Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 15 of 15 for “"Internal contamination"”.

  1. Assessing internal contamination levels for fission product inhalation using a portal monitor

    … acquire data quickly and that is sensitive to internal contamination. The portal monitor TPM-903B was investigated for use in the event of a fission product release. A list of fission products released from a Pressurized Water Reactor (PWR) was generated and separated into two groups--Group 1 …

    gatech Repository record for Assessing internal contamination levels for fission product inhalation using a portal monitor (opens in a new tab)

  2. Evaluation of internal contamination levels after a radiological dispersal device using portal monitors

    … dispersal device (RDD), the assessment of the internal contamination level of victims is necessary to determine if immediate medical follow-up is necessary. Thermo Scientific's TPM-903B Portal Monitor was investigated to determine if it is a suitable first cut screening tool for internal …

    gatech Repository record for Evaluation of internal contamination levels after a radiological dispersal device using portal monitors (opens in a new tab)

  3. The use of a thyroid uptake system for assaying internal contamination following a radioactive dispersal event

    Assaying internal contamination due to inhalation is a primary concern in developing emergency procedures related to Radioactive Dispersal Devices (RDD). One method of determining internal contamination makes use of a common medical instrument, a Thyroid Uptake System (TUS). The TUS used in this …

    gatech Repository record for The use of a thyroid uptake system for assaying internal contamination following a radioactive dispersal event (opens in a new tab)

  4. Assessing internal contamination after a radiological dispersion device event using a 2x2-inch sodium-iodide detector

    … situation where many individuals are exposed to contamination due to the inhalation of radioactive materials. Assessments of contamination may need to be performed by emergency response personnel in order to triage the potentially exposed public. The feasibility of using readily available …

    gatech Repository record for Assessing internal contamination after a radiological dispersion device event using a 2x2-inch sodium-iodide detector (opens in a new tab)

  5. A comparison of three computational phantoms for calibration of a radiation portal monitor used for measurement of internal contamination.

    … to investigate if portal monitors could measure internally deposited radioisotopes over a short count time (1 second) with a detection limit sufficient to measure 1/10 of an annual limit on intake (ALI) of specific radionuclides. The goal was to determine if portal monitors in nuclear facilities …

    uoit Repository record for A comparison of three computational phantoms for calibration of a radiation portal monitor used for measurement of internal contamination. (opens in a new tab)

  6. Internal Dose Assessment Following a Postulated Accident at a Tungsten-Target Spallation Source : Modelling and Assessment of Inhaled Radionuclides

    This thesis investigates atmospheric dispersion, internal contamination monitoring, and biokinetic behaviour following inhalation of radionuclides released in a postulated loss-of-coolant accident at the European Spallation Source. The findings provide insight into the factors governing the …

    lund Repository record for Internal Dose Assessment Following a Postulated Accident at a Tungsten-Target Spallation Source : Modelling and Assessment of Inhaled Radionuclides (opens in a new tab) Download PDF for Internal Dose Assessment Following a Postulated Accident at a Tungsten-Target Spallation Source : Modelling and Assessment of Inhaled Radionuclides (opens in a new tab)

  7. ²²⁶Ra contamination of soil and foliage as a function of distance downwind from uranium mill tailings

    This study concerned 226Ra contamination of soils and foliage as a function of distance downwind from a uranium mill tailings pile. In soils the radium contamination was primarily associated with particle sizes < 0.045 mm and mainly found within the 0-0.6 cm soil horizon. The 0-0.6 cm soil horizon …

    colostate Repository record for ²²⁶Ra contamination of soil and foliage as a function of distance downwind from uranium mill tailings (opens in a new tab)

  8. Condensation of refrigerants on small tube bundles

    … for the finned tubes over the smooth tubes. Internal contamination, possibly due to a breakdown of the refrigerant molecules when subjected to high temperatures in the boiling chamber, inhibited further meaningful data collection. Recommendations for improvement of the test apparatus are made.

    nps Repository record for Condensation of refrigerants on small tube bundles (opens in a new tab)

  9. Analyzing a Canine in a Radioactive Contaminated Environment

    … positron emission tomography (PET) scanner both internal and external contamination from the dog was localized and quantified. Total contamination on the dog as quantified by the PET scan was 3.4 kBq with external and internal contamination being 2.1 kBq and 1.3 kBq, respectively. Total external …

    tamu Repository record for Analyzing a Canine in a Radioactive Contaminated Environment (opens in a new tab)

  10. Assessing the dose after a radiological dispersal device (RDD) attack using a military radiac instrument

    … are necessary to determine the level of contamination received in order to prioritize and treat individuals. The use of improvised explosive devices (IEDs) and the number of orphan sources in deployed and combat areas such as Iraq, present an opportunity for terrorists to use an RDD …

    gatech Repository record for Assessing the dose after a radiological dispersal device (RDD) attack using a military radiac instrument (opens in a new tab)

  11. Evaluation of water distribution system monitoring using stochastic dynamic modeling

    … were made under different regimes of external contamination applied to the tank, the pump station and at system nodes, and internal contamination representing biofilm effects based on assumed relationships between flow velocities and bioflim cell detachment. Seven sampling plans representing …

    vt Repository record for Evaluation of water distribution system monitoring using stochastic dynamic modeling (opens in a new tab)

  12. Control of viral contamination of reclaimed irrigated vegetables by drip irrigation

    … drip irrigation resulted in 99% less viral contamination of vegetable leaves as compared to surface drip irrigation. The greatest risk of infection occurs from the outer leaves of lettuce. The risk of infection from consumption of reclaimed wastewater irrigated tomatoes and cucumber was 32% …

    arizona-thes Repository record for Control of viral contamination of reclaimed irrigated vegetables by drip irrigation (opens in a new tab)

  13. Investigating the steam sterilization of dental handpieces

    … design and function of the dental handpieces, internal contamination of handpiece components frequently occurs during use, raising the risk of iatrogenic infection. Dental handpiece lumens represent a challenge for both cleaning and steam sterilization due to limited access. Manufacturers of …

    glasgow Download PDF for Investigating the steam sterilization of dental handpieces (opens in a new tab)

  14. A novel method for rapid in vitro radiobioassay

    Rapid and accurate analysis of internal human exposure to radionuclides is essential to the effective triage and treatment of citizens who have possibly been exposed to radioactive materials in the environment. The two most likely scenarios in which a large number of citizens would be exposed are …

    colostate Repository record for A novel method for rapid in vitro radiobioassay (opens in a new tab)

  15. Disinfection of fresh produce contaminated by enteric viruses and their inactivation mechanisms

    … However, hydroponically grown vegetables can be internally contaminated through the hydroponics feed water which may contain viruses. Sanitation of post-harvest vegetable with internalized viruses may not be effective because sanitizers might not be able to reach viruses internalized inside the …

    uiuc Repository record for Disinfection of fresh produce contaminated by enteric viruses and their inactivation mechanisms (opens in a new tab)