Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 95 for “"Ion Chamber"”
-
Design and optimization of 6li neutron-capture pulse mode ion chamber
… inexpensive 6Li neutron-capture pulse-mode ion chamber (LiPMIC) for neutron detection that overcomes the fill-gas contamination stemming from outgas of detector components. This research also provides a demonstration of performance of LiPMICs. Simulations performed with GARFIELD, a …
-
Monte Carlo study of ion chamber response in low energy photon beams
192Ir is one of the most popular radiation sources used for brachytherapy treatments. However, 192Ir emits a wide photon spectrum (10 keV to 900 keV) which impedes the creation of an 192Ir primary standard. The 192Ir air kerma calibration factor is derived by interpolating between 60Co, 137Cs and …
-
Examination of Ionization in Cesium Diode Pumped Alkali Lasers with an Ion Chamber Diagnostic
… leading candidates for future high power applications, with many potential utilities for the military, aerospace, communications, and scientific diagnostics. A critical step in their development is measurement and understanding of unwanted ionization processes that occur inside the laser, which …
-
Experimental and computational investigation of water-to-air stopping power ratio for ion chamber dosimetry in carbon ion radiotherapy
… This work aims at improving the accuracy of ion chamber dosimetry for particle therapy with carbon ion beams. The readout of air-filled ionization chambers is affected by a number of correction factors, some of which are known only with limited accuracy. This study deals with one of this beam …
-
COMMISSIONING OF ELECTRON BLOCKS IN MONACO AND DIODE CORRECTION FACTORS
… TPS Monte Carlo electron beam dose calculation model for electron treatment planning. The primary goals are to commission electron blocks and establish correction factors for diode measurements with the use of ion chamber output as references, improving dosimetric procedures and adhering to …
-
Dose verification of a stereotactic IMRT treatment planning system
In this project, ion chamber measurement and film dosimetry were used to verify dose distributions for a new stereotactic IMRT (Intensity Modulated Radiation Therapy) treatment planning system. This technique combines the principles of stereotactic radiosurgery and IMRT to significantly increase …
-
Lateral electron disequilibrium in radiation therapy
The radiation dose in radiation therapy is mainly measured by ion chamber. The ion chamber measurement will not be accurate if there is not enough phantom material surrounding the ion chamber to provide the electron equilibrium condition. The lack of electron equilibrium will cause a reduction of …
-
Developing a QA procedure for gated VMAT SABR treatments using 10 MV beam in flattening-filter free mode
Respiratory gating limits the radiation to a specific part of the breathing cycle and reduces the size of the Planning Target Volume (PTV). This thesis describes a novel quality assurance method for amplitude gating of Stereotactic ABlative Ra- diotherapy (SABR) treatments of liver delivered using …
-
Kilo-Voltage X-Ray Correction Factors for In-Water Measurements Based on TG-61
… an in-water measurement which is based on ionization chambers calibrated in air in terms of air kerma. The variation of the overall correction factor (PQ;cham) and its components (known as corrections for the change in the chamber response due to the change in the spectrum distribution in …
-
Charged Particle Transport in Magnetic Fields in the EGSnrc Monte Carlo Code System
The advent of magnetic resonance guided radiation therapy provides a promising technology for dealing with tumour motion and anatomical variations during treatment. These machines possess a variety of beam energies, geometrical configurations, and different magnetic field strengths. Although photon …
-
The disintegration of neon by fast neutrons
… bombarded with 2.68 Mev. neutrons from the reaction H²(dn)He³ . A gridded ion chamber, with 1 litre sensitive volume, filled with neon to 6¼ atmospheres pressure, was used to detect disintegrations. Pulses from the ion chamber were amplified, arid recorded on an 18-channel kicksorter. The …
-
Dosimetric properties of a prototype high field parallel MRI-Linac
… goal of treating a patient. Accurate determination of dose is required to ensure good patient outcomes and minimise the potential of harmful side effects from radiotherapy treatments. For MRI-linacs, the magnetic field can impact both the dose deposition and the ion chamber response, …
-
An Evaluation of The Consistency of Imrt Patient-Specific Qa Techniques
… the integrity of an intensity modulated radiation therapy (IMRT) treatment, each plan must be validated through a measurement-based quality assurance (QA) procedure, known as patient specific IMRT QA. Many methods of measurement and analysis have evolved for this QA. There is not a standard …
-
Studies of alpha-radioactivity in the marine environment
This dissertation deals with the alpha-radioactivity in the marine environment around South Africa, and the published literature relating to alpha-emitting nuclides in sea water and in marine organisms is surveyed in Chapter 1. As a first step in the investigation, the total alpha-activity of some …
-
Optimizing Of Spoiler Thickness For Total Body Irradiation (TBI) Utilizing Tomotherapy Technology
Delivering total body irradiation (TBI) with a Tomotherapy unit presents a unique challenge: minimizing lung dose while achieving a high skin dose. Acrylic spoilers offer a potential solution by slightly attenuating the incident photon beam, and therefore, reduce the lung dose. The spoilers can …
Page 1 of 5