Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 58 for “"Interstitial Flow"”
-
Selective matrix remodeling to increase interstitial flow in lymphedema
Lymphedema is a disease characterized by swelling resulting from the accumulation of fluid in the extracellular matrix (ECM) of the skin. In order to alleviate this swelling, the authors sought to selectively degrade certain hydrophilic molecules in the ECM called glycosaminoglycans (GAGs). GAGs …
-
Microfluidic Dual-Gel Cell Culture Model For Studying Cell Migration Under Controlled Interstitial Flow
Abstract Interstitial flow, the slow flux of fluid occurring in the interstitial space of the extracellular matrix (ECM), affects the migration of many cell types through individual and synergistic contributions of several biophysical and biochemical phenomena. Notably, interstitial flow is linked …
-
Microfluidics modelling of interstitial flow through a tumor and the study of tumor cell under dielectrophoresis
… are due to the metastatic spread of cancer. Interstitial pressure and flow within the tumor microenvironment have been identified to be influential in the metastatic spread of cancer. This study focuses on biophysical effect of interstitial pressure and flow on the detachment of MCF-7 cells …
-
Molecular and mechanical regulators of lymphatic biology
… in the mouse tail, we demonstrated that slow interstitial flow created by lymphatic drainage was necessary for lymphatic capillary organization. This novel model permitted the identification of spatial, temporal and chemical factors governing lymphangiogenesis. In contrast to the sprouting …
-
Microfluidic studies on flow manipulation to assist metastasis research
… and biochemical effects. Among these, interstitial flow resulted from the intratumoral environment has been proven to be one of the causes assisting the directions of cell detachment and migration in tumor environment. This detachment leads to circulating tumor cells (CTCs) in …
-
Estimating interstitial discharge and velocity in flow in riprap and gabion engineering applications
Interstitial flow is a difficult hydraulic process to measure and predict. Interstitial flow does not follow the same laws as seepage flow in small-grain media (i.e. Darcy's Law), because flow regimes in aggregate rock are often transitional or turbulent at a mild slope. Flow paths and local …
-
Application of Microfluidic Technology for Studying the Effects of Fluid Forces and Extracellular Matrix on Angiogenesis and Lymphangiogenesis
… we investigate the transmural interstitial flow-mediated sprouting angiogenesis of HUVECs in both collagen-only ECM and collagen/HA matrices. Our results suggested that the addition of HA into collagen matrix has significantly altered the microstructure, mechanical and transport …
-
Developing a 3D in vitro Model by Microfluidics
… and cell injection as well as controlling the interstitial flow through a syringe pump. To demonstrate the effectiveness of our model, we further examine the migration of the MDA-MB-231 breast cancer cells in the porous in vitro model in the presence of a concentration gradient of fetal bovine …
-
Development of a Vascularized Tumor-on-a-Chip for Modeling Directed Vasculogenesis in Colorectal Cancer
… the route of delivery and a therapeutic target. Interstitial flow is a primary cue for tumor-driven vessel formation, yet in most vascularized tumor-on-a-chip platforms it is imposed as a fixed operating condition and inferred from device geometry rather than measured within the tissue chamber. …
-
Engineering three-dimensional lymphatic vasculature on-chip through biochemical and mechanical stimulus
… of mechanical stimuli, more specifically interstitial flow, on the formation of lymphatic sprouts to which we observe a dependency on the synergistic stimulus from the presence of pro-angiogenic factors while inducing interstitial flow. In summary, these results elucidate the physiological …
-
Dendritic cell chemotaxis in 3D : new tools and insights
… by the biasing of self-secreted chemokine by interstitial flow [4, 5]. To answer the question of how these two mechanisms contribute to DC homing, a quantitative understanding of how cells respond to gradients and interstitial flow present in their physiological microenvironment is needed [6]. …
-
The Development of a Printable Device with Gravity-Driven Flow for Live Imaging Glioma Stem Cell Motility
… responses with and without the presence of interstitial flow. Interestingly, GSCs from a single patient are heterogeneous, displaying differences among sub-colonies derived from the same parental line. To study the motility of cells under flow, PDMS microfluidics are commonly used. …
-
A 3D microfluidic tumor model to study immune cell infiltration into solid tumors
… 3D tumor tissue, which can recapitulate the interstitial flow and gradient microenvironment. I utilize this device to create novel methods in quantifying NK cell infiltration and demonstrate the utility of this device for both infiltration and post-infiltration analysis.
-
The development and alignment of engineered microvasculature in fibrin gel
… and that this compaction improves lumen density. Interstitial flow provided an additional increase in lumen density. A mathematical model of fluid flow through engineered microvessels and a variety of image analysis methods were also developed.
-
Engineering the Extracellular Matrix with DNA-Based Devices for Biochemical and Biophysical Sensing Applications
… non-collagenous ECM. In addition, slowly moving interstitial flow through the ECM plays a major role in modulating cancer cell migration that may promote metastasis by redistributing morphogens, leading to chemotaxis, or through the activation of cell-surface mechanosensors, such as focal …
-
Vasculature and flow in microfluidic systems
… explores the integration of vasculature and flow in microfluidic Organ-on-a-Chip systems to create more physiologically relevant in vitro models. First, a pancreatic ductal adenocarcinoma model incorporating interstitial flow was developed, demonstrating that fluid dynamics contribute to …
-
Lymphangiogenesis in the Developing Zebrafish
… of this vascular network. Wediscovered normal interstitial flow patterns are critical for proper lymphatic vasculardevelopment. Experimentally increasing or decreasing the velocity of interstitial flow,via alterations in blood pressure, ablates the normal formation of the thoracic duct …
-
In vitro lymphatic endothelial morphogenesis : molecular vs. biophysical regulation
… response of lymphatic endothelium to flow conditions, thus indicating that the lymphatic endothelium plays an active role in regulating their drainage function. It has been previously shown in our lab that in vitro blood and lymphatic morphogenesis are differentially enhanced by …
-
Effects of dynamic environments on extracellular morphogen gradients
… subjected to dynamic conditions such as interstitial flow (IF). Despite the importance of the extracellular environment in signaling, very little is known regarding the effects of mechanical stresses and subtle interstitial flows. This thesis examines the role of IF on morphogen gradients …
-
Enhancement of fine particle deposition to permeable sediments
… using treatments that covered a wide range of flow, particle, and bed conditions. Specific treatments demonstrated large enhancements (up to eight times settling). Delivery of particles to the interface is important, but models based on delivery alone failed to predict the observed enhancement. …
Page 1 of 3