Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 41 for “"Internal calibration"”.

  1. Design, fabrication, and demonstration of low-mass, low-power, small-volume, direct detection millimeter-wave radiometers at 92 and 130 GHz

    … testing of two direct detection radiometers with internal calibration at center frequencies of 92 and 130 GHz. Component design, testing and integration of the radiometers using multi-chip modules are discussed. The performance of these radiometers is characterized, including noise figure, …

    colostate Repository record for Design, fabrication, and demonstration of low-mass, low-power, small-volume, direct detection millimeter-wave radiometers at 92 and 130 GHz (opens in a new tab)

  2. Investigating musculoskeletal changes in critically ill patients with computed tomography (CT) imaging

    … risk. First, I adapted and validated a CT internal calibration method for reliable muscle density analysis. I then applied this internal calibration method to clinically acquired CT images of critical care patients, and I found that critical care patients undergo a significant reduction in …

    calgary Repository record for Investigating musculoskeletal changes in critically ill patients with computed tomography (CT) imaging (opens in a new tab)

  3. Radiometric Stability Analysis of Landsat- I through -5 MSS Sensors

    … MSS sensors in the past were calibrated based on internal calibration data. Hence, it is important to study the stability of the internal calibration system to ensure that the detectors were calibrated correctly. This stability analysis was done using three different time intervals ranging from a …

    sdstate Repository record for Radiometric Stability Analysis of Landsat- I through -5 MSS Sensors (opens in a new tab)

  4. The Rayleigh ratio measurement for SNO+ liquid scintillator and background studies of the internal ropes

    … was tested. The _ and backgrounds, due to the internal calibration ropes situated in the scintillator volume, were studied using the SNO+ Monte Carlo Package. Also, the amount of 210Pb originating from the internal calibration ropes due to the intrinsic contamination of 238U, Rn emanation and …

    queens Repository record for The Rayleigh ratio measurement for SNO+ liquid scintillator and background studies of the internal ropes (opens in a new tab)

  5. Study of Output and Behavior of LLMs Using Confidence Framing in Prompt Engineering

    … the impact of confidence framing on behavioral calibration remains underexplored. This study investigates the ways in which psychological framing, utilizing techniques such as capability praise, role amplification, and doubt induction, affects linguistic tone, objective accuracy, and internal …

    embry-riddle Repository record for Study of Output and Behavior of LLMs Using Confidence Framing in Prompt Engineering (opens in a new tab)

  6. Development of a prognostication model for breast cancer in British Columbia

    … concordance by about 0.006. However, while the internal calibration was satisfactory, as it was close to 1, the discrimination of the models was unsatisfactory, with concordances around 0.63. Compared to several models in the literature, our model performance was similar, with concordances near …

    ubc Repository record for Development of a prognostication model for breast cancer in British Columbia (opens in a new tab) Download PDF for Development of a prognostication model for breast cancer in British Columbia (opens in a new tab)

  7. The factors and protocols that influence, accuracy, precision and uncertainty of accurate mass measurements by FT-ICR ms to validate the assignment of elemental composition

    … errors (MME) are usually obtained using internal calibration, as the sample and calibrant ions inside the ICR cell experience the same conditions. However, internal calibration requires calibrant ions to be selected according to the mass of the sample ion, which requires operator …

    soton Download PDF for The factors and protocols that influence, accuracy, precision and uncertainty of accurate mass measurements by FT-ICR ms to validate the assignment of elemental composition (opens in a new tab)

  8. Development and fabrication of low-mass, low-power, internally-calibrated, MMIC-based millimeter-wave radiometers at 92 and 166 GHz

    … fabrication, and testing of two millimeter-wave internally calibrated MMIC based radiometers operating at 92 and 166 GHz. These laboratory prototype radiometers are intended to increase the technological maturity of the radiometer components and reduce the risk, development time and cost of …

    colostate Repository record for Development and fabrication of low-mass, low-power, internally-calibrated, MMIC-based millimeter-wave radiometers at 92 and 166 GHz (opens in a new tab)

  9. Argos: Practical Base Stations for Large-scale Beamforming

    … beamforming technique, as well as an internal calibration procedure to enable implicit beamforming across large arrays. We implement a prototype with 64 antennas, and demonstrate that it can achieve up to 6.7 fold capacity gains while using a mere 1/64th the transmission power.

    rice Repository record for Argos: Practical Base Stations for Large-scale Beamforming (opens in a new tab)

  10. Nuclear Structure Study of Cd-110 through Internal Conversion Electrons

    … result from intruder bands. The study through internal conversion electrons is important to investigate intruder structures in Cd-110, using the enhanced E0 transitions between intruder states and spherical phonon states as a signature. The nuclear structure of Cd-110 has been studied with …

    guelph Repository record for Nuclear Structure Study of Cd-110 through Internal Conversion Electrons (opens in a new tab)

  11. Validating Internal Density Calibration in The Proximal Humerus to Estimate Bone Stiffness Using Finite Element Analysis for Stemless Shoulder Arthroplasty

    … component. Traditionally, in-scan phantom calibration determines volumetric bone mineral density (vBMD) from greyscale intensity in computed tomography (CT) images, but this method is rarely used in clinical practice due to limited time and resources. As a result, alternative density …

    waterloo Repository record for Validating Internal Density Calibration in The Proximal Humerus to Estimate Bone Stiffness Using Finite Element Analysis for Stemless Shoulder Arthroplasty (opens in a new tab)

  12. Analysis of Oligosaccharides via Ion Mobility-Mass Spectrometry

    … between experiments. We therefore introduced an internal calibration method for the conversion of retention times into universal glucose units (GU) and drift times into collisional cross-sections (CCS). It was shown that the internal calibration approach enabled a faster, more accurate analysis …

    fu-berlin Repository record for Analysis of Oligosaccharides via Ion Mobility-Mass Spectrometry (opens in a new tab)

  13. Reduced Evapotranspiration From Leaf Beetle Induced Tamarisk Defoliation In The Lower Virgin River Using Satellite Based Surface Energy Balance

    … Evapotranspiration at High Resolution with Internal Calibration (METRIC) land surface energy balance model was used to estimate Lower Virgin River riparian ET. METRIC ET results were compared with eddy covariance ET estimates made in tamarisk along the Lower Virgin River. Comparisons …

    unr Repository record for Reduced Evapotranspiration From Leaf Beetle Induced Tamarisk Defoliation In The Lower Virgin River Using Satellite Based Surface Energy Balance (opens in a new tab)

  14. GOES-R Supervised Machine Learning

    … behavior and position of the GOES-17. This calibration issue occurs when the LHP instrument fails to radiate the heat of the sun out of ABI. Predictive Calibration (pCal) is an algorithm developed by instrument vendors for the National Oceanic Atmospheric Agency (NOAA) to correct the …

    cuny Repository record for GOES-R Supervised Machine Learning (opens in a new tab)

  15. Greenhouse Gas Production and Nutrient Reductions in Denitrifying Bioreactors

    … studies. This work demonstrates the viability of internal calibration with gaseous standard addition to make dissolved gas analysis more robust to variable sample processing and to correct for matrix effects on gas partitioning that may occur in environmental samples.

    vt Repository record for Greenhouse Gas Production and Nutrient Reductions in Denitrifying Bioreactors (opens in a new tab)

  16. Natural Organic Matter Characterization and Lead Speciation as Indicators of Potential Lead Bioavailability in Aquatic Environments

    … Pb ion-selective electrode (ISE) and an internal calibration method. To confirm that this method was applicable for trace-level analysis in NOM, ethylenediamine (EN) was used as a model ligand in both artificial freshwater (AFW) and artificial seawater (ASW), and the speciation modelled …

    wilfrid-laurier Repository record for Natural Organic Matter Characterization and Lead Speciation as Indicators of Potential Lead Bioavailability in Aquatic Environments (opens in a new tab) Download PDF for Natural Organic Matter Characterization and Lead Speciation as Indicators of Potential Lead Bioavailability in Aquatic Environments (opens in a new tab)

  17. NOVEL APPROACHES FOR QUANTITATIVE PROTEOMICS

    … of proteins of interest. The method employs an internal calibration curve using four isotopologue calibrants to establish a linear response within each sample, allowing for accurate determination of sample amounts using interpolation. These strategies are vital in elucidating the stoichiometry …

    jhu Repository record for NOVEL APPROACHES FOR QUANTITATIVE PROTEOMICS (opens in a new tab) Embargoed until 2027-12-01

  18. EXCITED STATE DYNAMICS AND SPECTROSCOPY OF AZABENZENES (PYRIDINE, PYRIDAZINE, TRANSIENT SPECIES)

    … estimated oscillator strength of (TURN)0.02. An internal calibration method has enabled reliable excited state extinction coefficients to be evaluated. The intersystem crossing process in pyridine has been shown to be in or very near the statistical limit. Pressure-dependent and nonexponential …

    rice Repository record for EXCITED STATE DYNAMICS AND SPECTROSCOPY OF AZABENZENES (PYRIDINE, PYRIDAZINE, TRANSIENT SPECIES) (opens in a new tab)

  19. Overcoming Challenges in Surface-Enhanced Raman Spectroscopic Detection: Approaches for Quantitative Analysis of Reaction Kinetics and Increased Confidence of Substance Identification

    … on a SERS-active probe functionalized with an internal calibration standard. As a result, despite significant variability in the absolute signal intensity, the self-calibrated relative signal intensity remained stable. The assay was verified by observing the SERS spectral shift throughout an …

    tamu Repository record for Overcoming Challenges in Surface-Enhanced Raman Spectroscopic Detection: Approaches for Quantitative Analysis of Reaction Kinetics and Increased Confidence of Substance Identification (opens in a new tab)

  20. Quantitative Bone Health Assessment Using Opportunistic CT

    … characterized, including the effects of internal calibration assumptions, reconstruction kernel selection, calibration strategy, and intravenous contrast enhancement. Collectively, these investigations demonstrated that opportunistic CT measurements are highly sensitive to acquisition and …

    calgary Repository record for Quantitative Bone Health Assessment Using Opportunistic CT (opens in a new tab)

Page 1 of 3