Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 10 of 10 for “"Intra-Fraction motion"”
-
Adaptive proton radiation therapy via fast Monte Carlo dose calculation to correct for inter- and intra-fraction motion and geometry changes
… to take into account the patient respiratory motion by defining planning target volumes based on a 4DCT of the patient. Density overwrites considering water-equivalent-path-length to voxels across the 4DCT targets works best. Project 4 demonstrates an online algorithm that maintains IMPT plan …
-
Towards personalized PTV margins for external beam radiation therapy of the prostate
… on the analysis of population-based inter- and intra-fraction motion data. These methods do not consider the patient-to-patient differences in demographic or clinical presentation of patient specific factors (PSFs), such as age, weight, body-mass index, health and performance status, …
-
Operation, characterisation & physical modelling of unflattened medical linear accelerator beams and their application to radiotherapy treatment planning
… comfort and reducing problems associated with intra-fraction motion.
-
Incorporating Cardiac Substructures Into Radiation Therapy For Improved Cardiac Sparing
… neural network (U-Net) from deep learning. Intra-fraction motion due to respiration was then quantified. The inter-fraction setup uncertainties utilizing a novel MR-linear accelerator were also quantified. Treatment planning comparisons were performed with and without substructure inclusions …
-
3D imaging for brachytherapy patient and mold applicator positioning verification
… solution capable of submillimeter pre-treatment, intra and inter-fraction applicator positioning, and repeatability. This system can be used to continuously track the intra-fraction motion of the skin applicator with respect to the patient's anatomical surface to enhance treatment accuracy, …
-
Dosimetric Evaluation and Verification of Respiratory Motion Management System in Radiation Oncology
Respiratory caused intra-fraction motion is an important factor that can affect radiation treatment accuracy. Although the major effect of respiratory motion is in lung tumors, other tumor sites in thoracic and abdomen such as esophagus and liver cancer can also move significantly depending on …
-
Incorporating range uncertainty into proton therapy treatment planning
… dosimetric constraints, and meet them at every fraction. Plan robustness is a measure of deviation between the delivered dose distribution and the planned dose distribution. Due to the same characteristics that make protons advantageous, conventional means of using margins to create a Planning …
-
Development of an On-line Planning and Delivery Technique for Radiotherapy of Spinal Metastases
… patient setup at the treatment unit, patient motion during the on-line process represents the main source of geometric uncertainty for dose delivery. Spine intra-fraction motion was assessed on CBCT for a group of 49 patients treated with a palliative intent. The use of surface marker tracking …
-
Surface guided radiotherapy
… In turn, accurate patient localization and motion management becomes more important. Several image guidance systems are available for radiotherapy (RT), with 3-dimensional (3D) volumetric images with cone beam computed tomography (CBCT) as a gold standard. In recent years, surface imaging …
-
MSPT : Motion Simulator for Proton Therapy
… être grandement dégradés par les mouvements intra-fraction. Par conséquent, l'étude de méthodes d'atténuation ou d'adaptation est nécessaire. C'est pour cela, que nous avons développé un logiciel ”open-source” de calcul et d'évaluation de dose en 4D, MSPT (Motion Simulator for Proton …