Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 6 of 6 for “"Interior slab-column connection"”

  1. Punching failure and compressive membrane action in reinforced concrete slabs

    … membrane action in reinforced concrete slabs provides a basis for the development of a more realistic design approach for continuous slabs subjected to concentrated loadings.The results of an extensive series of tests on one quarter scale models of the interior slab—column connection in …

    qu-belfast Repository record for Punching failure and compressive membrane action in reinforced concrete slabs (opens in a new tab)

  2. Nonlinear Finite Element Analysis of Punching Shear of Reinforced Concrete Slab-Column Connections

    … provisions for the design of reinforced concrete slabs are based on empirical and mostly statistical formulations derived from the tests. The available testing database consists of different types of slabs and in some cases it is limited due to the extensive cost and time that a punching shear …

    waterloo Repository record for Nonlinear Finite Element Analysis of Punching Shear of Reinforced Concrete Slab-Column Connections (opens in a new tab)

  3. Nonlinear finite element analysis of punching shear of reinforced concrete slab-column connections

    … provisions for the design of reinforced concrete slabs are based on empirical and mostly statistical formulations derived from the tests. The available testing database consists of different types of slabs and in some cases it is limited due to the extensive cost and time that a punching shear …

    greece Repository record for Nonlinear finite element analysis of punching shear of reinforced concrete slab-column connections (opens in a new tab)

  4. Nonlinear Finite Element Analysis of Punching Shear of Reinforced Concrete Slabs Supported on Rectangular Columns

    … for the punching shear of reinforced concrete slabs supported on rectangular columns vary greatly and are primarily based on empirical results. Additionally, the existing database for slabs supported on rectangular columns is quite small compared to the empirical database for reinforced …

    waterloo Repository record for Nonlinear Finite Element Analysis of Punching Shear of Reinforced Concrete Slabs Supported on Rectangular Columns (opens in a new tab)

  5. Nonlinear Finite Element Analysis of Reinforced Concrete Slab-Column Connections with Headed Stud/Bolt Shear Reinforcement Subjected to Punching Shear

    … punching behaviour of reinforced concrete flat slabs supported on columns with headed stud/bolt shear reinforcement, there are still many parameters which have not been adequately studied in the laboratory due to cost or time constraints. As a result much of the current code provisions for …

    waterloo Repository record for Nonlinear Finite Element Analysis of Reinforced Concrete Slab-Column Connections with Headed Stud/Bolt Shear Reinforcement Subjected to Punching Shear (opens in a new tab)

  6. Finite Element Analysis of Reinforced Concrete Slab-Column Connections for Seismic Performance Investigation

    In reinforced concrete (RC) flat plate systems, slab-column connections are critical components, susceptible to brittle punching shear failure under seismic actions. The current code provisions for the design of RC flat slabs are generally based on empirical formulations derived from tests, thus, …

    queens Repository record for Finite Element Analysis of Reinforced Concrete Slab-Column Connections for Seismic Performance Investigation (opens in a new tab)