Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 56 for “"Intravascular Ultrasound (IVUS)"”
-
Η χρήση του Ενδοαυλικού Υπερήχου-Intravascular Ultrasound (IVUS) στη μελέτη της έκπτυξης και σωστής εναπόθεσης των ενδοστεφανιαίων προθέσεων (stent) στις στεφανιαίες στενώσεις
Εισαγωγή: Ο ενδοαγγειακός υπέρηχος (IVUS) αποτελεί μία από τις πιο αξιόπιστες μεθόδους απεικόνισης του στεφανιαίου αυλού και έχει αναδειχθεί ως πολύτιμο εργαλείο απεικόνισης για την αξιολόγηση των στεφανιαίων αγγείων, επιτρέποντας την ακριβή μέτρηση των διαστάσεων του αυλού και του αγγειακού …
-
High frequency ultrasonic imaging of targeted microbubble contrast agents under controlled shear stress
… used to enhance image-contrast and therapy using ultrasound. Current developments of these agents include the targeting of microbubbles to attach to specific markers expressed on certain diseased cells. Inflamed areas of atherosclerosis associated with unstable plaque in arteries have been shown …
-
Validation and application of intravascular ultrasound in the study of percutaneous coronary intervention
Intravascular ultrasound (IVUS) is a relatively new method of imaging coronary arteries which has several advantages over contrast angiography in the accurate quantification of coronary lumen and vessel dimensions and assessment of atherosclerotic plaque. Experimentally, IVUS has so far provided …
-
Integrated Circuits Design for Emerging Medical Ultrasound Imaging System-on-a-chip
… integration of the front-end ASIC. Targeted for intravascular ultrasound (IVUS), two integrated SoCs for guidewire ultrasound imaging systems have been designed and fabricated. The presented approaches are equally applicable in other miniature probes, such as intracardiac echography (ICE) …
-
Arterial Calcification and the Clinical Implications on Stent Function
… with meshes inferred from patient specific intravascular ultrasound (IVUS) data, which defined the histological disease condition of the arteries. Combined with stent modeling, this platform is targeted at the development of virtual evaluation of stent performance in a specific arterial …
-
Three-dimensional quantitative coronary angiography and the registration with intravascular ultrasound and optical coherence tomography
… with intracoronary imaging devices, such as intravascular ultrasound (IVUS) and optical coherence tomography (OCT). The algorithms were integrated into prototype software packages that were validated at a number of clinical centers. The feasibility of using such software packages in typical …
-
Computational methods for atherosclerotic plaque characterization
… characterization methodologies using Intravascular Ultrasound (IVUS), Optical CoherenceTomography (OCT) and Computed Tomography (CT) images of coronary vessels. The research wasinitiated after studying the limitations of existing automated plaque characterization methodologies,applied …
-
Integrated electronics design for high-frequency intravascular ultrasound imaging
… for successful implementation of CMUT-based intravascular ultrasound (IVUS) imaging catheters to enable next generation imaging tools. Therefore, this research developed and implemented custom-designed electronic circuits and systems integrated with an IC compatible transducer technology for …
-
Geo-UNet: A Geometrically Constrained Neural Framework for Clinical-Grade Lumen Segmentation in Intravascular Ultrasound
Precisely estimating lumen boundaries in intravascular ultrasound (IVUS) is needed for sizing interventional stents to treat deep vein thrombosis (DVT). Unfortunately, current segmentation networks like the UNet lack the precision required for clinical adoption in IVUS workflows. This arises due to …
-
Multi-Frequency Processing for Lumen Enhancement with Wideband Intravascular Ultrasound
The application of high frequency ultrasound is the key to higher resolution intravascular ultrasound (IVUS) images. The need to further improve the IVUS spatial resolution may drive the transducer center frequency even higher than the current 40 MHz range. However, increasing the center frequency …
-
Miniaturised All-optical Devices for Therapy and Ultrasound Imaging in Minimally Invasive Surgery
Optical ultrasound (OpUS) is an emerging imaging paradigm that exhibits high imaging resolution, immunity to electromagnetic interference, and ease of miniaturisation. The use of optical fibres permits therapeutic and imaging modalities to be integrated into devices with small lateral dimensions, …
-
A Semi-Supervised Statistical Framework and Generative Snakes for IVUS Analysis
… to medical image analysis, in particular to Intravascular Ultrasound (IVUS) tissue segmentation and characterization. This work also studies the tissue characterization problem in IVUS images and defines a new framework for automatic plaque recognition.
-
Application of intravascular ultrasound in the treatment of diffuse coronary artery disease /
… tools such as fractional flow reserve (FFR) and intravascular ultrasound (IVUS) enable the optimization of interventions, frequently enhancing their efficacy and reducing the risk of adverse events in the long term. However, the optimal PCI optimization strategy remains unclear, given the lack of …
-
Relationship Between Intravascular Ultrasound Parameters and Fractional Flow Reserve in Intermediate Coronary Artery Stenosis of Left Anterior Descending Artery
… study was to assess the relationship between intravascular ultrasound (IVUS) parameters, including volumetric analysis, and fractional flow reserve (FFR). METHODS: Both IVUS and FFR were performed in 206 cases of intermediate stenosis of the left anterior descending artery (LAD). Myocardial …
-
Beyond Conventional Stereotaxic Targeting: Using Multiplanar Computed Tomography, Optical Coherence Tomography and Intracranial/Extravascular Ultrasound of the Subarachnoid Space to Locate the Rhesus Vestibular Nerve for Single Unit Recording
… and an intracranial/cisternal adaptation of intravascular ultrasound (IVUS) as adjuncts to facilitate targeting the rhesus vestibular nerve. Image guidance using CT scans acquired after recording chamber implantation proved to be a simple and useful complement to traditional atlas-based …
-
Μελέτη της ευάλωτης αθηρωματικής πλάκας. Ανίχνευση και απεικόνιση με τεχνικές του ενδοστεφανιαίου υπερηχογραφήματος
… contrast agents, which have been used for intravascular imaging, can be used to trace neovascularization. The aim of the study was to detect and evaluate the density of neovascularization in non-culprit coronary atherosclerotic plaques of patients with stable angina or an acute coronary …
-
Malperfusion Syndrome in the Setting of Type A Aortic Dissection
… to assess the feasibility and safety of using intravascular ultrasound (IVUS) to assess and early diagnose MPS in the setting of TAAD. Results:The mortality of TAAD ranges from 17% to 31%, with a third of patients presenting with MPS. Mortality of TAAD patients increases significantly in the …
-
Combined intravascular ultrasound and photoacoustic imaging
… of the work was to evaluate the capability of intravascular photoacoustic (IVPA) imaging in combination with intravascular ultrasound (IVUS) to detect and differentiate atherosclerotic plaques. The composition rather than structural narrowing of the arteries is a major indicator of the …
-
Biomechanical and morphological characterization of common iliac vein remodeling: Effects of venous reflux and hypertension
… inflation-extension protocol in conjunction with intravascular ultrasound (IVUS) was utilized to investigate the passive biomechanical response of both control common iliac veins (from 9 dogs) and common iliac veins subjected to chronic venous reflux and hypertension (from 9 dogs). The change in …
-
Ultrasound Transducer Arrays for Risk Stratification in Coronary Artery Disease
… percutaneous coronary intervention (PCI). Intravascular ultrasound (IVUS) imaging is used to provide anatomical (morphological) imaging during PCI. However, current side-viewing IVUS does provide imaging of physiology and must cross the lesion in order to image it. Alternatively, …
Page 1 of 3