Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 8 of 8 for “"Interior connections"”.
-
Punching shear behaviour of GFRP-RC slab-column interior connections with high strength concrete and shear reinforcement
… full-scale reinforced concrete (RC) slab-column interior connections were constructed and tested to failure. Two variables were investigated; the flexural reinforcement ratio when high strength concrete (HSC) is used and the type of GFRP shear reinforcement (headed studs and corrugated bars) when …
-
Seismic resistance of fiber-reinforced slab-column connections
Three interior and three exterior fiber reinforced slab-column connections were subjected to gravity loads and then tested under lateral load simulating earthquake forces. Test results were compared to previous tests on non-fiber slab-column connections. Addition of steel fiber to the concrete …
-
Seismic response of connections in indeterminate flat-slab subassemblies
… typically initiates at the slab-column connections in the form of a punching failure. This investigation was carried out to evaluate the adequacy of current procedures for the design of slab-column connections. The variables studied included the intensity of gravity loading, slab shear …
-
Seismic resistance of slab-column connections in non-ductile flat-plate buildings
… Each specimen had two exterior and one interior connections. The variables included the presence of spandrel beam, magnitude of gravity load, and reinforcing arrangement. The behavior of entire subassemblies and the individual connections under the cyclic loading was studied in terms of …
-
Strength of edge column-slab connections of post-tensioned concrete flat plates.
The strength and behavior of edge column-slab connections of two way unbonded post-tensioned flat slab under uniformly distributed load were investigated. A square flat slab, two bays in each direction was constructed. The span of each bay was 3.2 m (10.5 ft) and the slab 89 mm (3.5 in) thick. …
-
Evaluation, Modeling, and Retrofit of Flat-Slab Buildings subjected to Seismic Loading
… resistance. Punching failure at slab-column connections in non-ductile flat-slab buildings during earthquakes can trigger progressive collapse of floor slabs. Based on the test results of a large number of interior and exterior connections, a methodology is developed to predict shear and …
-
An Analytical Study on the Behavior of Reinforced Concrete Interior Beam-Column Joints
… global performance of both one-way and two-way interior BC joints. Such simulations can be used to study the flexural-shear-bond interaction, the failure modes, and sensitivity of various parameters of structural elements. Most of the existing analytical approaches for interior BC joints have …
-
Effect of Unbalanced Moment on Punching Shear Strength of Slab-Column Joints
… of reinforced concrete flat plate slab-column connections subjected to unbalanced moments varies greatly between national design codes. Specific to Canada and the United States (U.S.), assumptions relating to the distribution of unbalanced moments between shear and flexure stresses were …