Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 16 of 16 for “"Ionization Gauge"”.

  1. Induced evaporation of metal from an aluminum surface by a normal pulse neodymium laser

    … ejected material was achieved by using a Hughes Ionization Gauge placed in the path of the ejected material. Oscilloscope traces of the ionization gauge output show that the gauge "sees" what is flying past it. There is good correlation between laser radiation, plasma radiation and ionization …

    nps Repository record for Induced evaporation of metal from an aluminum surface by a normal pulse neodymium laser (opens in a new tab)

  2. An apparatus for electron impact ionization cross-section measurements

    Cross sections for electron impact ionization of molecules and rare gases are necessary for the modeling of phenomena related to the earth's upper atmosphere and to plasmas. The construction of an apparatus to improve the accuracy of measurements of such cross sections is reported. The ions are …

    rice Repository record for An apparatus for electron impact ionization cross-section measurements (opens in a new tab)

  3. Fatigue Behavior of a Zirconium-Based Bulk Metallic Glass

    … tests in vacuum with and without the use of an ionization gauge seemed to indicate that the dissociation of the residual water vapor to atomic hydrogen in vacuum via a hot tungsten-filament ionization gauge could be a factor in the shorter fatigue lifetimes in vacuum than in air. Further testing …

    utk-theses Repository record for Fatigue Behavior of a Zirconium-Based Bulk Metallic Glass (opens in a new tab)

  4. Studies in gas chromatography and the reaction of methyl radicals with butene-1

    … of the eluents. A high-sensitivity ionization gauge detector for gas chromatography was developed. By keeping the grid potential below the ionization potential of helium the device is sensitive only to the eluted compounds in the gas stream. Sensitivities from 100 to 500 times …

    ubc Repository record for Studies in gas chromatography and the reaction of methyl radicals with butene-1 (opens in a new tab) Download PDF for Studies in gas chromatography and the reaction of methyl radicals with butene-1 (opens in a new tab)

  5. Enhancing Neutral Propellant Flow Uniformity in Hall Thrusters via Anode Design

    … performance. Uneven particle flux to the ionization region results in asymmetric thrust vectors, diminished propellant ionization, and decreased total efficiency. In this work, the gas density profiles within the ACME Hall thruster discharge channel were characterized for four unique anode …

    washington Repository record for Enhancing Neutral Propellant Flow Uniformity in Hall Thrusters via Anode Design (opens in a new tab)

  6. Progress towards a primary pressure standard with cold atoms

    … orifice flow standard is conducted via an ionization gauge which employed as a transfer standard.All measurement are carried out using Argon gas as the background gas of study.

    ubc Repository record for Progress towards a primary pressure standard with cold atoms (opens in a new tab) Download PDF for Progress towards a primary pressure standard with cold atoms (opens in a new tab)

  7. A study of the properties and applications of electrostatic charged particle oscillators

    … principle has also been applied as a thermionic ionization gauge and has been compared with other ionization gauges to pressures as low as 5 x 10- 11 torr.. This new gauge exhibited a number of advantages over most of the existing gauges. Finally the oscillator has been used in an evaporation ion …

    aston Download PDF for A study of the properties and applications of electrostatic charged particle oscillators (opens in a new tab)

  8. Development of a cold atom pressure standard

    … verified by comparing it with an N₂ calibrated ionization gauge traced back to an orifice flow standard. They agree within 0.5%. A complete uncertainty analysis of this cold atom pressure standard is provided here. Moreover, using this standard, we are able to observe and quantify the …

    ubc Repository record for Development of a cold atom pressure standard (opens in a new tab) Download PDF for Development of a cold atom pressure standard (opens in a new tab)

  9. Experimental speed distribution measurements and NHC self-assembly on Au(111)

    … on different physical principles, a hot-filament ionization gauge and a quartz crystal microbalance, were positioned directly above the spindle to detect transmitted atoms. The distribution of transmission measurements as a function of rotation speed is related to the speed distribution. This work …

    queens Repository record for Experimental speed distribution measurements and NHC self-assembly on Au(111) (opens in a new tab)

  10. Corrosion and corrosion fatigue behavior of a zirconium based bulk metallic glass

    … hydrogen in vacuum via a hot tungsten-filament ionization gauge could be a factor in the shorter fatigue lifetimes in vacuum than in air. In air, the fatigue endurance limit and the fatigue ratio for BMG-11 was found to be 907 MPa and 0.534, respectively. These values are much higher than those …

    ut-knoxville Repository record for Corrosion and corrosion fatigue behavior of a zirconium based bulk metallic glass (opens in a new tab)

  11. Design and optimisation of new beamlines for iThemba laboratory for accelerator based sciences (iThemba LABS)

    … MeV for protons. SPC1 uses an internal Penning Ionization Gauge (PIG) ion source that provides beams of light ions. SPC2 has two external ion sources; the polarized ion source and an electron cyclotron resonance (ECR) ion source, which provides beams of polarized hydrogen ions and heavy ions, …

    nwu-za Repository record for Design and optimisation of new beamlines for iThemba laboratory for accelerator based sciences (iThemba LABS) (opens in a new tab)

  12. Design and optimisation of new beamlines for iThemba laboratory for accelerator based sciences (iThemba LABS0

    … MeV for protons. SPC1 uses an internal Penning Ionization Gauge (PIG) ion source that provides beams of light ions. SPC2 has two external ion sources; the polarized ion source and an electron cyclotron resonance (ECR) ion source, which provides beams of polarized hydrogen ions and heavy ions, …

    nwu-za Repository record for Design and optimisation of new beamlines for iThemba laboratory for accelerator based sciences (iThemba LABS0 (opens in a new tab)

  13. Reduction of Rocket-Borne Atmospheric Density Measurements Using Monte Carlo Simulation

    … a supporting role to this mission, cold cathode ionization gauges recorded composite density along three rocket payload trajectory paths from 90 km to 200 km. Rocket-borne instruments experience near sonic to hypersonic velocities and encounter a range of viscous, slipflow, and collisionless flow …

    clemson Repository record for Reduction of Rocket-Borne Atmospheric Density Measurements Using Monte Carlo Simulation (opens in a new tab)

  14. Bezdrátový terminál

    Tato bakalářská práce popisuje základní principy měření plošné hmotnosti. Dále podává stručný přehled o dostupných bezdrátových technologiích používaných v průmyslu. Výsledkem této práce je návrh bezdrátového terminálu, který značně ulehčí kalibraci měřicích hlav ionizačního senzoru pro měření …

    brno-tech Repository record for Bezdrátový terminál (opens in a new tab)

  15. Development of high energy pulsed plasma simulator for plasma-lithium trench experiment

    … is mainly composed of a plasma gun for a preionization source, a theta pinch for heating, and guiding magnets for a better plasma transportation. Each component will be driven by capacitor banks and controlled by high voltage / current switches. Several diagnostics including triple Langmuir …

    uiuc Repository record for Development of high energy pulsed plasma simulator for plasma-lithium trench experiment (opens in a new tab)

  16. A major redesign of the University of Manitoba cyclotron and a study for axial injection of ions into the Princeton University AVF cyclotron

    … ions were provided by an internal PIG (Penning Ionization Gauge) [BEN69] source. Naturally, however, the research needs increasingly required higher beam intensity and energy as well as better beam quality. The development in the 1970s of an ECR (Electron Cyclotron Resonance) source [GEL79] …

    manitoba Repository record for A major redesign of the University of Manitoba cyclotron and a study for axial injection of ions into the Princeton University AVF cyclotron (opens in a new tab)