Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 20 for “"Ion Mobility Spectrometer"”.
-
Towards the Development of a Prototype Ion Mobility Spectrometer
Ion mobility spectrometry (IMS) is an analytical technique that separates ions in the gas-phase based on differences in their mobility under the influence of an electric field. In traditional drift-tube IMS systems, an axial DC electric field pushes ions through a static bath gas, and the different …
-
A Gas Sampling Module for a Subsurface Ion Mobility Spectrometer
… was designed for use with a small subsurface ion mobility spectrometer (IMS) sensor system to extract soil gas samples from unsaturated soil (i.e., soil in which there are both gases and liquids in the void spaces) and inject these samples into the IMS. The sampling module, IMS, and …
-
Fabrication of a Miniature Ion Mobility Spectrometer in Low Temperature Co-Fired Ceramics
… methodology and the processing for fabrication of MEMS devices in LTCC. To demonstrate the capabilities of Ceramic MEMS, an Ion Mobility Spectrometer (IMS) sensor was designed and fabricated using Low Temperature Co-Fired Ceramic (LTCC) materials. The IMS measures the time of flight of an …
-
Development and fundamental characterization of a nanoelectrospray ionization atmospheric pressure drift time ion mobility spectrometer
Drift time ion mobility spectrometry (DTIMS) is a rapid post ionization gas-phase separation technique that distinguishes between compounds based on their differences in reduced mass, charge and collisional cross-section while under a weak, time-invariant electric field. Standalone DTIMS is …
-
The Use of a Field Programmable Gate Array in a Compact Ion Mobility Spectrometer Sensor System for Subsurface Volatile Organic Compound Detection
… be harmful if they come in contact with our nation's drinking wells. In order to ensure that the level of contaminants meets the standards set by the Environmental Protection Agency (EPA), contaminated sites must be monitored. Current methods for monitoring subsurface groundwater contaminants …
-
Development of a variable-temperature ion mobility/ time-of-flight mass spectrometer for separation of electronic isomers
The construction of a liquid nitrogen-cooled ion mobility spectrometer coupled with time-of-flight mass spectrometry was implemented to demonstrate the ability to discriminate between electronic isomers. Ion mobility allows for the separation of ions based on differing cross-sections-to-charge …
-
Ion mobility and mass spectrometric investigations of organophosphates related to chemical warfare agents and pesticides
A commercial Ion Mobility Spectrometer that is designed to detect Chemical Warfare Agents (CWAs), is modified by the addition of a second ion gate, and connected to a commercial Ion Trap Mass Spectrometer (ITMS). The addition of the second gate allows selection of individual ion mobility peaks for …
-
Embedded System Design for Multi-Purpose Sensors to Detect and Analyze Environmental Contaminants
… State University researchers has been commissioned by the Environmental Protection Agency (EPA) to develop a Multi-purpose Sensor System to detect and analyze environmental contaminants remotely, in real time, and without using traditional time-consuming laboratory analytical methods [1]. As …
-
Development and application of an ion mobility spectometer - quadrupole mass spectometer instrument
… a technique to enhance the reliability of detection of threat agents such as compounds used for chemical warfare and explosives. This was to be done by using a combination of an ion mobility spectrometer (IMS) in tandem with a quadrupole mass spectrometer (QMS). When meeting these requirements, …
-
Advancements in coupling ambient plasma ionization and drift tube ion mobility spectrometry with mass spectrometry
… describes progress in the development of ambient ionization and ion mobility separation technologies coupled at the atmospheric pressure interface of modern mass spectrometers. The physiochemical forces governing ambient plasma-based ion source efficiency were thoroughly evaluated, with studies …
-
Gas Phase Structure Characterization of Host-Guest Systems Using Ion Mobility Spectrometry
This dissertation focuses on the investigation of gas-phase characteristics of cucurbituril host-guest systems using ion mobility spectrometry (IMS) and related techniques. Collision cross-sections (CCS) of alkylammonium complexes of cucurbit[n]uril (CB[n]) are measured to understand the allosteric …
-
Chemical Mixture Discrimination and Quantification Analysis Using Photothermal Cantilever Detection Spectroscopy and Machine Learning
Molecular identification of various components in a gas mixture has many immediate practical applications. Conventional techniques for such analysis include gas chromatography-mass spectrometer (GC-Mass Spec), Ion Mobility Spectrometer (IMS) Fourier Transform Infrared (FTIR) Spectroscopy, Near …
-
New Instrumentation and Methods for Studying Heterogeneous Vapor Uptake by Aerosol Particles Ranging In Size From One Molecule to 10nm
… of a vapor will often change in size and composition due to heterogeneous vapor uptake. The physics and thermodynamics of this phenomenon are not well understood for particles less than ~10 nm where traditional models using bulk properties begin to break down. Further, existing methods for …
-
Method Transfer for Gas-Chromatography Ion Mobility Spectrometry from Laboratory to Industrial Instrumentation
European Union and United Kingdom regulations promoting the use of more environmentally friendly industrial processes, such as the use of aqueous formulation rather than organic matrices, has facilitated the development of problematic biocontamination events during manufacturing. The current gold …
-
Design of Microstructured Conducting Polymer Films for Enhanced Trace Explosives Detection
The detection of trace amounts of explosive material is critical to national security. Ion mobility spectrometer (IMS)-based contact sampling continues to be a common method employed for the detection of explosives in high security checkpoint applications, such as airport security. In this process …
-
Laser Remote Sensing of Trace Chemical Species Using 10.6 μm CO<sub>2</sub> Laser Enhanced Breakdown Spectroscopy and Differential Absorption Lidar.
… remote sensing techniques related to the detection of trace chemical species were studied. In particular, a Differential-Absorption lidar (DIAL), a Laser-Induced-Breakdown Spectroscopy (LIBS) lidar, and a Raman lidar were studied. Several of the laser spectroscopic techniques that were used were …
-
Aerosol Ion Mobility based Techniques for the Improved Analysis of Chemical Mixtures
Particle and ion separations in the gas phase are typically based upon ion mobility (K), also often called the electrical mobility, or simply, the mobility. The mobility is the proportionality coefficient between the steady velocity a particle (charged) moves with and the magnitude of an applied …
-
Modeling and experimenting a novel inverted drift tube device for improved mobility analysis of aerosol particles
Ion Mobility Spectrometry (IMS) is an analytical technique for separation of charged particles in the gas phase. The history of IMS is not very old, and in this century, the IMS technique has grown rapidly in the advent of modern instruments. Among currently available ion mobility spectrometers, …