Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 65 for “"Ion optics"”.
-
Ion optics of the mass spectrometer ion source
The ion beam transmission efficiency of the ion source is an important factor in determining the sensitivity of a mass spectrometer. Vauthier (1955) has shown for a simple source that the transmission efficiency is very low. The present thesis examines the transmission efficiency of a more complex …
-
Miniature Ion Optics Towards a Micro Mass Spectrometer
This PhD dissertation reports the development of miniature ion optics components of a mass spectrometer (MS) with the ultimate goal to lay the foundation for a compact low-power micromachined MS (µMS) for broad-range chemical analysis. Miniaturization of two specific components a) RF ion traps and …
-
Ion optics calculations for the University of Manitoba cyclotron
… and common beamlines was made using the information gained. With the aid of a much more sophisticated beam transport program "TRANSPORT" all beamlines were studied at various energies. The scope of the study was extended to include the problem of beam extraction or stripping. Using recalibrated …
-
Immersed Finite Element Particle-In-Cell Simulations of Ion Propulsion
… algorithm was developed for plasma simulations involving complex boundary conditions. The new algorithm is based on the three-dimensional immersed finite element method which is developed in this thesis, and a modified legacy particle-in-cell code. The model also applies a new meshing …
-
Soft Landing Ion Mobility Mass Spectrometry: History, Instrumentation and an Ambient Pressure Application
… landing mass spectrometry has been used to land ions on surfaces to coat or otherwise alter them. Commercial soft landing instruments do not yet exist, and the physical phenomenon of soft landing has not yet been fully described. For future ion mobility soft landing research, the theory of ion …
-
Performance Measurements of a Radio Frequency Ion Thruster on Noble Gas Propellants
Radiofrequency Ion Thrusters are well suited to operating at a range of powers and are ideal candidates for scaling down for sub 100 W electric propulsion systems. Low power electric propulsion systems are an enabling technology for increased access to space for cubesats due to the low power …
-
The design & construction of a proton microprobe using a GE PETtrace cyclotron
The interaction of fast neutrons with nuclear materials is a topic of fundamental interest in nuclear engineering. Fast neutrons possess the ability to degrade, and in some cases destroy, materials used in nuclear reactor pressure vessels and core internals. Unfortunately, there are very few …
-
Extraction optics for ion beam generation in the ARIEL facility at TRIUMF
The proposed ion optics extraction geometry from ARIEL has been optimized based on simulations with Comsol. Geometrical parameters such as the acceleration gap and angle of the face of the vacuum chamber were studied in order to improve the beam 4-emittance and beam spot size. For geometries of …
-
Study of charge emission from Si and Ge irradiated by a KrF excimer laser
… main purpose was to investigate the charge emission from Si and Ge surfaces under KrF excimer laser irradiation. We proved that this charge should not interfere with functioning of the ion optics associated with the RISTRON, which requires the combination of RIS with a mass selector. Experimental …
-
High Depth Resolution Rutherford Backscattering Spectrometry with a Magnet Spectrometer: Implementation and Application to Thin Film Analysis
The High-resolution RBS (HRBS) endstation in CIBA offers thin film analyses with sub-nanometer resolution through a detection system which consists of a spectrometer magnet and a Micro-Channel Plate - Focal Plane Detector (MCP-FPD) assembly. In this thesis, analytical and numerical studies of the …
-
Performance and lifetime simulation of ion thruster optics
A simulation code, ffx, was developed to study various aspects of ion thruster optics. Information concerning sheaths, impingement limits, perveance, electric potential, charge exchange, and sputtering is covered. Electron backstreaming and pit and groove wear are discussed in detail as two grid …
-
Ionospheric Simulator (IonSim): Simulating Ionospheric conditions in a vacuum chamber
Understanding and improving ionospheric models is important for both military and civilian purposes. This understanding improves prediction of radio propagation used for communication and GPS navigation. Various space-borne instruments, such as retarding potential analyzers (RPAs) and ion traps are …
-
A suprathermal ion accelerator
To facilitate calibration of the Rice ALSEP/SIDE instrument a low energy (thermal to 4.0 kev) positive ion beam of variable current density (10-12 to 10-8 amp/cm2) has been developed. A high perveance electron beam of 0.15 to 0.40 kev is formed using electrostatic lenses alone, without recourse to …
-
Numerical optimization of ion transport in electrospray mass spectrometry
Electrospray ionization (ESI) has developed into a key component of investigative analyses of samples in numerous biological, chemical, and geological contexts due to its unique ability to preserve the structure of ionized species without fragmentation. It is thus important that we fully understand …
-
Developing a spin polarized helium ion source for surface electronic structure studies
… spin polarized He$\sp+$ source for application in studies of electron spin correlations in ion neutralization at surfaces is described. The source is based on an optically pumped helium discharge. An rf discharge is used to produce metastable helium atoms in a clean pyrex glass cell. A 300 …
-
Development of an ion source for implantation of decaborane
Future generations of Si technology will require ultra shallow junctions (tens of nm) in the drain and source regions of MOS transistors. Fabrication of such shallow p-type junctions requires implantation of boron at ultra low energies ([identical to]1keV), below the limits of standard ion …
-
Plasma flow field measurements downstream of a hollow cathode
… cathode with the goal of identifying groups of ions and possible mechanisms of their formation within a plasma discharge that might cause erosion, especially with respect to the hollow cathode assembly. In space applications, hollow cathodes are used in electrostatic propulsion devices, …
-
Development of a novel titanium thermal ionization cavity source for electromagnetic radioisotope separation of samarium and other lanthanide isotopes
… and eventual deployment of next-generation medical diagnostic and cancer therapy tools. A radioisotope mass separator, located at the Missouri University Research Reactor (MURR) Center, was constructed to provide radioactive ion beams for the separation and production of high specific …
-
PHOTODISSOCIATION AND O(1D) REACTIONS OF NITROUS OXIDE
The focus of this dissertation is on the application of the velocity map imaging (VMI) technique to photodissociation and reaction dynamics. The multiplexing advantage of the VMI technique enables us to gather both angular and translational energy distributions simultaneously, with product quantum …
-
Numerical modeling of ion dynamics in a carbon nanotube field-ionized thruster
Carbon nanotube field ionization technology has the potential to make ion propulsion feasible for use in micro and nano-satellites. To better understand the phenomenon and optimize the ion thruster design, it is useful to have an accurate model of the system. Numerical modeling of large-scale …
Page 1 of 4