Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 19 of 19 for “"Internal fault"”.

  1. Modelling of three phase AC machines suitable for internal fault simulation, detection and analysis in multi-machine power systems

    … that undergo severe unbalanced operation due to faulty conditions developing anywhere in the power network, including the rotating machinery’s windings. To achieve an unrivalled speed of response, a nodal-based model of the electrical power network has been developed, enabling the study of power …

    glasgow

  2. Proteção diferencial de transformadores de potência baseada em máquinas de vetor de suporte e transformada wavelet

    … must work quickly and efficiently in cases of internal fault in the transformer, because depending on the severity of the fault can lead to the loss of the transformer. The differential function has been widely used in protection for power transformer, because it is a quick and selective …

    brazil-ufrn Repository record for Proteção diferencial de transformadores de potência baseada em máquinas de vetor de suporte e transformada wavelet (opens in a new tab)

  3. Ratios-Based Universal Differential Protection Scheme for Power Transformers

    … in power systems. It is subject to short circuit faults similar to any other component of the power system. Failure to detect these faults may result in transformer blaze and may subsequently lead to property damage. Therefore, transformer protection is of vital significance to provide reliable …

    calgary Repository record for Ratios-Based Universal Differential Protection Scheme for Power Transformers (opens in a new tab)

  4. ATP modeling of internal transformer faults for relay performance testing

    … Unfortunately, they are subjected to through-faults and abnormal operating conditions which can affect not only the transformer itself but also other equipment connected to the transformer. Thus, it is essential to provide sufficient protection for transformers as well as the best possible …

    mtu Repository record for ATP modeling of internal transformer faults for relay performance testing (opens in a new tab)

  5. FUZZY BASED UNIT PROTECTION SYSTEM FOR POWER TRANSFORMERS

    … Transient Program (ATP). Various kinds of faults were generated using the program and these include interwinding faults, three phase faults, phase to ground faults, phase to phase faults, primary to secondary faults, as well as, external faults. Inrush conditions and over-excitation were …

    nus Repository record for FUZZY BASED UNIT PROTECTION SYSTEM FOR POWER TRANSFORMERS (opens in a new tab) Download file for FUZZY BASED UNIT PROTECTION SYSTEM FOR POWER TRANSFORMERS (opens in a new tab)

  6. Protection of synchronous generators and induction generators

    … securely and dependably when they have internal faults. Specifically, the EBP function monitors the consistency between the generator measurements and the generator dynamic model via dynamic state estimation. Any mismatch between the measurements and the model indicates generator …

    gatech Repository record for Protection of synchronous generators and induction generators (opens in a new tab)

  7. Damage analysis of internal faults in flux concentrating permanent magnet motors.

    … simulation model to study the effects of an internal fault in a large permanent magnet ac synchronous motor. Permanent magnet motors are being considered as an alternative for ships with electric propulsion systems. In an electric propulsion system a large motor will be directly connected to …

    nps Repository record for Damage analysis of internal faults in flux concentrating permanent magnet motors. (opens in a new tab)

  8. The application of artificial neural networks to transformer protection

    … between transformer magnetizing inrush and fault currents. The proposed ANN-based inrush detector uses magnitudes of fundamental and up to the fifth harmonic components as the inputs and provides inrush or no-inrush indication to the differential relay. Some important issues such as the …

    ubc Repository record for The application of artificial neural networks to transformer protection (opens in a new tab) Download PDF for The application of artificial neural networks to transformer protection (opens in a new tab)

  9. Transnationalism, power and change: three decades of debt campaigning

    … TNCS is explored through an analysis of the internal fault lines along the south/north interface of those campaigns. The thesis is based on an analysis of debt campaign documents, interviews with key informants, media sources and secondary sources. It finds that debt campaigning challenged …

    dcu Download PDF for Transnationalism, power and change: three decades of debt campaigning (opens in a new tab)

  10. A Line-Commutated Thyristor-Bridge Emulated Rotating Power Electronic Converter for Brushless Exciter Applications

    … decay of the field current slow. In case of an internal fault in the synchronous machine, the field current needs to be removed rapidly. In this dissertation, a novel thyristor emulated rotating power electronic converter (RPEC) is proposed for brushless exciter (BLE) applications. In this …

    umn Repository record for A Line-Commutated Thyristor-Bridge Emulated Rotating Power Electronic Converter for Brushless Exciter Applications (opens in a new tab)

  11. Transformer Differential Protection Under Geomagnetically Induced Current Conditions

    … during the GMDs and remain blocked for the faults occurring in their protection zones, which may damage the transformers and threaten the system’s resiliency. This dissertation conducts in-depth time-domain analyses on the performance of differential relays, equipped with various HB logics, …

    york Repository record for Transformer Differential Protection Under Geomagnetically Induced Current Conditions (opens in a new tab)

  12. Renunciation and the Householder/Renouncer Relation in the New Kadampa Tradition

    … but also in some of the movement’s more visible internal fault lines: labour shortage, turnover, and disgruntled former members.

    waterloo Repository record for Renunciation and the Householder/Renouncer Relation in the New Kadampa Tradition (opens in a new tab)

  13. Transformer protection based on dynamic state estimation

    … the proposed research is to detect transformer internal faults or transformer overheating and trip the transformer, with immunity to external faults for which tripping of the transformer is not required. A new transformer protection scheme based on dynamic state estimation has been proposed. …

    gatech Repository record for Transformer protection based on dynamic state estimation (opens in a new tab)

  14. DEVELOPMENT OF THE COIL VOLUME METHOD FOR TIME-DOMAIN SIMULATION OF INTERNAL FAULTS IN TRANSFORMERS

    … power equipment, the transformer is subject to internal faults. The extent of transformer damage depends on the fault duration. Therefore, the protective relays should provide for sensitivity, selectivity, and speed of operation to minimize the effects of damaging conditions. High sensitivity of …

    mtu Repository record for DEVELOPMENT OF THE COIL VOLUME METHOD FOR TIME-DOMAIN SIMULATION OF INTERNAL FAULTS IN TRANSFORMERS (opens in a new tab)

  15. In Situ Compressional Wave Velocity Across An Exposed Brittle Fault Zone

    … mineralization on the geophysical properties of fault zones are not very well understood. In situ seismic data collected over the exhumed San Gregorio Fault at Moss Beach, CA were used to relate in situ compressional wave velocity to internal fault zone properties. This active strike-slip fault …

    vt Repository record for In Situ Compressional Wave Velocity Across An Exposed Brittle Fault Zone (opens in a new tab)

  16. Analysis and Design of Paralleled Three-Phase Voltage Source Converters with Interleaving

    … with paralleled VSCs under the occurrence of internal faults is studied. After the internal fault is detected and isolated, the paralleled VSCs system can continue work. So system reliability can be increased.

    vt Repository record for Analysis and Design of Paralleled Three-Phase Voltage Source Converters with Interleaving (opens in a new tab)

  17. Fault Discrimination Algorithm for Busbar Differential Protection Relaying Using Partial Operating Current Characteristics

    … (CT) saturation during close-in external faults. Researchers have suggested various solution of this problem; however, individually they are not sufficient to puzzle out all mis-operational scenarios. This thesis presents a new bus differential algorithm by defining alternative partial …

    uno Repository record for Fault Discrimination Algorithm for Busbar Differential Protection Relaying Using Partial Operating Current Characteristics (opens in a new tab)

  18. Cooperative Control of Multiple Unmanned Aerial Vehicles with Application to Forest Fire Detection and Fighting

    … mission. Furthermore, a new algorithm for fault-tolerant cooperative control (FTCC) is proposed, in order to mitigate potential UAV fault effect for reliable and safe mission completion. Finally, a fire fighting algorithm is developed for achieving minimum distances for forest fire UAVs to …

    concordia Download PDF for Cooperative Control of Multiple Unmanned Aerial Vehicles with Application to Forest Fire Detection and Fighting (opens in a new tab)