Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 37 for “"Ion-beam therapy"”
-
Scanned Ion Beam Therapy For Thoracic Tumors
… adolescents and young adults can develop radiation induced second cancers. These patients could potentially benefit from scanned ion radiotherapy yet likely would require motion mitigation strategies. In theory, four-dimensional (4D) optimization of ion beam fields for individual motion states …
-
Cyclotron Designs for Ion Beam Therapy with Cyclinacs
… separated-sector ) cyclotron designs for injection in CABOTO, a linac developed by the TERA Foundation delivering C6+/H2+ beams up to 400 MeV/u for ion beam therapy. This association of a variable energy linac injected by a fixed energy cyclotron is called cyclinac. Two superconducting cyclotron …
-
Applications for CMOS pixel sensors in ion-beam therapy
En hadronthérapie, des mesures de haute précision sont essentielles pour avoir une base de données robuste et délivrer le traitement prescrit au patient. Dans ce travail, un système de trajectométrie, composé de capteurs à pixels MIMOSA-28, a été utilisé pour différentes applications cliniques. …
-
Novel methods for treatment planning in Ion Beam Therapy
One of the biggest challenges in ion beam therapy is the mitigation of the impact of uncertainties in the quality of treatment plans. Some of the strategies used to reduce this impact are based on concepts developed decades ago for photon therapy. In this thesis novel methods and concepts, tailored …
-
4D offline PET-based treatment verification in ion beam therapy
… to the accessible sharp dose gradients, external beam radiotherapy with protons and heavier ions enables a highly conformal adaptation of the delivered dose to arbitrarily shaped tumour volumes. However, this high conformity is accompanied by an increased sensitivity to potential uncertainties, …
-
Investigation of a scintillating screen detector for ion beam therapy
Scanned heavy ion radiotherapy produces complex dose distributions, which have to be measured with high resolution in quality assurance. This work investigates a scintillating screen detector, originally developed for beam diagnosis, for fluence measurements at the Heidelberg Ion-Beam Therapy …
-
Nuclear prompt gamma spectroscopy for range verification in ion-beam therapy
Proton and heavier ions have a characteristic energy deposition profile presenting the maximum at the end of range of the primary particles. This feature potentially allows delivering highly conformal radiation therapy, depositing most of the dose in the target volume and sparing the healthy tissue …
-
MRI-only Stopping Power Ratio using Deep Learning for Ion-Beam Therapy Application
In ion beam therapy, stopping power ratio (SPR) is required for estimating the dose distribution and ion range. Currently, it is estimated in clinical routines using single-energy CT. SPR derived from single-energy CT leads to large uncertainties in the dose distribution, as no material-specific …
-
Motion Management for Carbon Ion Therapy at the Heidelberg Ion-Beam Therapy Center
In 2011, stereotactic body radiotherapy was introduced for the treatment of hepatocellular carcinoma at the Heidelberg Ion-Beam Therapy Center (HIT). Initially, thirteen patients were treated, including the first patient treated using respiratory beam gating. This thesis presents the work flow and …
-
Design study of a Compton camera for prompts-gamma imaging during ion beam therapy
… est une technique innovante de radiothérapie par ions carbone ou protons visant à améliorer les traitements actuels. La précision balistique accrue renforce la nécessité d'un contrôle du dépôt de dose, si possible en temps réel. Une manière de réaliser ce contrôle est de détecter avec une caméra …
-
Development and testing of a biologic dosimentric phantom for proton and ion beam therapy
… of clinical treatment protocols for particle therapy depends on the availability and quality of radiobiological data. Studying available commercial and in-house phantoms, showed that the current solutions either lack dosimetry or this dosimetry introduces uncertainties to the biological …
-
Low-dose ion-based transmission radiography and tomography for optimization of carbon ion-beam therapy
In the last few decades, ion-beam radiotherapy has emerged as a highly effective tumor treatment modality. Its success relies on the capability to precisely confine the prescribed dose within the target volume, due to the inverted depth-dose profile and the finite range featured by charged …
-
Improving ion beam therapy treatment planning for metal implants by using dual-energy CT scanning
One of the major uncertainties in ion beam therapy planning is the calculation of ion ranges in the patient’s tissue from CT images. The presence of non-tissue-equivalent mate- rials and materials with high photon attenuation like metals may aggravate this problem. Dual Energy Computed Tomography …
-
Design and implementation of a prompt-gamma camera for real-time monitoring of ion beam therapy
… des tissus sains. Cependant, la précision de l’irradiation s’avère également être le risque principal lors de l’utilisation de cette technique. En effet, une erreur dans la profondeur de pénétration des particules pourrait engendrer des dégâts considérables. A l’heure actuelle, aucune …
-
Positron emission tomography for the dose monitoring of intra-fractionally moving targets in ion beam therapy
Ion beam therapy (IBT) is a promising treatment option in radiotherapy. The characteristic physical and biological properties of light ion beams allow for the delivery of highly tumour conformal dose distributions. Related to the sparing of surrounding healthy tissue and nearby organs at risk, it …
-
Ion Spectroscopy for improvement of the Physical Beam Model for Therapy Planning in Ion Beam Therapy
Helium and carbon ions enable a more conformal dose distribution, narrower penumbra and higher relative biological effectiveness than photon and proton radiotherapy. However, they may undergo nuclear fragmentation in the patient tissues and the arising secondary fragments affect the delivered …
-
Treatment plan robustness in pancreatic patients treated with scanned ion-beam therapy: Inter- and intra-fractional aspects
… an unsolved oncological challenge, however radiotherapy with charged particles has been considered a promising approach to improve the patients overall survival. These patients might benefit from dose escalation, although uncertainties during the beam delivery (intra-fractional) or along the …
-
Towards the Clinical Application of Helium Ions at the Heidelberg Ion-Beam Therapy Center - Physical and Clinical Aspects
Long before the invention of current standard modalities such as intensity-modulated radiotherapy, helium ions were already incorporated clinically in the 1980s at the Lawrence Berkeley National Lab. At the onset of this research, although helium ion beams are available for pre-clinical experiments …
-
Assessment of linear energy transfer and relative biological effectiveness in proton-beam therapy and ion-beam therapy with Al2O3:C,Mg detectors
In proton-beam therapy (PBT) and ion-beam therapy (IBT), treatment fields exhibit nonhomogeneous linear energy transfer (LET) distributions, which can cause variations in the relative biological effectiveness (RBE). Although these quantities are taken into account during treatment planning, there …
Page 1 of 2