Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 13 of 13 for “"Interelectrode distance"”

  1. The role of interelectrode distance in electrical discharge machining,

    Thesis (Sc. D.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 1969.

    mit Repository record for The role of interelectrode distance in electrical discharge machining, (opens in a new tab)

  2. Fabrication of dissimilar metal electrodes with nanometer interelectrode distance suitable for the electrical characterization of molecular-scale electronic devices

    … dissimilar metal electrodes with a minimum interelectrode distance of less than 6 nm using electron beam lithography and liftoff pattern transfer. Electrode structures employing pairs of Au or AuPd electrodes and a dissimilar metal electrode were fabricated in three different patterns. 300 …

    ut-knoxville Repository record for Fabrication of dissimilar metal electrodes with nanometer interelectrode distance suitable for the electrical characterization of molecular-scale electronic devices (opens in a new tab)

  3. Neural Adaptation and the Effect of Interelectrode Spacing on Epidural Electrocorticography for Brain-Computer Interfaces

    … significant performance in 10 days or less. Interelectrode distance between control electrodes was also tested for three different distances. 15 and 9 mm spacing resulted in equivalent performance while 3 mm saw a moderate but significant degradation in performance. Finally, post hoc analysis …

    wustl Repository record for Neural Adaptation and the Effect of Interelectrode Spacing on Epidural Electrocorticography for Brain-Computer Interfaces (opens in a new tab)

  4. The effect of muscle contractility on surface EMG /

    … using X-rays to identify the relative change in distance between two intramuscular wire electrodes we found the change in TA muscle length for this study to be 15% over the 60$ sp circ$ of ankle rotation. Second, to test for synergist contamination we used fine wire electrodes in the Extensor …

    mcgill Repository record for The effect of muscle contractility on surface EMG / (opens in a new tab)

  5. High frequency glow discharge with internal electrodes

    … mean free path of the electron is equal to the interelectrode distance. (8) The amplitudes of oscillation of the free electron for wavelengths which give line intensity minima and maxima are multiples of the electronic mean free path. (9) The impurities which are commonly observed in this type …

    iastate Repository record for High frequency glow discharge with internal electrodes (opens in a new tab)

  6. Effects of chest wall configuration and electrode positioning on human diaphragmatic EMG

    … is that an increase in the muscle-to-electrode distance (MEdist) acts as a low-pass filter, filtering out the high frequency components of the EMG power spectrum (the MEdist filter). Due to the numerous factors which can influence the EMGdi, control of signal quality is also of utmost …

    mcgill Repository record for Effects of chest wall configuration and electrode positioning on human diaphragmatic EMG (opens in a new tab)

  7. Critical analysis of techniques for normalising electromyographic data : from laboratory to clinical research

    … area, orientation, shape of electrodes and the distance between electrodes (interelectrode distance). In order to measure biological variation in the EMG signal, which is important in studies where surface EMG is used to gain understanding of physiological regulation, it is important to minimise …

    cape-town Repository record for Critical analysis of techniques for normalising electromyographic data : from laboratory to clinical research (opens in a new tab)

  8. Investigation of Neural Interfaces and Stimulation Methods for Enhancing Selective Cervical Vagus Nerve Stimulation

    … electrode edge length on the side of the anode, interelectrode distance, and the use of a secondary anode placed to counteract the virtual cathode. Overall, this thesis provides a series of recommendations for novel technologies for vagus nerve stimulation through the use of new stimulation …

    toronto-retro Repository record for Investigation of Neural Interfaces and Stimulation Methods for Enhancing Selective Cervical Vagus Nerve Stimulation (opens in a new tab)

  9. Effects of isometric elbow flexion on electromyographic spike analysis

    … RI) placed in a bipolar configuration, with an interelectrode distance (lED) of 2cm distal to the motor point. Data analysis was performed on a I second window of data in the middle of the 5-second contraction. The results indicated that all spike shape measures exhibited significant (p < 0.01) …

    brock Repository record for Effects of isometric elbow flexion on electromyographic spike analysis (opens in a new tab)

  10. Studies on the Elemental Measurement of Aerosols Using Microplasma Spectroscopy

    … spectroscopic means, and their dependences on interelectrode distance, delay time and pulse energy are presented.

    ohiolink Repository record for Studies on the Elemental Measurement of Aerosols Using Microplasma Spectroscopy (opens in a new tab)

  11. High-Quality Microcrystalline Silicon for Efficient Thin-Film Solar Cells : Insights into Plasma and Material Properties

    … and powder formation. The use of a reduced interelectrode distance is demonstrated to allow for the growth of μc-Si:H with significantly improved bulk material quality at higher growth rates. Plasma simulations performed in collaboration with the University of Patras are presented and …

    epfl Repository record for High-Quality Microcrystalline Silicon for Efficient Thin-Film Solar Cells : Insights into Plasma and Material Properties (opens in a new tab)

  12. Mechanistic, interfacial and modeling studies of electro-precipitation during electrochemical advanced oxidation process in a thin-film reactor : case study with reclaimed municipal wastewater

    … que la densité de courant appliquée (japp), la distance interélectrode (delec), la matrice de l'effluent à traiter et le matériau de la cathode. Des modèles théoriques ont été proposés pour accompagner les résultats expérimentaux acquis. D’un point de vue pratique, l'objectif a été d'établir les …

    star-france Repository record for Mechanistic, interfacial and modeling studies of electro-precipitation during electrochemical advanced oxidation process in a thin-film reactor : case study with reclaimed municipal wastewater (opens in a new tab)