Results 1 to 20 of 38 for “"Intra aortic balloon"”
-
Automatic control of intra-aortic balloon pumping
… to victims of cardiogenic shock is the intra-aortic balloon pumping technique which utilizes a polyurethane balloon that is inserted through a femoral artery and advanced to a predetermined position in the descending aorta. The balloon is pneumatically driven and typically controlled so …
-
Control and monitoring of an intra-aortic balloon pump for cardiac assist
… of a system for controlling and monitoring the Intra-Aortic Balloon Pump is described. A narrow band-pass filter is used to reduce noise and limit the input to the detector to the spectrum within which the R-wave of an ECG signal lies. A safety circuit to prevent the heart pumping against an …
-
Kontrapulsacijos intraaortiniu balionėliu taikymas kardiochirurgijoje /
… cardiogenic shock is as high as 50–80%. Intra-aortic balloon counterpulsation has been used for many years for the management of cardiogenic shock and has shown good results. However, the SHOCK II trial, which was conducted before 2012, raised doubts about the effectiveness of this …
-
ΥΠΟΛΕΙΠΟΜΕΝΗ ΣΤΕΝΩΣΗ ΜΕΤΑ ΕΠΑΝΑΣΗΡΑΓΓΩΣΗ ΣΤΕΦΑΝΙΑΙΑΣ ΑΡΤΗΡΙΑΣ ΚΑΙ ΕΝΔΑΟΡΤΙΚΗ ΑΝΤΛΙΑ ΑΝΤΙΩΘΗΣΗΣ ΕΠΙ ΟΞΕΟΣ ΕΜΦΡΑΓΜΑΤΟΣ ΜΥΟΚΑΡΔΙΟΥ. ΠΕΙΡΑΜΑΤΙΚΗ ΜΕΛΕΤΗ
… OF THIS STUDY WAS TO EVALUATE THE EFFECT OF THE INTRA-AORTIC BALLOON PUMP FOR FURTHER LIMITATION OF THE INFARCT SIZE AFTER RECANALIZATION IN THE PRESENCE OF SEVERE RESIDUAL STENOSIS. THE PROTOCOL INCLUDED 5 GROUPS. IN GROUP 1 THE ANIMALS WERE SUBJECTED TO PROXIMAL LEFT ANTERIOR DESCENDING …
-
Microprocessor control of a combined assist system for the profound support of the failing heart
… mechanical circulatory assist methods such as intra-aortic balloon pumping are of little effectiveness in cases of severe ventricular failure. The proposed study is concerned with the development and testing, on a mock circulatory loop and in a series of dog experiments, of an automated …
-
Microcirculatory and Myocardial Physiology in Ischaemic Left Ventricualr Dysfunction
… infarction.<br/>METHODS<br/>Simultaneous intra-coronary pressure and Doppler flow assessment with wave intensity analysis performed to determine the energy flux in the coronary circulation was undertaken following percutaneous revascularization, in two distinct cohorts. Firstly, in a group …
-
Kardiogeninis šokas ir pagalbinės kraujotakos priemonės /
… selection of patients for these treatments. The intra-aortic balloon pump remains the most used device, despite unfavourable outcomes in trials. Newer devices, while providing better haemodynamic performance and more time to decide on treatment tactics, do not show a significant improvement in …
-
Kardiogeninis šokas: Kada naudoti pagalbinius prietaisus? /
… and has few complications. In clinical practice, intra-aortic balloon counterpulsation, short-term ventricular assist devices such as Impella, TandemHeart, and others, as well as extracorporeal membrane oxygenation system are used. Long-term support is provided by long-term ventricular assist …
-
An adaptive model of left-heart function
… volume, left-ventricular end-systolic volume and aortic load. The operation of this left-heart model is demonstrated by use of a simple aortic model in computer simulations. The potential of the modeling technique in general (and of the adaptive left-heart model in particular) for use as a …
-
Design and development of a combined cardiovascular assist system for support in severe ventricular failure
… testing of a ventricular assist system combining intra-aortic balloon pumping (IABP) with partial veno-arterial bypass (VABP), both pulsatile and nonpulsatile. A series of animal experiments was carried out after verification of the concept on a mock circulation. Although statistical significance …
-
Η επίδραση της παραορτικής αντλίας αντιώθησης (PULVAD) στη στεφανιαία ροή και στη ροή στις καρωτίδες σε χοίρειο μοντέλο οξείας καρδιακής ανεπάρκειας
… by reperfusion. PULVAD was driven by a standard intra-aortic balloon pump console. Pigs were instrumented with Millar catheter, sonomicrometry crystals and a Doppler flow probe placed around LAD and common carotid artery. Coronary and carotid blood flow were measured without and after brief (<60 …
-
Η επίδραση της ενδοαορτικής αντλίας αντιώθησης στη στεφανιαία ροή σε φυσιολογικό μυοκάρδιο και μετά από μακράς διάρκειας ισχαιμία: πειραματική μελέτη
… the changes in coronary blood flow induced by intra-aortic balloon pump (IABP) counterpulsation in normal and reperfused porcine myocardium. Methods: A 30-ml IABP was placed in the descending aorta of 14 open-chest pigs. Each pig underwent occlusion of the mid left anterior descending (LAD) …
-
Πειραματική (in vitro) και κλινική μελέτη της επίδρασης της αρτηριακής ενδοτικότητας στην άμεση απόδοση της ενδοαορτικής αντλίας αντιώθησης
… arterial compliance (AC) on the effectiveness of intra-aortic balloon counterpulsation (IABC) are lacking. Especially, data indicating this effect independently from blood pressure levels, heart rate and cardiac output do not exist. The main objective of the present study was to examine and …
-
Operative Myokardrevaskularisation nach Myokardinfarkt innerhalb von 48 Stunden
… were in preoperative CS, 35.9% required an intra-aortic balloon pump (IABP), and 26.8% were treated with inotropes or vasopressive medication. The median time from AMI to surgery was 10±4 hours. All patients received complete revascularization (overall number of grafts: 3.2±0.9; arterial …