Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 337 for “"Ion Chromatography"”.
-
Development of fast ion chromatography
Fast ion chromatography has been applied to short (3 cm) silica based ODS columns with a view to achieving rapid determinations of selected inorganic anions. The use of smaller stationary phase particle sizes (3 |im) allowed higher flow rates (2.0 - 2.5 ml/min) to be used while maintaining …
-
Methods Development for Ion Chromatography
Ion chromatography (IC) as developed by Small et. al. in 1975 has become an efficient and reliable analytical technique for simultaneous analysis of multiple ions in solution. The principle requirement prior to use the IC for an analysis is sample preparation; these include sample decomposition, …
-
Ion Chromatography And Ion Chromatography-High Resolution Mass Spectrometry Technologies For The Analysis Of Low-Order Explosive Residues
… of chromatographic methods for the detection of low molecular weight organic acids and inorganic anions found in low-order explosive residues are presented. The work is divided into six sections. Firstly, Chapter 1 provides a background on low-order explosives and fingermarks. Existing …
-
Electrodialytic membrane eluent generators and suppressors for ion chromatography
… published a scientific paper entitled "Novel Ion Exchange Chromatographic Method Using Conductimetric Detection."^ The use of ion exchange resins to separate a variety of ions, both positive and negative, had been in use for years on a preparative scale in the separation of metals, …
-
Ion Chromatography of Soluble Cr(III) and Cr(VI)
Ion chromatography coupled with a conductivity detector was used to investigate the analysis of Cr(III) and Cr(VI) in aqueous samples. An IC methodology for Cr(III) was developed using a cation column and an eluent containing tartaric acid, ethylenediamine, and acetonitrile at pH 2.9. The detection …
-
Next generation stationary phases for high performance chelation ion chromatography
… dedicated to the development and characterisation of novel stationary phases for the detection and separation of metal cations in high performance chelation ion chromatography (HPCIC). Standard ion exchange chromatography is often unsuitable for the analysis of metals in complex samples as the …
-
Ion chromatography with low-capacity resins and low-conductivity eluents
<p>Strong-base anion exchangers with capacities ranging from 0.04 to 1.46 mequiv./g and from 0.0016 to 0.024 mequiv./g are prepared from Amberlite XAD resins. Distribution ratios of common inorganic and organic anions decrease with decreasing resin capacity, but selectivity coefficients are …
-
Investigation of electrostatic ion chromatography for the separation of inorganic ions
The new technique of ‘electrostatic ion chromatography’ (ion chromatography using a zwittenomc stationary phase) has been applied to the separation of ions using pure water as an eluent, without the addition of any inorganic buffers or organic modifiers. The nature of the separation, le cationic or …
-
Development of low-pressure ion chromatography for the separation of anions
Ion chromatography on short permanently coated monolithic columns has been investigated with the aim of developing a low-pressure chromatographic method for the separation of inorganic anions. Both lon-chromatography and anion-exchange chromatography were studied as were three modes of detection …
-
Development of complexation ion chromatography for the determination of metal ions
A simple ion chromatographic method was developed for the determination of Pb(II) in river and polluted water samples. The method was based upon the use of a colourforming complexing eluent and direct visible detection of the eluting Pb(II) complex. Using the combination of a strong cation exchange …
-
Investigation Of High Performance Chelation Ion Chromatography For Trace Metal Determinations
A high performance chelation ion chromatography system using chelating dye-coated columns for the determination of trace metals in several high ionic strength matrices is described. Spectrophotometric detection using 4-(2-pyridylazo) resorcinol (PAR) / zinc-EDT A and Pyrocatechol Violet post-column …
-
Study Of Trace Element Determination By Ion Chromatography With Chemiluminescence Detection
… development of several highly sensitive liquid chromatography post-column reaction detectors based on chemiluminescence (CL) for the ion chromatography (IC) determination of metal species in a range of sample types. The first chapter describes a non-selective multi-element CL detector based on …
-
Development and characterisation of monolithic silica stationary phases for ion chromatography
… monolithic HPLC columns have received much attention in recent years, particularly those modified for reversed-phase separations. However, for ionexchange, silica based monolithic columns have received only limited attention. Therefore, the aim of this work was the development and characterisation …
-
Methods Development for Simultaneous Determination of Anions and Cations by Ion Chromatography
… this research is concerned is the determination of inorganic anions and cations with single injection ion chromatography. Direct detection of the separated analyte ions occurs after the analyte ions have passed through ion-exchange resins where they are separated according to their affinity …