Optimization of intermittent aeration for increased nitrogen removal efficiency and improved settling
… both increased volume (capital costs) and aeration energy demand (operating costs). As an alternative, HRSD is pilot testing an A/B process; a two-sludge system comprised of a carbon removal stage followed by a nitrogen removal stage. The very high rate, low dissolved oxygen (DO) A-stage …
-
The effect of sludge age and aerobic sludge mass fraction on low F/M filament bulking in intermittent aeration nitrogen removal systems
… The experimental set-up consisted of two intermittently. aerated anoxic-aerobic (20 minute cycles, peak DO 2 to 2,5 mgO/l), single reactor completely mixed continuously fed systems. The experimental investigation was chronologically divided into 3 phases and examined the effect of the …
-
Integrating an Intermittent Aerator for a Swine Wastewater Treatment System
Integrating an intermittent aeration for the treatment of combined dilute and anaerobic digested swine wastewater in a field swine wastewater treatment system was investigated. Four operations models in term of ratio of aeration to no-aeration of 60:36, 5:1, 4:2 and 3:3 hour were evaluated. At the …
-
Development of a Kinetically Engineered Microbial Community for Nitrite Shunt as a B-Stage Process Using Different Aeration Strategies
… effluent, its fractionation, and the applied aeration strategy. At carbon to nitrogen (C:N) ratio as low as 6.0, ammonia, COD and total inorganic nitrogen (TIN) removal efficiencies of 99.2±0.7, 94.0±0.1 and 93.2±1.6% were successfully achieved under continuous low DO aeration strategy. …
-
Simultaneous Removal of Carbon and Nitrogen by Using a Single Bioreactor for Land Limited Application
… reactor was operated with alternate schedules of intermittent aeration. Two different sizes of carriers (10 * 10 * 10 mm3 and 20 * 20 * 20 mm3) were studied. The medium carrier (10 * 10 * 10 mm3) system presents higher nitrogen removal and COD removal compared to the large carrier system. The …
-
Energy Conservation By Intermittently Recirculating and Aerating an Aquaponics System with an Airlift
An airlift device providing aeration and circulation was designed to reduce electrical power requirements for aquaponics by eliminating the need for a water pump. The airlift performed better than predicted and achieved water flow rates of 10 L/min at 25 °C, in comparison to the theoretical design …
-
Pilot Scale Application of Partial Nitritation Anammox and Partial Denitrification Anammox Treating Industrial Fertilizer Waste with High Ammonia and Nitrate
… study was configured as a single stage MBBR with intermittent aeration with the goal of optimizing operability and a scalable process for full scale design. Analysis of the industrial wastewater showed variation in the AvN levels, which was a challenge for making the phase I configuration feasible …
-
Conservation of Nitrogen via Nitrification and Chemical Phosphorus Removal for Liquid Dairy Manure
… of this study were to (1) determine an intermittent aeration strategy that could be used to conserve nitrogen (N) via nitrification in dairy manure, (2) determine the effect of recycled flush water on the bio-availability of N during nitrification, and (3) determine effective and …
-
Machine Learning Methods for Wastewater Treatment Plants
… probe readings are particularly crucial for intermittent aeration controllers, which rely on real-time measurements of ammonia and oxygen in biological tanks. These data are an important resource for developing artificial intelligence algorithms that can identify process or sensor anomalies. …
-
Data-driven control design of wastewater treatment systems
… the modelling of the activated sludge for an intermittent aeration process. The control design part of the thesis employs a two level hierarchical control approach. The low level control is usually a proportional integral derivative controller (PID) type. This thesis presents the development …
-
Development of Low Energy Aeration System For Enhanced Biological Phosphorus Removal (EBPR)
… major phases: anaerobic phase and aerobic phase. Aeration costs in the aerobic phase are relatively high in EBPR system. Finding a new approach for decreasing the amount of aeration needed for EBPR systems recently has grown in importance. Most of the research done on EBPR process was focusing on …
-
Biological Nitrogen and Phosphorus Removal From Wastewater Under Low Dissolved Oxygen (LDO) Conditions
… (A/O/A) systems, continuous and intermittent aeration regimes, and air OFF/air ON periods ratios for efficient nitrogen and phosphorus removal. Two continuous aeration systems were implemented: The first aimed to carry out a simultaneous nitrification and denitrification (SNdN) …
-
Avaliação de sistema RBS de dois estágios com aeração intermitente alimentado por energia solar em região tropical
… system submitted to long non-aerated periods (intermittent aeration) was studied to evaluate its performance in removing MO, nitrogen and phosphorus from domestic wastewater. The influence of aeration time on battery life was also evaluated. The system was subjected to daily inflows of 3, 4.5 …
-
Aeration of Stockade Lake, South Dakota
Intermittent aeration of Stockade Lake (2,470 acre feet) during the summers of 1967 and 1968 temporarily altered the thermal profile and phytoplankton density. Continual aeration for 48 hours in the deepest portion of this eutrophic lake produced epilmnetic cooling, hypolimnetic warming and …
-
Hydraulic design of IEA wastewater treatment plant decant systems
… for sludge carry-over during decant from an intermittent aeration tank. Several mechanisms were identified which may cause sludge carry-over. An 'early failure' mode may occur during the transient phase at the start of decant. This failure mode can be avoided by gradually increasing the rate …
-
Oxidation-reduction potential and organic carbon sources as two control parameters for simultaneous nitrification and denitrification in biological nutrient removal processes
… (P) removal from domestic sewage, in a two-stage intermittent aeration (IA) process, under conditions favorable to simultaneous nitrification and denitrification (SND). It was demonstrated in this study that, under the above operating conditions, the twostage process achieved levels of N, P and C …
-
The effect of fully anoxic conditions and frequency of exposure to anoxic and aerobic conditions on the growth of low F/M filaments in nitrogen remova
… concentrations during the anoxic phase of an intermittent aeration cycle on low F/M filament growth in continuously fed completely mixed single reactor systems receiving a synthetic sewage feed; (2) the effect of fully anoxic conditions on low F/M filament growth in continuously fed completely …
-
Metabolic effects of oxygen-transfer in microbial culture
… and monitor some possible effects of 'cyclic aeration', a phenomenon experienced by microorganisms in most industrial fermentations. Batch and continuous cultures were carried out both aerobically and anaerobically, using a synthetic glycerol-salts medium. 'Cyclic aeration' was simulated by …
-
Biological nutrient removal in bench-scale membrane bioreactor and full-scale sequencing batch reactor under various configurations and conditions
… of anaerobic, anoxic, and oxic sequences with intermittent aeration into the cycles of a full-scale sequencing batch reactor system (SBR) resulted in improvement in biological nutrient removal for the treatment of municipal wastewater and wastewater from a salad dressing plant. The two modified …
-
Preventive control of ammonia and odor emissions during the active phase of poultry manure composting
… dosages above 2.5%. This study reaffirmed that aeration is the most influential factor to odor emission. An optimal airflow rate for odor control would be 0.6 L/min.kg dry matter with an intermittent aeration system. Quantitative relationships between odor emission and key operational parameters …