work …

    glasgow Download PDF for Conducting polymer-based QCM-interdigitated electrode hybrid electronic nose system (opens in a new tab)

  3. 3D Interdigitated Electrode Array (IDEA) Biosensor For Detection Of Serum Biomarker

    … based on 3-dimensional, comb structured interdigitated electrode arrays was chosen mainly for two reasons. Firstly, this geometry allows the monitoring of both resistivity and dielectric constant of solution, thus making interdigitated electrodes more versatile tools than other kind of …

    portland-state Repository record for 3D Interdigitated Electrode Array (IDEA) Biosensor For Detection Of Serum Biomarker (opens in a new tab)

  4. Fabrication of interdigitated electrode arrays for biosensors by advanced mask aligner lithography

    … amperometric sensor is based on redox cycling at interdigitated electrode arrays (IDA) with gap distances in nano or submicron regime. The focus is on the fabrication of IDAs with conventional mask aligner lithography. For highest sensitivity the crucial dimension is in the nanometer or submicron …

    freiburg-diss Repository record for Fabrication of interdigitated electrode arrays for biosensors by advanced mask aligner lithography (opens in a new tab)

  5. Microfluidic cancer cell isolation system using magnetic nanoparticle hybrids and advanced interdigitated electrode technology

    … and confirming size specifications and detecting electrode rigidity, through scanning electron microscopy. The project is currently being patented due to the uniqueness of the in-vitro cancer therapy concept. AFM confirmed the electrode heights to be approximately 25 nm ± 3 nm, for all three …

    whiterose Download PDF for Microfluidic cancer cell isolation system using magnetic nanoparticle hybrids and advanced interdigitated electrode technology (opens in a new tab)

  6. Transport of polymers and particles microfabricated array devices

    … work in the literature indicates that interdigitated electrode arrays can been used to create such potentials in solution, but no detailed study of particle trajectories has accompanied such experiments. Here, interdigitated electrode array devices were fabricated. Analysis of the …

    oregon Repository record for Transport of polymers and particles microfabricated array devices (opens in a new tab)

  7. Comparison of standard impedance spectroscopy response to aqueous metal ions using plain vs. surface derivatized gold interdigitated electrodes

    … with CS2 to anchor on the gold surface of an interdigitated electrode (IDE) through a dithiocarbamate linkage, resulting in significant changes in impedance response in the presence of Cu2+ solutions. However, questions regarding the stability of the primary amine-based dithiocarbamate …

    emich Repository record for Comparison of standard impedance spectroscopy response to aqueous metal ions using plain vs. surface derivatized gold interdigitated electrodes (opens in a new tab)

  8. Effects of Alternating Current Electrical Stimulation on the Cellular Chemistry and Proliferation of C2C12 Muscle Cells

    … the condition of AC electrical stimulation using interdigitated electrode arrays. This research was conducted by applying electrical signals for up to 24 hours to C2C12 muscle cells. After 24 hours, the electrical impedance, cell morphology, proliferation and viability were recorded. The results …

    ndsu Repository record for Effects of Alternating Current Electrical Stimulation on the Cellular Chemistry and Proliferation of C2C12 Muscle Cells (opens in a new tab)

  9. MINIATURIZED NEUTRON RADIATION DETECTOR USING BORON-NITRIDE AND MULTI-WALLED CARBON NANOTUBES

    … and multi-walled carbon nanotubes with an interdigitated electrode design printed with conducting ink can be used to detect thermal neutron radiation. This thesis explores how the initial resistance of the boron-nitride nanotube and multi-walled carbon nanotube mixture, which forms the …

    nps Repository record for MINIATURIZED NEUTRON RADIATION DETECTOR USING BORON-NITRIDE AND MULTI-WALLED CARBON NANOTUBES (opens in a new tab)

  10. Investigation of synthetic methods for preparation of 2<sup>o</sup>-amino derivatives of 5-amino- 1, 10-phenanthroline: Applications to Cu<sup>+2</sup> based impedance sensors

    … application as self-assembled monolayers on gold interdigitated electrode array chips in standard impedance and impedance resonance-based Cu2+ sensors. Potential applications include monitoring Cu2+ leaching from anti-fouling coatings on ship hulls. The importance of the planned secondary alkyl …

    emich Repository record for Investigation of synthetic methods for preparation of 2<sup>o</sup>-amino derivatives of 5-amino- 1, 10-phenanthroline: Applications to Cu<sup>+2</sup> based impedance sensors (opens in a new tab)

  11. Σχεδίαση και ανάπτυξη βιοαισθητήρα για την ταχεία ανίχνευση του SARS-CoV-2

    … of the virus, the enzyme ACE2, on the surface of interdigitated electrode capacitors. The results of the biosensor measurements are correlated with the real-time PCR results for the same samples.Then, after the sensor has been verified to function properly, the sensor is integrated into a …

    greece Repository record for Σχεδίαση και ανάπτυξη βιοαισθητήρα για την ταχεία ανίχνευση του SARS-CoV-2 (opens in a new tab)

  12. The Development of an Integrated Microengineered Ion Sensor (Inion) for Cesium

    … the membrane that is formed on top of a planar interdigitated electrode, thus allowing the monitoring of the membrane conductivity. Characterisation of the planar interdigitated electrode was undertaken using numerous techniques. This that that there was considerable inter-diffusion of the …

    cent-lancashire Download PDF for The Development of an Integrated Microengineered Ion Sensor (Inion) for Cesium (opens in a new tab)

  13. Metaloorganinio perovskito fotodetektorių formavimas ant periodiškai išdėstytų elektrodų matricos ir jų optoelektrinių savybių tyrimas /

    … photoconductive photodetectors made on interdigitated combs of electrodes of different metals were presented. The role of the oxide layer in the performance of planar perovskite photodetectors formed on interdigitated metal electrodes is demonstrated. The oxide layer enhances the …

    vilnius Repository record for Metaloorganinio perovskito fotodetektorių formavimas ant periodiškai išdėstytų elektrodų matricos ir jų optoelektrinių savybių tyrimas / (opens in a new tab)

  14. Bactesign Biosystems Technologies for In Vitro Bacterial Models

    … printed substrates, for enhanced resolution of interdigitated electrode (IDE) characteristics. Using our IDE method, we successfully recorded four parameters of bacterial biofilm growth, separating bacterial species at the 9.77 kHz frequency point at the 2- and 8-hour time points. When testing …

    ucf Repository record for Bactesign Biosystems Technologies for In Vitro Bacterial Models (opens in a new tab)

  15. Redox cycling for an in-situ enzyme labeled immunoassay on interdigitated array electrodes

    … immunoassays by coupling redox cycling at interdigitated electrode arrays (IDA) with the enzyme label b-galactosidase. Coplanar and comb IDA electrodes with a 2.4 mm gap were fabricated and their redox cycling currents were measured. ANSYS was used to model steady state currents for …

    gatech Repository record for Redox cycling for an in-situ enzyme labeled immunoassay on interdigitated array electrodes (opens in a new tab)

  16. Measuring Acid Generation Kinetics in Photoresist Films via Capacitance Techniques

    … that utilizes capacitance measurements from interdigitated electrodes. In this technique, a chemically amplified photoresist is first coated onto the interdigitated electrode sensors. Then, capacitance measurements are recorded from the sensor as the photoresist is exposed to UV radiation. As …

    gatech Repository record for Measuring Acid Generation Kinetics in Photoresist Films via Capacitance Techniques (opens in a new tab)

  17. Pulsed field electroflotation for harvesting microalgae

    … 23 factorial tests were performed on a coplanar interdigitated electrode array. The waveform variables reviewed included applied potential, duty cycle, and frequency. The smallest mean bubble diameter (30.1 μm) occurred at 3V, 20%, 25 Hz. The smallest median bubble diameter (25.0 μm) occurred at …

    hawaii Repository record for Pulsed field electroflotation for harvesting microalgae (opens in a new tab)

  18. Application of impedance spectroscopy to the study of dithiocarbamate species on Au surfaces: Effects of aqueous Cu²⁺ and Mg²⁺ ions

    … ligands were formed on the Au surface of an interdigitated electrode (IDE) array by reaction of amines with CS2 in H2O/CH3OH solutions. Impedance spectroscopy was used to probe for the presence of each SAM as they were individually applied to the surface of the IDE by examining differences in …

    emich Repository record for Application of impedance spectroscopy to the study of dithiocarbamate species on Au surfaces: Effects of aqueous Cu²⁺ and Mg²⁺ ions (opens in a new tab)

  19. Development of a MEMS-Based Resonant and Impedimetric Multivariate Sensor for the Speciation And Quantification of Volatile Organic Compounds

    … microcantilever in combination with a collocated interdigitated electrode (IDE) structure underneath a single polymeric sensing film to provide both gravimetric and impedimetric analysis of gaseous analytes in the environment. Multivariate analysis techniques including dispersion analysis and …

    gatech Repository record for Development of a MEMS-Based Resonant and Impedimetric Multivariate Sensor for the Speciation And Quantification of Volatile Organic Compounds (opens in a new tab)

  20. Synthesis and characterization of conducting polymer nanostructures and their application in sensors

    … nanocomposites in the active area of an interdigitated electrode array. Polyaniline nanofiber sensors can be fabricated by irradiating an aqueous precursor solution containing aniline, HCl, a metal salt, and ammonium persulfate (APS) with a high pressure Hg lamp. The sensors are ready for …

    must-thes Repository record for Synthesis and characterization of conducting polymer nanostructures and their application in sensors (opens in a new tab)

Page 1 of 3