Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 22 for “"Internal heat exchanger"”
-
Role of internal heat exchanger in air conditioning systems
Internal heat exchangers (IHX) has been implemented into refrigeration and air-conditioning industry for a long time because of its ability to improve the efficiency of refrigeration cycles for several commonly used and potential substitution of refrigerants (R134a, R744 and R1234yf among them). It …
-
Internal Heat Exchanger Application in Heat Pumps: Evaluation and testing of different internal heat exchangers for efficiency improvement
A heat pump is a device which is an effective means of producing heat to satisfy heating and cooling demands for a building following the refrigeration cycle through transferring thermal energy from a colder region to a warmer region. This thesis is limited to explore options available in …
-
The performance of a reversible R744 vapor compression system with an internal heat exchanger in continuous frosting/ defrosting cycles
Submission published under a 24 month embargo labeled 'Closed Access', the embargo will last until 2024-08-01
-
Investigation of vapor injection heat pump system with a flash tank utilizing R410A and low-GWP refrigerant R32
… has proven to be effective in improving heat pump system performance, especially for cooling application at high ambient and heating application at low ambient temperature conditions. Recent research on vapor injection technique has been mostly focused on the internal heat exchanger cycle …
-
Performance and Oil Retention Characteristics of a CO2 Heat Pump Water Heater
A CO2 heat pump water heater (HPWH) was investigated experimentally and analytically. In the first stage of the study, a baseline performance was measured, investigating the effect of operating parameters on the system performance under typical tank heating scenarios. In the second, the CO2 HPWH …
-
A study of a transcritical multi-stage carbon dioxide heat pump
… reciprocating compressors in a transcritical CO? heat pump working in cooling and/or heating modes through the use of computer modeling. A detailed simulation model of a reciprocating compressor is combined with semi-detailed gas cooler, evaporator and internal heat exchanger models to produce …
-
Coupled Design Optimization of Compact Heat Exchangers in Aviation. A design study using a generalized heat exchanger model, computational fluid dynamics and Bayesian optimization
… in the integration of high-performance, compact heat exchangers. As the European Union aims to achieve net-zero emissions by 2050, hydrogen-powered gas turbine engines are a promising solution. Future civil and military engines will face increased thermal loads, necessitating the integration of …
-
Mathematical modelling and thermodynamic optimization of a CO2 heat pump cycle
… the use of CO2 in a one-stage and two-stage heat pump cycle for transportation purposes using an existing HCFC-based heat pump modified to work with CO2. Tests were conducted on this existing experimental CO2 heat pump setup at SP Technical Research Institute of Sweden in Borås, Sweden. A …
-
Experimental and Analytical Investigation of a Two-Phase Ejector Used for Expansion Work Recovery in a Transcritical R744 Air-Conditioning System
… R744) refrigeration cycle, the supercritical heat rejection pressure can be used to maximize the system performance. In addition, large throttling losses make R744 a suitable fluid for expansion work recovery. This study presents experimental and computational results obtained from a …
-
PERFORMANCE INVESTIGATION OF TWO-STAGE HEAT PUMP SYSTEM WITH VAPOR-INJECTED SCROLL COMPRESSOR
Heat pumps provide cooling in summers and heating in winters. It is inevitable that the capacity and COP of the heat pumps degrade significantly in the case of high ambient temperatures in summers and low ambient temperatures in winters, when the maximum capacity is desired. Refrigerant …
-
Improving Vapor Compression Cycle Efficiencies in Support of Conventional Refrigerant Phaseouts
… producing COP highest improvements of 60% and internal water supplied by the evaporator condensate producing COP highest improvements 38%. The second set of modifications investigated are based on installing at the evaporator inlet HRV units with resulting COP improvements of 25% and ERV units …
-
Design And Optimization Of Organic Rankine Cycle For Low Temperature Geothermal Power Plant
… was studied using twelve working fluids in base, Internal Heat Exchanger and turbine bleeding constrained and non-constrained configurations. R601a, R245ca, R600 showed highest first and second law efficiency in the non-constrained IHX configuration. The highest net power was observed for R245ca, …
-
Σχεδιασμός, ανάπτυξη και πειραματική μελέτη ηλιακού ψύκτη προσρόφησης συνεχούς λειτουργίας
… of the machine as well as the geometry of the internal heat exchanger. Finally, the coefficient of performance and the specific cooling power were calculated. The operating principle of an innovative optical system for the concentration of solar radiation was presented. The system is suitable …
-
Σχεδίαση και υπολογιστική προσομοίωση πρότυπης μηχανής Stirling: ανάλυση της ροής στον αναγεννητή και παραμετρική μελέτη
… (45 bar), rotational speed (2500 rpm), and heat intake and rejection temperatures (977 K and 288 K, respectively). The simulation was conducted using ANSYS Fluent software. Special emphasis was placed on the regenerator, a crucial component for the engine's efficiency. The regenerator …
-
ENERGY SAVINGS AND THERMAL COMFORT OF SEPARATE SENSIBLE AND LATENT COOLING AIR-CONDITIONING SYSTEMS
… energy-consuming devices, i.e. electric heaters, are often used to reheat the conditioned air in order to provide thermal comfort for the building occupants. Separate sensible and latent cooling (SSLC) AC systems are capable of providing better control of cooling at no extra overload in …
-
Experimental and numerical study of a water-to-water heat pump working with CO2
… a one-stage transcritical CO2 water-to-water heat pump is numerically and experimentally analyzed in the production of hot water for the applications of space heating and domestic hot water generation. Different configurations commonly used in the market are studied and compared for the same …
-
Hot water supply using a transcritical carbon dioxide heat pump : a thesis presented in fulfilment of the requirement for the degree of Master of Engineering at Massey University, Palmerston North, New Zealand
… to 60°C. Most hot water systems are electrically heated. Heat pumps using carbon dioxide (CO₂) in the transcritical heat pump cycle offer high potential for energy savings. The use of CO₂ also offers further benefits such high volumetric heating capacity, reduced environmental impact, good …
-
Potentials for COP increase in vapor compression systems
… subcooling and increase of relative size of heat exchangers (HXs). Regarding work recovery ejectors, experimental results showed that the COP of the ejector system increased between 8.2% and 14.8% when compared to a conventional expansion valve system operating with R410A. The two major …
-
Internally cooled desiccant wheel and desiccant wheel based air-conditioning system
… conventional desiccant wheels by constructing an internally cooled desiccant wheel, in which cooling water was brought into the supply section of the wheel to change the dehumidification process from adiabatic to an isothermal/semi-isothermal process. A literature review regarding desiccant …
-
Energieeinsparung in Kälteanlagen durch Kombination von thermostatischem Expansionsventil und innerem Wärmeübertrager
Die Erfindung der Kältemaschine macht es möglich, dass heute zu beliebiger Zeit Kälte in benötigter Menge und gewünschter Temperatur erzeugt werden kann. Aber für die Kälteerzeugung braucht man Antriebsenergie. Das Ziel dieser Doktorarbeit besteht darin, mit einer intelligenten Kombination von …
Page 1 of 2