Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 19 of 19 for “"Interface pressures"”.

  1. Biomechanics of Patient Handling Slings Associated with Spinal Cord Injuries

    … Veterans Hospital. High resolution pressure interface mapping was utilized to directly measure the interface pressures between the patient and sling interface. Overall results provide relevant feedback on the systems used and to suggest a particular type of sling that might reduce and …

    usf Repository record for Biomechanics of Patient Handling Slings Associated with Spinal Cord Injuries (opens in a new tab)

  2. The effect of transverse rotation and longitudinal translation between prosthetic components during the gait of unilateral trans-tibial amputees

    … are transmitted across the residual limb socket interface. These loads and associated gait patterns can be altered by introducing compliant elements into the prosthesis. However, previous studies have failed to adequately describe the effects that components with such compliances have on amputee …

    salford Download PDF for The effect of transverse rotation and longitudinal translation between prosthetic components during the gait of unilateral trans-tibial amputees (opens in a new tab)

  3. Evaluation of a novel thoracic support for police officers during prolonged simulated driving exposures

    … equipment worn by officers creates a unique interface between the occupant and the car seat. Purpose: To evaluate a novel thoracic support that was designed to address the unique seated working demands of mobile police officers. Methods: Fourteen participants: 7 male (21.3 (1.9) years, 1.71 …

    waterloo Repository record for Evaluation of a novel thoracic support for police officers during prolonged simulated driving exposures (opens in a new tab)

  4. A bioengineering investigation of the design and fit of cervical collars

    … focusing only on range-of-motion restriction and interface pressures. Improved collar design and fitting practices could help prevent the costly consequences of pressure ulcers. <br/>This research aimed to investigate cervical collar design and fit using state-of-the-art methods for monitoring …

    soton Repository record for A bioengineering investigation of the design and fit of cervical collars (opens in a new tab) Download PDF for A bioengineering investigation of the design and fit of cervical collars (opens in a new tab)

  5. Data technologies for lower limb orthosis design and assessment

    … with a more compliant material caused lower peak interface pressures and pressure gradients. Greater elevations in temperature and humidity occurred where the AFOs were more encompassing. Cotton socks controlled temperature better but humidity was higher than with bamboo socks. Simplified forefoot …

    soton Repository record for Data technologies for lower limb orthosis design and assessment (opens in a new tab) Download PDF for Data technologies for lower limb orthosis design and assessment (opens in a new tab)

  6. An experimental investigation of a radial face seal

    … which will allow a complete description of the interface fluid film of a radial face seal. The equipment necessary for the monitoring of the vertical load, torque, temperature, supply pressure, interface pressure, interface clearance, and rotational speed has been integrated into a workable …

    ut-knoxville Repository record for An experimental investigation of a radial face seal (opens in a new tab)

  7. Malhas de compressão: caracterização mecânica e análise de viabilidade aplicada ao vestuário de compressão

    … analysis using optical microscopy, and interface pressure measurements using an adapted experimental system based on a pneumatic chamber and a clinical sphygmomanometer. The obtained data were analyzed using descriptive statistics. The results indicated that the proportion of elastane …

    brazil-ufrn Repository record for Malhas de compressão: caracterização mecânica e análise de viabilidade aplicada ao vestuário de compressão (opens in a new tab)

  8. Ambulatory Sub-Bandage Pressure Assessment: Background and implementation

    … and monitoring of ambulatory sub-bandage interface pressures, on healthy volunteers and patients, as the basis for more in-depth future studies.<br/><br/>The projected study required a literature review concerning the socio-economic aspects, aetiology and healing methods (focusing on …

    southwales Repository record for Ambulatory Sub-Bandage Pressure Assessment: Background and implementation (opens in a new tab) Download PDF for Ambulatory Sub-Bandage Pressure Assessment: Background and implementation (opens in a new tab)

  9. Experimental Evaluation of Knee Exoskeleton Interface Mechanisms

    … and on a human participant. During testing, interface pressures between the limb and the cuff, as well as limb and exoskeleton positions, were measured to compare different configurations. The results support adding passive translation along the axis of the shank as well as in the transverse …

    ottawa-retro Repository record for Experimental Evaluation of Knee Exoskeleton Interface Mechanisms (opens in a new tab)

  10. An experimental and analytical investigation of a radial face seal

    <p>A complete description concerning the interface region of a parallel radial face seal has been conducted both experimentally and analytically. Analytical predictions stem from a F&#xF8;RTRAN IV computer program designed such that density and viscosity variation with temperature can be simulated. …

    ut-knoxville Repository record for An experimental and analytical investigation of a radial face seal (opens in a new tab)

  11. Pressure distribution at the stump socket interface in trans-tibial amputees

    … the pressure distribution at the stump socket interface, the fabrication of the socket still relies mostly on the skill of the prosthetist. In a patellar tendon bearing prosthesis, load is mainly taken by the patellar tendon bar.This study was aimed at investigating the stump/socket interface …

    strathclyde Repository record for Pressure distribution at the stump socket interface in trans-tibial amputees (opens in a new tab)

  12. Development of a Tool for Pressure Ulcer Risk Assessment and Preventive Interventions in Ancillary Services Patients

    … units where extrinsic risk factors such as high interface pressures on procedure tables and friction and shear from positioning and transport can greatly magnify the effect of patient-specific intrinsic risk factors which might not otherwise put these patients at high risk on an inpatient unit. …

    usf Repository record for Development of a Tool for Pressure Ulcer Risk Assessment and Preventive Interventions in Ancillary Services Patients (opens in a new tab)

  13. Determination of thermal contact resistance between metals using a pulse technique

    … the directional effect exists at relatively low interface pressures. Thermal contact resistance decreased approximately 40 percent for aluminum 2024-TJ and aluminum 6061-T6 specimens. Aluminum 7075-T6 specimens decreased approximately 75 percent in thermal contact resistance over the interface …

    must-thes Repository record for Determination of thermal contact resistance between metals using a pulse technique (opens in a new tab)

  14. Design and Testing of a Traction/Distraction Knee Brace

    … the traction load to wearer discomfort and interface force. The first objective was met through prospective analysis and iterative design. A planar finite element (FE) model of the lower leg was used to analyse the effect of knee brace coverage. It was observed that increasing the coverage …

    sask Repository record for Design and Testing of a Traction/Distraction Knee Brace (opens in a new tab)

  15. A Benchtop Analysis of Pressure Offloading Associated With Custom Socket Inlays in Transtibial Prostheses

    … inlays. Static loads were applied, and socket interface pressures were measured. Inlays were created, which fit into the indentions made in the socket of a lower limb prosthesis. The blanks had a smooth, solid exterior surface, while the pressure-offloading meta-material inlays had a triangular …

    clemson Repository record for A Benchtop Analysis of Pressure Offloading Associated With Custom Socket Inlays in Transtibial Prostheses (opens in a new tab)

  16. Investigating the mechanisms of soft tissue damage at the residual limb-socket interface

    … below knee amputation form a critical loaded interface with the prosthetic limb. In the early stages of rehabilitation, residual limb tissues have not been conditioned to support loading and are vulnerable to damage. This impacts upon quality of life and can lead to rejection of the …

    soton Download PDF for Investigating the mechanisms of soft tissue damage at the residual limb-socket interface (opens in a new tab)

  17. An integrated human factors approach to design and evaluation of the driver workspace and interface: Driver perceptions, behaviors, and objective measures

    An ergonomic driver workspace and interface design is essential to ensure a healthier and comfortable driving experience in terms of driver perceptions, postures, and interface pressures. Developing more effective methods for driver-side interior design and evaluation, hence, requires thorough …

    vt Repository record for An integrated human factors approach to design and evaluation of the driver workspace and interface: Driver perceptions, behaviors, and objective measures (opens in a new tab)